These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

262 related articles for article (PubMed ID: 31847555)

  • 1. Comparative Accuracy Analysis of a Real-time and an Intermittent-Scanning Continuous Glucose Monitoring System.
    Link M; Kamecke U; Waldenmaier D; Pleus S; Garcia A; Haug C; Freckmann G
    J Diabetes Sci Technol; 2021 Mar; 15(2):287-293. PubMed ID: 31847555
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of Point Accuracy Between Two Widely Used Continuous Glucose Monitoring Systems.
    Hanson K; Kipnes M; Tran H
    J Diabetes Sci Technol; 2024 May; 18(3):598-607. PubMed ID: 38189290
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A Three-Way Accuracy Comparison of the Dexcom G5, Abbott Freestyle Libre Pro, and Senseonics Eversense Continuous Glucose Monitoring Devices in a Home-Use Study of Subjects with Type 1 Diabetes.
    Jafri RZ; Balliro CA; El-Khatib F; Maheno MM; Hillard MA; O'Donovan A; Selagamsetty R; Zheng H; Damiano ER; Russell SJ
    Diabetes Technol Ther; 2020 Nov; 22(11):846-852. PubMed ID: 32453604
    [No Abstract]   [Full Text] [Related]  

  • 4. Performance and Usability of Three Systems for Continuous Glucose Monitoring in Direct Comparison.
    Freckmann G; Link M; Kamecke U; Haug C; Baumgartner B; Weitgasser R
    J Diabetes Sci Technol; 2019 Sep; 13(5):890-898. PubMed ID: 30730229
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The Accuracy of Continuous Glucose Sensors in People with Diabetes Undergoing Hemodialysis (ALPHA Study).
    Avari P; Tang W; Jugnee N; Hersi I; Al-Balah A; Tan T; Frankel AH; Oliver N; Reddy M
    Diabetes Technol Ther; 2023 Jul; 25(7):447-456. PubMed ID: 36961385
    [No Abstract]   [Full Text] [Related]  

  • 6. A new-generation continuous glucose monitoring system: improved accuracy and reliability compared with a previous-generation system.
    Christiansen M; Bailey T; Watkins E; Liljenquist D; Price D; Nakamura K; Boock R; Peyser T
    Diabetes Technol Ther; 2013 Oct; 15(10):881-8. PubMed ID: 23777402
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Accuracy of a Factory-Calibrated, Real-Time Continuous Glucose Monitoring System During 10 Days of Use in Youth and Adults with Diabetes.
    Wadwa RP; Laffel LM; Shah VN; Garg SK
    Diabetes Technol Ther; 2018 Jun; 20(6):395-402. PubMed ID: 29901421
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Measurement Performance of Two Continuous Tissue Glucose Monitoring Systems Intended for Replacement of Blood Glucose Monitoring.
    Freckmann G; Link M; Pleus S; Westhoff A; Kamecke U; Haug C
    Diabetes Technol Ther; 2018 Aug; 20(8):541-549. PubMed ID: 30067410
    [TBL] [Abstract][Full Text] [Related]  

  • 9. FreeStyle Libre and Dexcom G4 Platinum sensors: Accuracy comparisons during two weeks of home use and use during experimentally induced glucose excursions.
    Boscari F; Galasso S; Facchinetti A; Marescotti MC; Vallone V; Amato AML; Avogaro A; Bruttomesso D
    Nutr Metab Cardiovasc Dis; 2018 Feb; 28(2):180-186. PubMed ID: 29258716
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Performance of a Factory-Calibrated, Real-Time Continuous Glucose Monitoring System in Pediatric Participants With Type 1 Diabetes.
    Welsh JB; Zhang X; Puhr SA; Johnson TK; Walker TC; Balo AK; Price D
    J Diabetes Sci Technol; 2019 Mar; 13(2):254-258. PubMed ID: 30198331
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of Continuous Glucose Monitoring Accuracy Between Abdominal and Upper Arm Insertion Sites.
    Steineck IIK; Mahmoudi Z; Ranjan A; Schmidt S; Jørgensen JB; Nørgaard K
    Diabetes Technol Ther; 2019 May; 21(5):295-302. PubMed ID: 30994362
    [No Abstract]   [Full Text] [Related]  

  • 12. Performance of a Factory-Calibrated Real-Time Continuous Glucose Monitoring System Utilizing an Automated Sensor Applicator.
    Shah VN; Laffel LM; Wadwa RP; Garg SK
    Diabetes Technol Ther; 2018 Jun; 20(6):428-433. PubMed ID: 29923775
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A Prospective Multicenter Evaluation of the Accuracy of a Novel Implanted Continuous Glucose Sensor: PRECISE II.
    Christiansen MP; Klaff LJ; Brazg R; Chang AR; Levy CJ; Lam D; Denham DS; Atiee G; Bode BW; Walters SJ; Kelley L; Bailey TS
    Diabetes Technol Ther; 2018 Mar; 20(3):197-206. PubMed ID: 29381090
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of accuracy and safety of the SEVEN and the Navigator continuous glucose monitoring systems.
    Garg SK; Smith J; Beatson C; Lopez-Baca B; Voelmle M; Gottlieb PA
    Diabetes Technol Ther; 2009 Feb; 11(2):65-72. PubMed ID: 19243265
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Performance evaluation of a continuous glucose monitoring system under conditions similar to daily life.
    Pleus S; Schmid C; Link M; Zschornack E; Klötzer HM; Haug C; Freckmann G
    J Diabetes Sci Technol; 2013 Jul; 7(4):833-41. PubMed ID: 23911164
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Improved Accuracy of Continuous Glucose Monitoring Systems in Pediatric Patients with Diabetes Mellitus: Results from Two Studies.
    Laffel L
    Diabetes Technol Ther; 2016 Feb; 18 Suppl 2(Suppl 2):S223-33. PubMed ID: 26784126
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Accuracy of a 14-Day Factory-Calibrated Continuous Glucose Monitoring System With Advanced Algorithm in Pediatric and Adult Population With Diabetes.
    Alva S; Bailey T; Brazg R; Budiman ES; Castorino K; Christiansen MP; Forlenza G; Kipnes M; Liljenquist DR; Liu H
    J Diabetes Sci Technol; 2022 Jan; 16(1):70-77. PubMed ID: 32954812
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Performance evaluation of three continuous glucose monitoring systems: comparison of six sensors per subject in parallel.
    Freckmann G; Pleus S; Link M; Zschornack E; Klötzer HM; Haug C
    J Diabetes Sci Technol; 2013 Jul; 7(4):842-53. PubMed ID: 23911165
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparing the accuracy of transcutaneous sensor and 90-day implantable glucose sensor.
    Boscari F; Vettoretti M; Amato AML; Vallone V; Uliana A; Iori E; Avogaro A; Facchinetti A; Bruttomesso D
    Nutr Metab Cardiovasc Dis; 2021 Feb; 31(2):650-657. PubMed ID: 33594987
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A Prospective Multicenter Clinical Performance Evaluation of the C-CGM System.
    Rebec M; Cai K; Dutt-Ballerstadt R; Anderson E
    J Diabetes Sci Technol; 2022 Mar; 16(2):390-396. PubMed ID: 33084416
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.