These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

157 related articles for article (PubMed ID: 31845991)

  • 1. CALIBRATION OF A TABLETOP CONFOCAL MICROBEAM X-RAY FLUORESCENCE SPECTROMETER FOR A QUANTITATIVE DEPTH PROFILES EVALUATION.
    Prokeš R; Trojek T
    Radiat Prot Dosimetry; 2019 Dec; 186(2-3):268-273. PubMed ID: 31845991
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Laboratory-based micro-X-ray fluorescence setup using a von Hamos crystal spectrometer and a focused beam X-ray tube.
    Kayser Y; Błachucki W; Dousse JC; Hoszowska J; Neff M; Romano V
    Rev Sci Instrum; 2014 Apr; 85(4):043101. PubMed ID: 24784587
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Three-dimensional x-ray fluorescence mapping of a gold nanoparticle-loaded phantom.
    Ren L; Wu D; Li Y; Wang G; Wu X; Liu H
    Med Phys; 2014 Mar; 41(3):031902. PubMed ID: 24593720
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Energy response calibration of photon-counting detectors using x-ray fluorescence: a feasibility study.
    Cho HM; Ding H; Ziemer BP; Molloi S
    Phys Med Biol; 2014 Dec; 59(23):7211-27. PubMed ID: 25369288
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Depth profiling of element concentrations in stratified materials by confocal microbeam X-ray fluorescence spectrometry with polychromatic excitation.
    Wrobel P; Wegrzynek D; Czyzycki M; Lankosz M
    Anal Chem; 2014 Nov; 86(22):11275-80. PubMed ID: 25307861
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Reconstruction of confocal micro-X-ray fluorescence spectroscopy depth scans obtained with a laboratory setup.
    Mantouvalou I; Wolff T; Seim C; Stoytschew V; Malzer W; Kanngiesser B
    Anal Chem; 2014 Oct; 86(19):9774-80. PubMed ID: 25162502
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Depth elemental imaging of forensic samples by confocal micro-XRF method.
    Nakano K; Nishi C; Otsuki K; Nishiwaki Y; Tsuji K
    Anal Chem; 2011 May; 83(9):3477-83. PubMed ID: 21438498
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Application of confocal X-ray fluorescence micro-spectroscopy to the investigation of paint layers.
    Sun T; Liu Z; Wang G; Ma Y; Peng S; Sun W; Li F; Sun X; Ding X
    Appl Radiat Isot; 2014 Dec; 94():109-112. PubMed ID: 25151613
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A Monte Carlo (MC) based individual calibration method for in vivo x-ray fluorescence analysis (XRF).
    Hansson M; Isaksson M
    Phys Med Biol; 2007 Apr; 52(7):2009-19. PubMed ID: 17374924
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Application of Three Dimensional Confocal Micro X-Ray Fluorescence Technology Based on Polycapillary X-Ray Lens in Analysis of Rock and Mineral Samples].
    Li FZ; Liu ZG; Sun TX; Yi LT; Zhao WG; He JL; Peng S; Wang LL; Zhao GC; Ding XL
    Guang Pu Xue Yu Guang Pu Fen Xi; 2015 Sep; 35(9):2487-91. PubMed ID: 26669153
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Experimental demonstration of direct L-shell x-ray fluorescence imaging of gold nanoparticles using a benchtop x-ray source.
    Manohar N; Reynoso FJ; Cho SH
    Med Phys; 2013 Aug; 40(8):080702. PubMed ID: 23927295
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Confocal micro X-ray fluorescence analysis for the non-destructive investigation of structured and inhomogeneous samples.
    Heimler K; Gottschalk C; Vogt C
    Anal Bioanal Chem; 2023 Sep; 415(21):5083-5100. PubMed ID: 37482571
    [TBL] [Abstract][Full Text] [Related]  

  • 13. First demonstration of multiplexed X-ray fluorescence computed tomography (XFCT) imaging.
    Kuang Y; Pratx G; Bazalova M; Meng B; Qian J; Xing L
    IEEE Trans Med Imaging; 2013 Feb; 32(2):262-7. PubMed ID: 23076031
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Improvements in the calibration of 109Cd K x-ray fluorescence systems for measuring bone lead in vivo.
    Aro AC; Todd AC; Amarasiriwardena C; Hu H
    Phys Med Biol; 1994 Dec; 39(12):2263-71. PubMed ID: 15551552
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Application of confocal micro-beam X-ray fluorescence in nondestructive scanning analysis of the distribution of elements in a single hair].
    Liu HH; Liu ZG; Sun TX; Peng S; Zhao WG; Sun WY; Li YD; Lin XY; Zhao GC; Luo P; Ding XL
    Guang Pu Xue Yu Guang Pu Fen Xi; 2013 Nov; 33(11):3147-50. PubMed ID: 24555400
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Spectrometer for lanthanides' K x-ray fluorescence.
    Sakurai K; Mizusawa M; Terada Y
    Rev Sci Instrum; 2007 Jun; 78(6):066108. PubMed ID: 17614652
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Development of an attenuation correction method for direct x-ray fluorescence (XRF) imaging utilizing gold L-shell XRF photons.
    Ahmed MF; Yasar S; Cho SH
    Med Phys; 2018 Dec; 45(12):5543-5554. PubMed ID: 30307623
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Elemental imaging of trace elements in bone samples using micro and nano-X-ray fluorescence spectrometry.
    Streli C; Rauwolf M; Turyanskaya A; Ingerle D; Wobrauschek P
    Appl Radiat Isot; 2019 Jul; 149():200-205. PubMed ID: 31077976
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Determination of acid-resistant silicic particles in lung by micro-XRF and its application in diagnosis of drowning].
    Hu SL; Wen JF; Lai WB; Fang C; Zhang XT; Wang SC; Dai WL; Liu C
    Fa Yi Xue Za Zhi; 2010 Aug; 26(4):257-9. PubMed ID: 20967950
    [TBL] [Abstract][Full Text] [Related]  

  • 20. LabVIEW control software for scanning micro-beam X-ray fluorescence spectrometer.
    Wrobel P; Czyzycki M; Furman L; Kolasinski K; Lankosz M; Mrenca A; Samek L; Wegrzynek D
    Talanta; 2012 May; 93():186-92. PubMed ID: 22483897
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.