These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

137 related articles for article (PubMed ID: 31864194)

  • 1. Clinical and radiographic features of hydrolyzed MIRAgel scleral buckles: A comparative analysis.
    Reshef ER; Habib LA; Rao R; Modjtahedi BS; Eliott D; Freitag SK; Reinshagen KL; Lee NG
    Clin Imaging; 2020 Mar; 60(1):10-15. PubMed ID: 31864194
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Long-term complications of MIRAgel exoplants in scleral buckling surgery].
    Hida T; Oshitari K
    Nippon Ganka Gakkai Zasshi; 2003 Feb; 107(2):71-5. PubMed ID: 12647330
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Complications Assoicated with MIRAgel for Treatment of Retinal Detachment.
    Roh M; Lee NG; Miller JB
    Semin Ophthalmol; 2018; 33(1):89-94. PubMed ID: 29144829
    [TBL] [Abstract][Full Text] [Related]  

  • 4. MIRAgel Buckle Extrusion With Preseptal Cellulitis and Erosion Through the Eyelid Skin.
    Orban MW; Haddock LJ
    Ophthalmic Surg Lasers Imaging Retina; 2016 Dec; 47(12):1147-1150. PubMed ID: 27977839
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Expanding MIRAgel scleral buckle simulating an orbital tumor in four cases.
    Shields CL; Demirci H; Marr BP; Mashayekhi A; Materin MA; Shields JA
    Ophthalmic Plast Reconstr Surg; 2005 Jan; 21(1):32-8. PubMed ID: 15677950
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Late swelling and removal of Miragel buckles: a comparison with silicone indentations.
    Le Rouic JF; Bettembourg O; D'Hermies F; Azan F; Renard G; Chauvaud D
    Retina; 2003 Oct; 23(5):641-6. PubMed ID: 14574248
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Episcleral Miragel buckling elements removal. A clinical case-series].
    Le Rouic JF; Bettembourg O; D'Hermies F; Azan F; Tran C; Renard G; Chauvaud D
    J Fr Ophtalmol; 2002 Dec; 25(10):1002-6. PubMed ID: 12527822
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Late complications of hydrogel scleral buckle implants and a technique for effective removal.
    Richards AL; Meyer DR
    Ophthalmic Plast Reconstr Surg; 2012; 28(6):455-8. PubMed ID: 23034689
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Globe Loss From Intraocular Invasion of MIRAgel Scleral Buckle Components.
    Rubinstein TJ; Choudhary MM; Modi YS; Ehlers JP; Perry JD
    Ophthalmic Plast Reconstr Surg; 2016; 32(5):329-32. PubMed ID: 26226237
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Scleral MIRAgel causing bony orbital erosion.
    Figueira EC; Francis IC; Wilcsek GA
    Orbit; 2007 Mar; 26(1):65-9. PubMed ID: 17510877
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Scleral Erosion Secondary to MIRAgel Scleral Buckle.
    Clauss KD; Patel N; Dubovy SR; Rong AJ
    Ophthalmic Plast Reconstr Surg; 2021 Jul-Aug 01; 37(4):e152. PubMed ID: 33079760
    [No Abstract]   [Full Text] [Related]  

  • 12. Intrusion, Extrusion, and Infection of a Hydrolyzed MIRAgel Scleral Buckle.
    Feng Y; Chiou CA; Lee NG
    Am J Ophthalmol; 2023 Mar; 247():e1-e2. PubMed ID: 36493849
    [No Abstract]   [Full Text] [Related]  

  • 13. MIRAgel: hydrolytic degradation and long-term observations.
    Roldán-Pallarés M; Hernández-Montero J; Llanes F; Fernández-Rubio JE; Ortega F
    Arch Ophthalmol; 2007 Apr; 125(4):511-4. PubMed ID: 17420371
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Histopathology of Hydrolyzed MIRAgel Scleral Buckles.
    Wolkow N; Jakobiec FA
    Ocul Oncol Pathol; 2021 Sep; 7(4):272-279. PubMed ID: 34604200
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Orbital complications of hydrogel scleral buckles.
    Bernardino CR; Mihora LD; Fay AM; Rubin PA
    Ophthalmic Plast Reconstr Surg; 2006; 22(3):206-8. PubMed ID: 16714931
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Miragel in surgery of retinal detachment].
    Kmera-Muszyńska M; Kecik T; Okuniewska-Kalicka M
    Klin Oczna; 1993; 95(9-10):363-5. PubMed ID: 8022171
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Late Complications After Retinal Surgery Using Hydrogel (MIRAgel®) Sponges].
    Kandzia C; Roider J
    Klin Monbl Augenheilkd; 2019 May; 236(5):699-703. PubMed ID: 28810282
    [No Abstract]   [Full Text] [Related]  

  • 18. Removal of MIRAgel Scleral Buckle Implants: The Direct Aspiration Technique.
    Santorum P; De Vitto AML; Bertelli E
    Retina; 2022 Oct; 42(10):2013-2017. PubMed ID: 31299037
    [No Abstract]   [Full Text] [Related]  

  • 19. Hydrogel (Miragel®) scleral explant, late orbital complication.
    ALBalawi HB; Asharari KS; Alali NM; ALRaddadi O; Magliyah M; Alanazi GB
    Int J Surg Case Rep; 2022 Sep; 98():107583. PubMed ID: 36063767
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Diplopia and periorbital mass associated with Miragel buckling explant.
    Chung EJ; Oh HS; Lee SC; Kwon OW
    Korean J Ophthalmol; 2004 Jun; 18(1):47-51. PubMed ID: 15255237
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.