BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

185 related articles for article (PubMed ID: 31843523)

  • 1. Low-kV coronary artery calcium scoring with tin filtration using a kV-independent reconstruction algorithm.
    Vingiani V; Abadia AF; Schoepf UJ; Fischer AM; Varga-Szemes A; Sahbaee P; Allmendinger T; Tesche C; Griffith LP; Marano R; Martin SS
    J Cardiovasc Comput Tomogr; 2020; 14(3):246-250. PubMed ID: 31843523
    [TBL] [Abstract][Full Text] [Related]  

  • 2. CT coronary calcium scoring with tin filtration using iterative beam-hardening calcium correction reconstruction.
    Tesche C; De Cecco CN; Schoepf UJ; Duguay TM; Albrecht MH; De Santis D; Varga-Szemes A; Lesslie VW; Ebersberger U; Bayer RR; Canstein C; Hoffmann E; Allmendinger T; Nance JW
    Eur J Radiol; 2017 Jun; 91():29-34. PubMed ID: 28629567
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Individualized coronary calcium scoring at any tube voltage using a kV-independent reconstruction algorithm.
    Vingiani V; Abadia AF; Schoepf UJ; Fischer AM; Varga-Szemes A; Sahbaee P; Allmendinger T; Giovagnoli DA; Hudson HT; Marano R; Tinnefeld FC; Martin SS
    Eur Radiol; 2020 Nov; 30(11):5834-5840. PubMed ID: 32468107
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Iterative beam-hardening correction with advanced modeled iterative reconstruction in low voltage CT coronary calcium scoring with tin filtration: Impact on coronary artery calcium quantification and image quality.
    Tesche C; De Cecco CN; Schoepf UJ; Duguay TM; Albrecht MH; Caruso D; Varga-Szemes A; Lesslie VW; Ebersberger U; Canstein C; Thilo C; Hoffmann E; Allmendinger T; Nance JW
    J Cardiovasc Comput Tomogr; 2017; 11(5):354-359. PubMed ID: 28756086
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Intraindividual Comparison of Dose Reduction and Coronary Calcium Scoring Accuracy Using Kilovolt-independent and Tin Filtration CT Protocols.
    Zook S; Tayal B; Kragholm K; Abdelkarim O; Tran D; Cocker M; Ramirez-Giraldo JC; Hallam K; Sexton C; Johnson S; Chang SM
    Radiol Cardiothorac Imaging; 2024 Jun; 6(3):e230246. PubMed ID: 38934769
    [TBL] [Abstract][Full Text] [Related]  

  • 6. High-pitch low-voltage CT coronary artery calcium scoring with tin filtration: accuracy and radiation dose reduction.
    Apfaltrer G; Albrecht MH; Schoepf UJ; Duguay TM; De Cecco CN; Nance JW; De Santis D; Apfaltrer P; Eid MH; Eason CD; Thompson ZM; Bauer MJ; Varga-Szemes A; Jacobs BE; Sorantin E; Tesche C
    Eur Radiol; 2018 Jul; 28(7):3097-3104. PubMed ID: 29404770
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Very low-dose coronary artery calcium scanning with high-pitch spiral acquisition mode: comparison between 120-kV and 100-kV tube voltage protocols.
    Marwan M; Mettin C; Pflederer T; Seltmann M; Schuhbäck A; Muschiol G; Ropers D; Daniel WG; Achenbach S
    J Cardiovasc Comput Tomogr; 2013; 7(1):32-8. PubMed ID: 23333186
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Prospective evaluation of the influence of iterative reconstruction on the reproducibility of coronary calcium quantification in reduced radiation dose 320 detector row CT.
    Choi AD; Leifer ES; Yu J; Shanbhag SM; Bronson K; Arai AE; Chen MY
    J Cardiovasc Comput Tomogr; 2016; 10(5):359-63. PubMed ID: 27591767
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Accuracy and Radiation Dose Reduction Using Low-Voltage Computed Tomography Coronary Artery Calcium Scoring With Tin Filtration.
    Tesche C; De Cecco CN; Vliegenthart R; Albrecht MH; Varga-Szemes A; Duguay TM; Ebersberger U; Bayer RR; Canstein C; Schmidt B; Allmendinger T; Litwin SE; Morris PB; Flohr TG; Hoffmann E; Schoepf UJ
    Am J Cardiol; 2017 Feb; 119(4):675-680. PubMed ID: 27986261
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Accurate Measurement of Agatston Score Using kVp-Independent Reconstruction Algorithm for Ultra-High-Pitch Sn150 kVp CT.
    Hu X; Tao X; Zhang Y; Niu Z; Zhang Y; Allmendinger T; Kuang Y; Chen B
    Korean J Radiol; 2021 Nov; 22(11):1777-1785. PubMed ID: 34431246
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Low-dose coronary calcium scoring CT using a dedicated reconstruction filter for kV-independent calcium measurements.
    Jubran A; Mastrodicasa D; van Praagh GD; Willemink MJ; Kino A; Wang J; Fleischmann D; Nieman K
    Eur Radiol; 2022 Jun; 32(6):4225-4233. PubMed ID: 34989838
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Finding the optimal dose reduction and iterative reconstruction level for coronary calcium scoring.
    Willemink MJ; den Harder AM; Foppen W; Schilham AM; Rienks R; Laufer EM; Nieman K; de Jong PA; Budde RP; Nathoe HM; Leiner T
    J Cardiovasc Comput Tomogr; 2016; 10(1):69-75. PubMed ID: 26342405
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Determining the radiation dose reduction potential for coronary calcium scanning with computed tomography: an anthropomorphic phantom study comparing filtered backprojection and the adaptive iterative dose reduction algorithm for image reconstruction.
    Blobel J; Mews J; Schuijf JD; Overlaet W
    Invest Radiol; 2013 Dec; 48(12):857-62. PubMed ID: 23917328
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Diagnostic efficacy of model-based iterative reconstruction algorithm in an assessment of coronary artery in comparison with standard hybrid-Iterative reconstruction algorithm: dose reduction and image quality.
    Ippolito D; Riva L; Talei Franzesi CR; Cangiotti C; De Vito A; Di Gennaro F; D'andrea G; Crespi A; Sironi S
    Radiol Med; 2019 May; 124(5):350-359. PubMed ID: 30539411
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Half-dose Coronary Artery Calcium Scoring: Impact of Iterative Reconstruction.
    Caruso D; De Santis D; Biondi T; Panvini N; Zerunian M; Rivosecchi F; Montesano M; Bellini D; Rengo M; Laghi A
    J Thorac Imaging; 2019 Jan; 34(1):18-25. PubMed ID: 30036296
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Radiation dose reduction for coronary artery calcium scoring at 320-detector CT with adaptive iterative dose reduction 3D.
    Tatsugami F; Higaki T; Fukumoto W; Kaichi Y; Fujioka C; Kiguchi M; Yamamoto H; Kihara Y; Awai K
    Int J Cardiovasc Imaging; 2015 Jun; 31(5):1045-52. PubMed ID: 25754302
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Approaches to ultra-low radiation dose coronary artery calcium scoring based on 3rd generation dual-source CT: A phantom study.
    McQuiston AD; Muscogiuri G; Schoepf UJ; Meinel FG; Canstein C; Varga-Szemes A; Cannao' PM; Wichmann JL; Allmendinger T; Vliegenthart R; De Cecco CN
    Eur J Radiol; 2016 Jan; 85(1):39-47. PubMed ID: 26724647
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Low radiation coronary calcium scoring by dual-source CT with tube current optimization based on patient body size.
    Dey D; Nakazato R; Pimentel R; Paz W; Hayes SW; Friedman JD; Cheng VY; Thomson LE; Slomka PJ; Berman DS
    J Cardiovasc Comput Tomogr; 2012; 6(2):113-20. PubMed ID: 22381663
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Adaptive Iterative Dose Reduction 3D Integrated with Automatic Tube Current Modulation for CT Coronary Artery Calcium Quantification: Comparison to Traditional Filtered Back Projection in an Anthropomorphic Phantom and Patients.
    Tang YC; Liu YC; Hsu MY; Tsai HY; Chen CM
    Acad Radiol; 2018 Aug; 25(8):1010-1017. PubMed ID: 29395796
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Coronary CT angiography with 80 kV tube voltage and low iodine concentration contrast agent in patients with low body weight.
    Andreini D; Mushtaq S; Conte E; Segurini C; Guglielmo M; Petullà M; Volpato V; Annoni A; Baggiano A; Formenti A; Bartorelli AL; Fiorentini C; Pepi M
    J Cardiovasc Comput Tomogr; 2016; 10(4):322-6. PubMed ID: 27357327
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.