These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
121 related articles for article (PubMed ID: 31875378)
1. [Study on mechanical properties of nitinol iliac vein stent and animal test under different release scales]. Feng H; Wang S; Wang Y; Li X; Wang X Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2019 Dec; 36(6):1024-1031. PubMed ID: 31875378 [TBL] [Abstract][Full Text] [Related]
2. In vivo evaluation of safety and performance of a nitinol venous stent in an ovine iliac venous model. Marston WA; Chinubhai A; Kao S; Kalbaugh C; Kouri A J Vasc Surg Venous Lymphat Disord; 2016 Jan; 4(1):73-9. PubMed ID: 26946899 [TBL] [Abstract][Full Text] [Related]
3. Finite element analysis of the biomechanical interaction between coronary sinus and proximal anchoring stent in coronary sinus annuloplasty. Pham T; Deherrera M; Sun W Comput Methods Biomech Biomed Engin; 2014; 17(14):1617-29. PubMed ID: 23405942 [TBL] [Abstract][Full Text] [Related]
4. Delivery and release of nitinol stent in carotid artery and their interactions: a finite element analysis. Wu W; Qi M; Liu XP; Yang DZ; Wang WQ J Biomech; 2007; 40(13):3034-40. PubMed ID: 17511995 [TBL] [Abstract][Full Text] [Related]
5. [Comparative study on the mechanical properties of lower limb arterial stents under various deformation modes]. Wang T; Feng H; Wang K Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2021 Apr; 38(2):303-309. PubMed ID: 33913290 [TBL] [Abstract][Full Text] [Related]
6. Finite element analysis for fatigue behaviour of a self-expanding Nitinol peripheral stent under physiological biomechanical conditions. Lei L; Qi X; Li S; Yang Y; Hu Y; Li B; Zhao S; Zhang Y Comput Biol Med; 2019 Jan; 104():205-214. PubMed ID: 30529572 [TBL] [Abstract][Full Text] [Related]
7. [Finite Element Analysis of Effect of Key Dimension of Nitinol Stent on Its Fatigue Behaviour]. Li J; Wang S Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2015 Apr; 32(2):305-10. PubMed ID: 26211245 [TBL] [Abstract][Full Text] [Related]
8. [Optimization based on finite element technique of nitinol stent]. Lin F; Liu X; Huang N; Gao Q; Li Z; Yao T; Luo Q; Huang J Zhongguo Yi Liao Qi Xie Za Zhi; 2014 Mar; 38(2):98-101. PubMed ID: 24941770 [TBL] [Abstract][Full Text] [Related]
9. Nitinol Stent Oversizing in Patients Undergoing Popliteal Artery Revascularization: A Finite Element Study. Gökgöl C; Diehm N; Nezami FR; Büchler P Ann Biomed Eng; 2015 Dec; 43(12):2868-80. PubMed ID: 26101031 [TBL] [Abstract][Full Text] [Related]
10. [Safety performance of self-expandable NiTi alloy stent]. Li Z; Yan W; Feng H Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2020 Apr; 37(2):334-339. PubMed ID: 32329287 [TBL] [Abstract][Full Text] [Related]
11. Short- and long-term histopathologic evaluation of stenting using a self-expanding nitinol stent in pig carotid and iliac arteries. Verheye S; Salame MY; Robinson KA; Post MJ; Carrozza JP; Baim DS; Sigwart U; King SB; Chronos NA Catheter Cardiovasc Interv; 1999 Nov; 48(3):316-23. PubMed ID: 10525238 [TBL] [Abstract][Full Text] [Related]
12. Percutaneous deployment of a valved bovine jugular vein in the swine venous system: a potential treatment for venous insufficiency. Gomez-Jorge J; Venbrux AC; Magee C J Vasc Interv Radiol; 2000; 11(7):931-6. PubMed ID: 10928534 [TBL] [Abstract][Full Text] [Related]
13. Early clinical outcomes for treatment of post-thrombotic syndrome and common iliac vein compression with a hybrid Oblique self-expanding nitinol stent - the TOPOS study. Sebastian T; Lichtenberg M; Schlager O; Jalaie H; de Graaf R; Erbel C; Massmann A; Schindewolf M; Grigorean A; Kucher N Vasa; 2020 Jun; 49(4):301-308. PubMed ID: 32248759 [No Abstract] [Full Text] [Related]
14. Analysis of Fatigue Strength and Reliability of Lower Limb Arterial Stent at Different Vascular Stenosis Rates and Stent-to-Artery Ratios. Ma S; Feng H; Feng H; Su J Ann Biomed Eng; 2023 Jun; 51(6):1136-1146. PubMed ID: 36939956 [TBL] [Abstract][Full Text] [Related]
15. A practice audit of short-term outcomes of Wallstents versus Venovo stents for the treatment of nonthrombotic iliac vein outflow stenoses. Sulakvelidze L; Lakhanpal G; Lakhanpal S; Kennedy R; Lakhanpal R; Pappas PJ J Vasc Surg Venous Lymphat Disord; 2023 Mar; 11(2):357-364. PubMed ID: 36182087 [TBL] [Abstract][Full Text] [Related]
16. Patency and Clinical Outcomes of a Dedicated, Self-Expanding, Hybrid Oblique Stent Used in the Treatment of Common Iliac Vein Compression. Stuck AK; Kunz S; Baumgartner I; Kucher N J Endovasc Ther; 2017 Feb; 24(1):159-166. PubMed ID: 27831483 [TBL] [Abstract][Full Text] [Related]
17. The influencing mechanism of iliac vein stent implantation for hemodynamics at the bifurcation. Li C; Feng H; Wang X; Wang Y Comput Methods Biomech Biomed Engin; 2023 Sep; 26(12):1452-1461. PubMed ID: 36082958 [TBL] [Abstract][Full Text] [Related]
18. Comparison of a microporous thermoplastic polyurethane-covered stent with a self-expanding bare nitinol stent in a porcine iliac artery model. Radeleff B; Grenacher L; Christoph P; Sommer CM; Stampfl U; Ramsauer S; Henn T; Kurz P; Lopez-Benitez R; Berger I; Richter GM J Vasc Interv Radiol; 2009 Jul; 20(7):927-35. PubMed ID: 19497761 [TBL] [Abstract][Full Text] [Related]
19. Multi-objective optimization of nitinol stent design. Alaimo G; Auricchio F; Conti M; Zingales M Med Eng Phys; 2017 Sep; 47():13-24. PubMed ID: 28705512 [TBL] [Abstract][Full Text] [Related]
20. Finite element analyses for improved design of peripheral stents. Lim YH; Jeong HY Comput Methods Biomech Biomed Engin; 2017 May; 20(6):653-662. PubMed ID: 28349767 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]