These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

244 related articles for article (PubMed ID: 31840145)

  • 1. CAD/CAM-fabricated removable partial dentures: a case report.
    Carneiro Pereira AL; Martins de Aquino LM; Carvalho Porto de Freitas RF; Soares Paiva Tôrres AC; da Fonte Porto Carreiro A
    Int J Comput Dent; 2019; 22(4):371-379. PubMed ID: 31840145
    [TBL] [Abstract][Full Text] [Related]  

  • 2. ACCURACY OF REMOVABLE PARTIAL DENTURE METAL FRAMEWORKS FABRICATED BY COMPUTER-AIDED DESIGN/ COMPUTER-AIDED MANUFACTURING METHOD: A SYSTEMATIC REVIEW AND META-ANALYSIS.
    Mai HY; Mai HN; Kim HJ; Lee J; Lee DH
    J Evid Based Dent Pract; 2022 Sep; 22(3):101681. PubMed ID: 36162896
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Virtual Evaluation of the Accuracy of Fit and Trueness in Maxillary Poly(etheretherketone) Removable Partial Denture Frameworks Fabricated by Direct and Indirect CAD/CAM Techniques.
    Negm EE; Aboutaleb FA; Alam-Eldein AM
    J Prosthodont; 2019 Aug; 28(7):804-810. PubMed ID: 31106495
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Use of intraoral scanning and 3-dimensional printing in the fabrication of a removable partial denture for a patient with limited mouth opening.
    Wu J; Li Y; Zhang Y
    J Am Dent Assoc; 2017 May; 148(5):338-341. PubMed ID: 28274480
    [TBL] [Abstract][Full Text] [Related]  

  • 5. An In Vitro Investigation of Accuracy and Fit of Conventional and CAD/CAM Removable Partial Denture Frameworks.
    Soltanzadeh P; Suprono MS; Kattadiyil MT; Goodacre C; Gregorius W
    J Prosthodont; 2019 Jun; 28(5):547-555. PubMed ID: 30407685
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of four CAD-CAM guides for preparing guiding planes of removable partial dentures.
    Bai H; Ye H; Chen H; Wang Y; Zhou Y; Sun Y
    Comput Biol Med; 2022 Jul; 146():105564. PubMed ID: 35569334
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Using Intraoral Scanning Technology for Three-Dimensional Printing of Kennedy Class I Removable Partial Denture Metal Framework: A Clinical Report.
    Hu F; Pei Z; Wen Y
    J Prosthodont; 2019 Feb; 28(2):e473-e476. PubMed ID: 29143451
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Clinical application of an intraoral scanner and CAD/CAM system for a Kennedy class I partially edentulous patient.
    Suzuki Y; Harada N; Watanabe KI; Maruo R; Shimpo H; Ohkubo C
    J Oral Sci; 2022 Jan; 64(1):109-111. PubMed ID: 34937814
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Advances in computer aided design and computer aided manufacturing of removable partial denture].
    Ma KN; Chen H; Ye HQ; Zhou YS; Wang Y; Sun YC
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2021 May; 56(5):485-490. PubMed ID: 33904285
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Accuracy of removable partial denture framework fabricated by casting with a 3D printed pattern and selective laser sintering.
    Tasaka A; Shimizu T; Kato Y; Okano H; Ida Y; Higuchi S; Yamashita S
    J Prosthodont Res; 2020 Apr; 64(2):224-230. PubMed ID: 31466919
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Manufacturing of an immediate removable partial denture with an intraoral scanner and CAD-CAM technology: a case report.
    Virard F; Venet L; Richert R; Pfeffer D; Viguié G; Bienfait A; Farges JC; Ducret M
    BMC Oral Health; 2018 Jul; 18(1):120. PubMed ID: 29973186
    [TBL] [Abstract][Full Text] [Related]  

  • 12. CAD/CAM technology for fabrication of reduction guide for RPD parallel guiding planes preparation: A dental technique.
    Carvalho Porto de Freitas RF; Carneiro Pereira AL; da Fonte Porto Carreiro A
    Prim Dent J; 2022 Dec; 11(4):66-70. PubMed ID: 36533369
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A novel digital altered cast impression technique for fabricating a removable partial denture with a distal extension.
    Wu J; Cheng Y; Gao B; Yu H
    J Am Dent Assoc; 2020 Apr; 151(4):297-302. PubMed ID: 32081301
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A systematic review of digital removable partial dentures. Part II: CAD/CAM framework, artificial teeth, and denture base.
    Takaichi A; Fueki K; Murakami N; Ueno T; Inamochi Y; Wada J; Arai Y; Wakabayashi N
    J Prosthodont Res; 2022 Jan; 66(1):53-67. PubMed ID: 33504722
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Fabrication of Zirconia Abutment Crown and Clasp Under Existing Removable Partial Denture Using CAD/CAM Technology.
    Tasaka A; Shimizu T; Hirabayashi T; Yamashita S
    Clin Cosmet Investig Dent; 2021; 13():421-427. PubMed ID: 34675685
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Novel fully digital workflow for removable partial denture fabrication.
    Nishiyama H; Taniguchi A; Tanaka S; Baba K
    J Prosthodont Res; 2020 Jan; 64(1):98-103. PubMed ID: 31229550
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Accuracy of CAD-CAM systems for removable partial denture framework fabrication: A systematic review.
    Carneiro Pereira AL; Bezerra de Medeiros AK; de Sousa Santos K; Oliveira de Almeida É; Seabra Barbosa GA; da Fonte Porto Carreiro A
    J Prosthet Dent; 2021 Feb; 125(2):241-248. PubMed ID: 32147252
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Preparing guiding planes for removable partial dentures: an in vitro comparison between assisted CAD-CAM template procedure and freehand preparation.
    Bai H; Ye H; Chen H; Wang Y; Zhou Y; Sun Y
    J Dent; 2022 Aug; 123():104166. PubMed ID: 35588921
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Removable partial dentures retained by hybrid CAD/CAM cobalt-chrome double crowns: 1-year results from a prospective clinical study: CAD/CAM cobalt-chrome double crowns: 1-year results.
    Herpel C; Springer A; Puschkin G; Zimmermann L; Stober T; Rammelsberg P; Schwindling FS
    J Dent; 2021 Dec; 115():103847. PubMed ID: 34678336
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Patient satisfaction with laser-sintered removable partial dentures: A crossover pilot clinical trial.
    Almufleh B; Emami E; Alageel O; de Melo F; Seng F; Caron E; Nader SA; Al-Hashedi A; Albuquerque R; Feine J; Tamimi F
    J Prosthet Dent; 2018 Apr; 119(4):560-567.e1. PubMed ID: 28709680
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.