These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

142 related articles for article (PubMed ID: 31859648)

  • 1. [Biotin analytical interference on Siemens immunoanalysis on Dimension EXL®: impact on cardiac troponin I and total vitamin D (D
    Djebrani M; Jabbour F; Hulot FD; De Mazancourt P
    Ann Biol Clin (Paris); 2019 Dec; 77(6):693-696. PubMed ID: 31859648
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effect of Biotin on Cardiac Troponin I and High Sensitivity Cardiac Troponin I Assays on Vista 1500 and ADVIA Centaur Analyzer.
    Dasgupta A; Khalil S
    Ann Clin Lab Sci; 2021 Jan; 51(1):102-105. PubMed ID: 33653787
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Apparent Hyperthyroidism Caused by Biotin-Like Interference from IgM Anti-Streptavidin Antibodies.
    Lam L; Bagg W; Smith G; Chiu WW; Middleditch MJ; Lim JC; Kyle CV
    Thyroid; 2018 Aug; 28(8):1063-1067. PubMed ID: 29808739
    [TBL] [Abstract][Full Text] [Related]  

  • 4. False biochemical diagnosis of hyperthyroidism in streptavidin-biotin-based immunoassays: the problem of biotin intake and related interferences.
    Piketty ML; Polak M; Flechtner I; Gonzales-Briceño L; Souberbielle JC
    Clin Chem Lab Med; 2017 May; 55(6):780-788. PubMed ID: 27732554
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Intake of high dose biotin: A cause of artificial hyperthyroidism].
    Bouillet B; Rouland A
    Rev Med Interne; 2020 Feb; 41(2):123-125. PubMed ID: 31813616
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Independent and combined effects of biotin and hemolysis on high-sensitivity cardiac troponin assays.
    Harley K; Bissonnette S; Inzitari R; Schulz K; Apple FS; Kavsak PA; Gunsolus IL
    Clin Chem Lab Med; 2021 Jul; 59(8):1431-1443. PubMed ID: 33761581
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Discordant Analytical Results Caused by Biotin Interference on Diagnostic Immunoassays in a Pediatric Hospital.
    Ali M; Rajapakshe D; Cao L; Devaraj S
    Ann Clin Lab Sci; 2017 Sep; 47(5):638-640. PubMed ID: 29066495
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Association of Biotin Ingestion With Performance of Hormone and Nonhormone Assays in Healthy Adults.
    Li D; Radulescu A; Shrestha RT; Root M; Karger AB; Killeen AA; Hodges JS; Fan SL; Ferguson A; Garg U; Sokoll LJ; Burmeister LA
    JAMA; 2017 Sep; 318(12):1150-1160. PubMed ID: 28973622
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Biotin interference: evaluation of a new generation of electrochemiluminescent immunoassays for high-sensitive troponin T and thyroid-stimulating hormone testing.
    Mzougui S; Favresse J; Soleimani R; Fillée C; Gruson D
    Clin Chem Lab Med; 2020 Nov; 58(12):2037-2045. PubMed ID: 32324155
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Interference from anti-streptavidin antibody.
    Rulander NJ; Cardamone D; Senior M; Snyder PJ; Master SR
    Arch Pathol Lab Med; 2013 Aug; 137(8):1141-6. PubMed ID: 23899071
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Interference of anti-streptavidin antibodies: More common than we thought? In relation to six confirmed cases.
    Ricci V; Esteban MP; Sand G; Menises MM
    Clin Biochem; 2021 Apr; 90():62-65. PubMed ID: 33545112
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Free versus total serum 25-hydroxyvitamin D in a murine model of colitis.
    Larner DP; Jenkinson C; Chun RF; Westgate CSJ; Adams JS; Hewison M
    J Steroid Biochem Mol Biol; 2019 May; 189():204-209. PubMed ID: 30710745
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Characterization of biotin interference in 21 Vitros 5600 immunoassays and risk mitigation for patient safety at a large academic medical center.
    Stieglitz HM; Korpi-Steiner N
    Clin Biochem; 2020 Jan; 75():53-61. PubMed ID: 31677994
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Fortified malted milk drinks containing low-dose ergocalciferol and cholecalciferol do not differ in their capacity to raise serum 25-hydroxyvitamin D concentrations in healthy men and women not exposed to UV-B.
    Fisk CM; Theobald HE; Sanders TA
    J Nutr; 2012 Jul; 142(7):1286-90. PubMed ID: 22623396
    [TBL] [Abstract][Full Text] [Related]  

  • 15. High-dose biotin therapy leading to false biochemical endocrine profiles: validation of a simple method to overcome biotin interference.
    Piketty ML; Prie D; Sedel F; Bernard D; Hercend C; Chanson P; Souberbielle JC
    Clin Chem Lab Med; 2017 May; 55(6):817-825. PubMed ID: 28222020
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Serum concentration of vitamin D metabolites during treatment with vitamin D2 and D3 in normal premenopausal women.
    Tjellesen L; Hummer L; Christiansen C; Rødbro P
    Bone Miner; 1986 Oct; 1(5):407-13. PubMed ID: 2849489
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Immunoassay design and biotin interference.
    Dasgupta A
    Adv Clin Chem; 2022; 109():165-183. PubMed ID: 35953126
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Fake news? Biotin interference in thyroid immunoassays.
    Koehler VF; Mann U; Nassour A; Mann WA
    Clin Chim Acta; 2018 Sep; 484():320-322. PubMed ID: 29856977
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Biotin interference in immunoassays based on biotin-strept(avidin) chemistry: An emerging threat.
    Luong JHT; Male KB; Glennon JD
    Biotechnol Adv; 2019; 37(5):634-641. PubMed ID: 30872068
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Analytical characterization of the Siemens Dimension EXL high-sensitivity cardiac troponin I assay.
    Kavsak PA; MacCuish J; Boreyko J; Roy C; Lamers S; Clark L
    Clin Biochem; 2019 Jul; 69():52-56. PubMed ID: 31063741
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.