BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

568 related articles for article (PubMed ID: 31850666)

  • 1. Comparison between two types of needles for Endoscopic Ultrasound (EUS)-guided fine aspiration biopsy of pancreatic and upper gastrointestinal masses.
    Alkhateeb K; Lee BB; Alatassi H; Sanders MA; Omer EM; McClave SA; Fraig M
    Diagn Cytopathol; 2020 Mar; 48(3):197-202. PubMed ID: 31850666
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Endoscopic ultrasound-guided sampling of solid pancreatic masses: 22-gauge aspiration versus 25-gauge biopsy needles.
    Yang MJ; Yim H; Hwang JC; Lee D; Kim YB; Lim SG; Kim SS; Kang JK; Yoo BM; Kim JH
    BMC Gastroenterol; 2015 Sep; 15():122. PubMed ID: 26419845
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A Comparative Study of the Diagnostic Utility of Endoscopic Ultrasound-Guided Fine Needle Aspiration Cytology (EUS-FNA) versus Endoscopic Ultrasound-Guided Fine Needle Biopsy (EUS-FNB) in Pancreatic and Non-Pancreatic Lesions.
    Yousri M; Abusinna E; Tahoun N; Okasha HH; El-Habashi AH
    Asian Pac J Cancer Prev; 2022 Jun; 23(6):2151-2158. PubMed ID: 35763660
    [TBL] [Abstract][Full Text] [Related]  

  • 4. In memoriam: Fine-needle aspiration, birth: Fine-needle biopsy: The changing trend in endoscopic ultrasound-guided tissue acquisition.
    Bang JY; Kirtane S; Krall K; Navaneethan U; Hasan M; Hawes R; Varadarajulu S
    Dig Endosc; 2019 Mar; 31(2):197-202. PubMed ID: 30256458
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Endoscopic Ultrasound-guided Sampling of Solid Pancreatic Lesions: A Comparative Analysis of 25 Gauge
    Siddique DA; Rahal MA; Trevino K; Wu HH; Al-Haddad MA
    Anticancer Res; 2020 Oct; 40(10):5845-5851. PubMed ID: 32988914
    [TBL] [Abstract][Full Text] [Related]  

  • 6. EUS-guided fine needle biopsy sampling using a novel fork-tip needle: a case-control study.
    Kandel P; Tranesh G; Nassar A; Bingham R; Raimondo M; Woodward TA; Gomez V; Wallace MB
    Gastrointest Endosc; 2016 Dec; 84(6):1034-1039. PubMed ID: 27018087
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Diagnostic performance of endoscopic ultrasound-guided tissue acquisition by EUS-FNA versus EUS-FNB for solid pancreatic mass without ROSE: a retrospective study.
    Wong T; Pattarapuntakul T; Netinatsunton N; Ovartlarnporn B; Sottisuporn J; Chamroonkul N; Sripongpun P; Jandee S; Kaewdech A; Attasaranya S; Piratvisuth T
    World J Surg Oncol; 2022 Jun; 20(1):215. PubMed ID: 35751053
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Endoscopic ultrasound with combined fine needle aspiration plus biopsy improves diagnostic yield in solid pancreatic masses.
    Gonzalez A; Wadhwa V; Singh H; Khan S; Gupta K; Liang H; Hussain I; Vargo J; Jang S; Chahal P; Bhatt A; Siddiki H; Erim T; Sanaka MR
    Scand J Gastroenterol; 2022 May; 57(5):610-617. PubMed ID: 34991430
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Endoscopic ultrasound-guided FNA and ProCore biopsy in sampling pancreatic and intra-abdominal masses.
    Dwyer J; Pantanowitz L; Ohori NP; Pai RK; Vrbin C; Brand RE; Monaco SE
    Cancer Cytopathol; 2016 Feb; 124(2):110-21. PubMed ID: 26430767
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Touch imprint cytology on endoscopic ultrasound fine-needle biopsy provides comparable sample quality and diagnostic yield to standard endoscopic ultrasound fine-needle aspiration specimens in the evaluation of solid pancreatic lesions.
    Crinò SF; Larghi A; Bernardoni L; Parisi A; Frulloni L; Gabbrielli A; Parcesepe P; Scarpa A; Manfrin E
    Cytopathology; 2019 Mar; 30(2):179-186. PubMed ID: 30484917
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A Meta-Analysis Comparing Endoscopic Ultrasound-guided Fine-needle Aspiration With Endoscopic Ultrasound-guided Fine-needle Biopsy.
    Li Z; Liu W; Xu X; Li P
    J Clin Gastroenterol; 2022 Sep; 56(8):668-678. PubMed ID: 35470294
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Endoscopic ultrasound-guided tissue acquisition of solid mass lesions of the pancreas: A retrospective comparison study of fine-needle aspiration and fine-needle biopsy.
    Sweeney J; Soong L; Goyal A
    Diagn Cytopathol; 2020 Apr; 48(4):322-329. PubMed ID: 31903736
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparing endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA) versus fine needle biopsy (FNB) in the diagnosis of solid lesions: study protocol for a randomized controlled trial.
    Wang J; Wu X; Yin P; Guo Q; Hou W; Li Y; Wang Y; Cheng B
    Trials; 2016 Apr; 17():198. PubMed ID: 27071386
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Core biopsy needle versus standard aspiration needle for endoscopic ultrasound-guided sampling of solid pancreatic masses: a randomized parallel-group study.
    Lee YN; Moon JH; Kim HK; Choi HJ; Choi MH; Kim DC; Lee TH; Cha SW; Cho YD; Park SH
    Endoscopy; 2014 Dec; 46(12):1056-62. PubMed ID: 25098611
    [TBL] [Abstract][Full Text] [Related]  

  • 15. EUS-guided 22-gauge fine-needle aspiration versus core biopsy needle in the evaluation of solid pancreatic neoplasms.
    Strand DS; Jeffus SK; Sauer BG; Wang AY; Stelow EB; Shami VM
    Diagn Cytopathol; 2014 Sep; 42(9):751-8. PubMed ID: 24550162
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Endoscopic Ultrasound-Guided Tissue Acquisition by 22-Gauge Franseen and Standard Needles for Solid Pancreatic Lesions.
    Ishigaki K; Nakai Y; Oyama H; Kanai S; Suzuki T; Nakamura T; Sato T; Hakuta R; Saito K; Saito T; Takahara N; Hamada T; Mizuno S; Kogure H; Tada M; Isayama H; Koike K
    Gut Liver; 2020 Nov; 14(6):817-825. PubMed ID: 32457276
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of endoscopic ultrasound-guided fine-needle biopsy versus fine-needle aspiration for genomic profiling and DNA yield in pancreatic cancer: a randomized crossover trial.
    Kandel P; Nassar A; Gomez V; Raimondo M; Woodward TA; Crook JE; Fares NS; Wallace MB
    Endoscopy; 2021 Apr; 53(4):376-382. PubMed ID: 32767288
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of 22G fine-needle aspiration (FNA) versus fine-needle biopsy (FNB) for endoscopic ultrasound-guided sampling of pancreatic lesions: a prospective comparison study.
    Tian L; Tang AL; Zhang L; Liu XW; Li JB; Wang F; Shen SR; Wang XY
    Surg Endosc; 2018 Aug; 32(8):3533-3539. PubMed ID: 29404729
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of 22-gauge standard fine needle versus core biopsy needle for endoscopic ultrasound-guided sampling of suspected pancreatic cancer: a randomized crossover trial.
    Noh DH; Choi K; Gu S; Cho J; Jang KT; Woo YS; Lee KT; Lee JK; Lee KH
    Scand J Gastroenterol; 2018 Jan; 53(1):94-99. PubMed ID: 29065734
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Does ProCore Fine-Needle Biopsy Really Improve the Clinical Outcome of Endoscopic Ultrasound-Guided Sampling of Pancreatic Masses?
    Delconte G; Cavalcoli F; Magarotto A; Centonze G; Bezzio C; Cattaneo L; Rausa E; Kelly ME; Bonitta G; Milione M; Enzo M
    Dig Dis; 2022; 40(1):78-84. PubMed ID: 33780932
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 29.