These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

241 related articles for article (PubMed ID: 31864145)

  • 1. Radiation dose in cone beam CT guided ERCP.
    Waldthaler A; Reuterwall-Hansson M; Arnelo U; Kadesjö N
    Eur J Radiol; 2020 Feb; 123():108789. PubMed ID: 31864145
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Radiation exposure during TACE procedures using additional cone-beam CT (CBCT) for guidance: safety and precautions.
    Jonczyk M; Collettini F; Geisel D; Schnapauff D; Böning G; Wieners G; Gebauer G
    Acta Radiol; 2018 Nov; 59(11):1277-1284. PubMed ID: 29490465
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Pediatric Percutaneous Osteoid Osteoma Ablation: Cone-Beam CT with Fluoroscopic Overlay Versus Conventional CT Guidance.
    Perry BC; Monroe EJ; McKay T; Kanal KM; Shivaram G
    Cardiovasc Intervent Radiol; 2017 Oct; 40(10):1593-1599. PubMed ID: 28497188
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of cone-beam CT-guided and CT fluoroscopy-guided transthoracic needle biopsy of lung nodules.
    Rotolo N; Floridi C; Imperatori A; Fontana F; Ierardi AM; Mangini M; Arlant V; De Marchi G; Novario R; Dominioni L; Fugazzola C; Carrafiello G
    Eur Radiol; 2016 Feb; 26(2):381-9. PubMed ID: 26045345
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Cone beam computed tomography (CBCT) guidance is helpful in reducing dose exposure to pediatric patients undergoing radiofrequency ablation of osteoid osteoma.
    Fiore F; Somma F; D'Angelo R; Tarotto L; Stoia V
    Radiol Med; 2022 Feb; 127(2):183-190. PubMed ID: 34958441
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Dosimetric Feasibility of Cone-Beam CT in Pediatric Image-Guided Retrograde Gastrostomy Tube Insertions.
    Shkumat NA; Brashdi YA; Volodina S; Parra D; Connolly BL
    Can Assoc Radiol J; 2020 Feb; 71(1):68-74. PubMed ID: 32062990
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Diagnostic Reference Levels for Fluoroscopy-guided Gastrointestinal Procedures in Japan from the REX-GI Study: A Nationwide Multicentre Prospective Observational Study.
    Hayashi S; Takenaka M; Hosono M; Kogure H; Hasatani K; Suda T; Maruyama H; Matsunaga K; Ihara H; Yoshio T; Nagaike K; Yamada T; Yakushijin T; Takagi T; Tsumura H; Kurita A; Asai S; Ito Y; Kuwai T; Hori Y; Maetani I; Ikezawa K; Iwashita T; Matsumoto K; Fujisawa T; Nishida T
    Lancet Reg Health West Pac; 2022 Mar; 20():100376. PubMed ID: 35036979
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Analysis of Patients' X-ray Exposure in 146 Percutaneous Radiologic Gastrostomies.
    Petersen TO; Reinhardt M; Fuchs J; Gosch D; Surov A; Stumpp P; Kahn T; Moche M
    Rofo; 2017 Sep; 189(9):820-827. PubMed ID: 28609790
    [No Abstract]   [Full Text] [Related]  

  • 9. Clinical Experience with Real-Time 3-D Guidance Based on C-Arm-Acquired Cone-Beam CT (CBCT) in Transjugular Intrahepatic Portosystemic Stent Shunt (TIPSS) Placement.
    Böning G; Lüdemann WM; Chapiro J; Jonczyk M; Hamm B; Günther RW; Gebauer B; Streitparth F
    Cardiovasc Intervent Radiol; 2018 Jul; 41(7):1035-1042. PubMed ID: 29541837
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Multicentre prospective observational study protocol for radiation exposure from gastrointestinal fluoroscopic procedures (REX-GI study).
    Nishida T; Hayashi S; Takenaka M; Hosono M; Kogure H; Hasatani K; Yamaguchi S; Maruyama H; Doyama H; Ihara H; Yoshio T; Nagaike K; Yamada T; Yakushijin T; Takagi T; Tsumura H; Kurita A; Asai S; Ito Y; Kuwai T; Hori Y; Maetani I; Ikezawa K; Iwashita T; Matsumoto K; Inada M;
    BMJ Open; 2020 Feb; 10(2):e033604. PubMed ID: 32107268
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Minimizing Radiation Exposure During ERCP by Avoiding Live or Continuous Fluoroscopy.
    Churrango G; Deutsch JK; Dinneen HS; Churrango J; Samiullah S; Ahlawat SK
    J Clin Gastroenterol; 2015; 49(10):e96-100. PubMed ID: 26191644
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Dual-phase Cone-beam CT-based Navigation Imaging Significantly Enhances Tumor Detectability and Aids Superselective Transarterial Chemoembolization of Liver Cancer.
    Yao X; Yan D; Jiang X; Li X; Zeng H; Liu D; Li H
    Acad Radiol; 2018 Aug; 25(8):1031-1037. PubMed ID: 29398432
    [TBL] [Abstract][Full Text] [Related]  

  • 13. THE IMPACT OF X-RAY UNIT TYPE USED FOR ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY PROCEDURES ON PATIENT DOSES.
    Tsapaki V; Paraskeva KD; Tsalafoutas IA; Paspatis G; Scotiniotis H; Georgopoulos P; Finou P; Karagianis JA
    Radiat Prot Dosimetry; 2016 Dec; 171(4):503-508. PubMed ID: 26582174
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Patient radiation dose and fluoroscopy time during ERCP: a single-center, retrospective study of influencing factors.
    Saukko E; Grönroos JM; Salminen P; Henner A; Nieminen MT
    Scand J Gastroenterol; 2018 Apr; 53(4):495-504. PubMed ID: 29489436
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of Radiation Exposure and Influential Factors in Cone-Beam Computed Tomography (CBCT) of the Head and Abdomen during Interventional Procedures.
    Li M; Qu W; Zhang D; Zhong B; Li Z; Jiang Z; Ni G; Ni C
    Tomography; 2024 Feb; 10(3):320-330. PubMed ID: 38535767
    [TBL] [Abstract][Full Text] [Related]  

  • 16. C-Arm Cone Beam CT for Intraprocedural Image Fusion and 3D Guidance in Portal Vein Embolization (PVE).
    Lüdemann WM; Böning G; Chapiro J; Jonczyk M; Geisel D; Schnapauff D; Wieners G; Schmelzle M; Chopra S; Günther RW; Gebauer B; Streitparth F
    Cardiovasc Intervent Radiol; 2018 Mar; 41(3):424-432. PubMed ID: 28875339
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Prospective nonrandomized study to evaluate cone beam computed tomography for technical assessment of standard and complex endovascular aortic repair.
    Tenorio ER; Oderich GS; Sandri GA; Ozbek P; Kärkkäinen JM; Vrtiska T; Macedo TA; Gloviczki P
    J Vasc Surg; 2020 Jun; 71(6):1982-1993.e5. PubMed ID: 31611108
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effects of a Brief Educational Program on Optimization of Fluoroscopy to Minimize Radiation Exposure During Endoscopic Retrograde Cholangiopancreatography.
    Barakat MT; Thosani NC; Huang RJ; Choudhary A; Kochar R; Kothari S; Banerjee S
    Clin Gastroenterol Hepatol; 2018 Apr; 16(4):550-557. PubMed ID: 28804031
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Radiation exposure of abdominal cone beam computed tomography.
    Sailer AM; Schurink GW; Wildberger JE; de Graaf R; van Zwam WH; de Haan MW; Kemerink GJ; Jeukens CR
    Cardiovasc Intervent Radiol; 2015 Feb; 38(1):112-20. PubMed ID: 24798137
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Prostatic Artery Embolization: Influence of Cone-Beam Computed Tomography on Radiation Exposure, Procedure Time, and Contrast Media Use.
    Bürckenmeyer F; Diamantis I; Kriechenbauer T; Lehmann T; Franiel T; Malouhi A; Grimm MO; Teichgräber U; Aschenbach R
    Cardiovasc Intervent Radiol; 2021 Jul; 44(7):1089-1094. PubMed ID: 33660064
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.