These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
300 related articles for article (PubMed ID: 31859660)
41. Evidence for Reduced Fatigue Resistance of Contemporary Rotary Instruments Exposed to Body Temperature. de Vasconcelos RA; Murphy S; Carvalho CA; Govindjee RG; Govindjee S; Peters OA J Endod; 2016 May; 42(5):782-7. PubMed ID: 26993574 [TBL] [Abstract][Full Text] [Related]
42. Cyclic fatigue of three types of rotary nickel-titanium files in a dynamic model. Yao JH; Schwartz SA; Beeson TJ J Endod; 2006 Jan; 32(1):55-7. PubMed ID: 16410070 [TBL] [Abstract][Full Text] [Related]
43. Cyclic Fatigue Resistance of Rotary and Reciprocating Nickel-Titanium Instruments Subjected to Static and Dynamic Tests. Thu M; Ebihara A; Maki K; Miki N; Okiji T J Endod; 2020 Nov; 46(11):1752-1757. PubMed ID: 32818563 [TBL] [Abstract][Full Text] [Related]
44. Variations in cyclic fatigue resistance among ProTaper Gold, ProTaper Next and ProTaper Universal instruments at different levels. Uygun AD; Kol E; Topcu MK; Seckin F; Ersoy I; Tanriver M Int Endod J; 2016 May; 49(5):494-9. PubMed ID: 26011308 [TBL] [Abstract][Full Text] [Related]
45. Effects of Autoclave Sterilization on Cyclic Fatigue Resistance in 5 Types of Rotary Endodontic Instruments: An In Vitro Study. Stošić N; Popović J; Anđelković Apostolović M; Mitić A; Nikolić M; Barac R; Kostić M Med Sci Monit; 2023 Mar; 29():e939694. PubMed ID: 36967567 [TBL] [Abstract][Full Text] [Related]
46. Cyclic fatigue of ProTaper rotary nickel-titanium instruments in artificial canals with 2 different radii of curvature. Inan U; Aydin C; Tunca YM Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2007 Dec; 104(6):837-40. PubMed ID: 17904394 [TBL] [Abstract][Full Text] [Related]
47. Investigation of four nickel titanium endodontic instruments, with cyclic fatigue resistance, scanning electron microscopy, and energy dispersive x-ray spectroscopy. Ertuğrul İF; Arslan HK Microsc Res Tech; 2024 Nov; 87(11):2801-2807. PubMed ID: 38988203 [TBL] [Abstract][Full Text] [Related]
48. Cyclic fatigue resistance of RaCe and Mtwo rotary files in continuous rotation and reciprocating motion. Vadhana S; SaravanaKarthikeyan B; Nandini S; Velmurugan N J Endod; 2014 Jul; 40(7):995-9. PubMed ID: 24935551 [TBL] [Abstract][Full Text] [Related]
49. Comparison between Single-file Rotary Systems: Part 2-The Effect of Length of the Instrument Subjected to Cyclic Loading on Cyclic Fatigue Resistance. Azim AA; Tarrosh M; Azim KA; Piasecki L J Endod; 2018 Dec; 44(12):1837-1842. PubMed ID: 30477669 [TBL] [Abstract][Full Text] [Related]
50. Effect of fatigue on torsional failure of nickel-titanium controlled memory instruments. Campbell L; Shen Y; Zhou HM; Haapasalo M J Endod; 2014 Apr; 40(4):562-5. PubMed ID: 24666912 [TBL] [Abstract][Full Text] [Related]
51. Cyclic fatigue resistance of nickel-titanium instruments after immersion in irrigant solutions with or without surfactants. Pedullà E; Franciosi G; Ounsi HF; Tricarico M; Rapisarda E; Grandini S J Endod; 2014 Aug; 40(8):1245-9. PubMed ID: 25069942 [TBL] [Abstract][Full Text] [Related]
52. Evaluation of the Cyclic Fatigue and Torsional Resistance of Novel Nickel-Titanium Rotary Files with Various Alloy Properties. Kaval ME; Capar ID; Ertas H J Endod; 2016 Dec; 42(12):1840-1843. PubMed ID: 27776878 [TBL] [Abstract][Full Text] [Related]
53. Influence of environmental temperature, heat-treatment and design on the cyclic fatigue resistance of three generations of a single-file nickel-titanium rotary instrument. Staffoli S; Grande NM; Plotino G; Özyürek T; Gündoğar M; Fortunato L; Polimeni A Odontology; 2019 Jul; 107(3):301-307. PubMed ID: 30483996 [TBL] [Abstract][Full Text] [Related]
54. Resistance to cyclic fatigue failure of a new endodontic rotary file. Bouska J; Justman B; Williamson A; DeLong C; Qian F J Endod; 2012 May; 38(5):667-9. PubMed ID: 22515898 [TBL] [Abstract][Full Text] [Related]
55. Comparison of the cyclic fatigue resistance of hyflex EDM, vortex blue, protaper gold, and onecurve nickel-Titanium instruments. Uygun AD; Unal M; Falakaloglu S; Guven Y Niger J Clin Pract; 2020 Jan; 23(1):41-45. PubMed ID: 31929205 [TBL] [Abstract][Full Text] [Related]
56. Effects of raw material and rotational speed on the cyclic fatigue of ProFile Vortex rotary instruments. Gao Y; Shotton V; Wilkinson K; Phillips G; Johnson WB J Endod; 2010 Jul; 36(7):1205-9. PubMed ID: 20630300 [TBL] [Abstract][Full Text] [Related]
57. Influence of Temperature on Cyclic Fatigue Resistance of ProTaper Gold and ProTaper Universal Rotary Files. Plotino G; Grande NM; Mercadé Bellido M; Testarelli L; Gambarini G J Endod; 2017 Feb; 43(2):200-202. PubMed ID: 27989581 [TBL] [Abstract][Full Text] [Related]
58. Cyclic fatigue analysis of a new generation of nickel titanium rotary instruments. Larsen CM; Watanabe I; Glickman GN; He J J Endod; 2009 Mar; 35(3):401-3. PubMed ID: 19249604 [TBL] [Abstract][Full Text] [Related]
59. Dynamic cyclic and torsional fatigue resistance of TruNatomy compared with different nickel-titanium rotary instruments. Elnaghy AM; Elsaka SE; Elshazli AH Aust Endod J; 2020 Aug; 46(2):226-233. PubMed ID: 32022376 [TBL] [Abstract][Full Text] [Related]
60. An in vitro comparison of torsional stress properties of three different rotary nickel-titanium files with a similar cross-sectional design. Wycoff RC; Berzins DW J Endod; 2012 Aug; 38(8):1118-20. PubMed ID: 22794218 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]