These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

154 related articles for article (PubMed ID: 31876004)

  • 21. In vitro comparison of the retentive properties of ball and locator attachments for implant overdentures.
    Türk PE; Geckili O; Türk Y; Günay V; Bilgin T
    Int J Oral Maxillofac Implants; 2014; 29(5):1106-13. PubMed ID: 25216136
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Retentive force variations of stud attachments for implant overdentures.
    Boulos PJ; Akiki LA; Makzoumé JE; Fakhoury J; Tohmé H; El Hage FS
    Gen Dent; 2018; 66(4):41-45. PubMed ID: 29964247
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Effect of Different Degrees of Mesial Implant Inclination on the Retention and Stability of Two-Implant Mandibular Overdentures Retained with Stud Attachments: An In Vitro Study.
    ELsyad MA; Abo Hatem OE; Shawky AF; Emera RMK
    Int J Oral Maxillofac Implants; 2018; 33(2):259–268. PubMed ID: 29028850
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Effect of Labial Implant Inclination on the Retention and Stability of Different Resilient Stud Attachments for Mandibular Implant Overdentures: An In vitro Study.
    ELsyad MA; Emera RM; Ibrahim AM
    Int J Oral Maxillofac Implants; 2019; 34(2):381–389. PubMed ID: 30703183
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Effect of implant angulation on attachment retention in mandibular two-implant overdentures: a clinical study.
    Jabbour Z; Fromentin O; Lassauzay C; Abi Nader S; Correa JA; Feine J; de Albuquerque Junior RF
    Clin Implant Dent Relat Res; 2014 Aug; 16(4):565-71. PubMed ID: 23305358
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Effect of dislodging forces on mandibular implant attachment-retained overdenture.
    Elkerdawy MW; Radi IA
    Implant Dent; 2011 Jun; 20(3):246-54. PubMed ID: 21613951
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Retentive characteristics of individual and prefabricated polyvinylsiloxane overdenture attachments: alternative treatment options for geriatric patients.
    Schweyen R; Arnold C; Setz JM; Hey J
    Clin Oral Investig; 2019 Mar; 23(3):1425-1434. PubMed ID: 30032470
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Retentive Properties of O-Ring and Locator Attachments for Implant-Retained Maxillary Overdentures: An In Vitro Study.
    ELsyad MA; Elhaddad AA; Khirallah AS
    J Prosthodont; 2018 Jul; 27(6):568-576. PubMed ID: 27589487
    [TBL] [Abstract][Full Text] [Related]  

  • 29. An in vitro study of non-axial forces upon the retention of an O-ring attachment.
    Rodrigues RC; Faria AC; Macedo AP; Sartori IA; de Mattos Mda G; Ribeiro RF
    Clin Oral Implants Res; 2009 Dec; 20(12):1314-9. PubMed ID: 19681968
    [TBL] [Abstract][Full Text] [Related]  

  • 30. The Influence of Implant Inclination on Retention and Peri-implant Stresses of Stud-Retained Implant Overdentures During Axial and Nonaxial Dislodgments: An In Vitro Study.
    Alameldeen HE; Elsyad MA; Shawky AF; Khirallah AS
    Int J Oral Maxillofac Implants; 2020; 35(3):543-550. PubMed ID: 32406652
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Comparison of retention and stability of implant-retained overdentures based upon implant number and distribution.
    Scherer MD; McGlumphy EA; Seghi RR; Campagni WV
    Int J Oral Maxillofac Implants; 2013; 28(6):1619-28. PubMed ID: 24278931
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Effect of implant angulation upon retention of overdenture attachments.
    Gulizio MP; Agar JR; Kelly JR; Taylor TD
    J Prosthodont; 2005 Mar; 14(1):3-11. PubMed ID: 15733129
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Retention and wear of resin matrix attachments for implant overdentures.
    Wichmann N; Kern M; Taylor T; Wille S; Passia N
    J Mech Behav Biomed Mater; 2020 Oct; 110():103901. PubMed ID: 32957206
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Retention of implant-supported overdentures at different implant angulations: comparing Locator and ball attachments.
    Sultana N; Bartlett DW; Suleiman M
    Clin Oral Implants Res; 2017 Nov; 28(11):1406-1410. PubMed ID: 28191678
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Comparison of retention and stability of two implant-retained overdentures based on implant location.
    Scherer MD; McGlumphy EA; Seghi RR; Campagni WV
    J Prosthet Dent; 2014 Sep; 112(3):515-21. PubMed ID: 24819528
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Effects of Low-Profile Stud Attachment Configurations on Stress Distribution Characteristics of Implant-Retained Overdentures.
    Tokar E; Uludag B
    Int J Oral Maxillofac Implants; 2018; 33(4):754-763. PubMed ID: 30024990
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Effects of interimplant distance and cyclic dislodgement on retention of LOCATOR and ball attachments: An in vitro study.
    Salehi R; Shayegh SS; Johnston WM; Hakimaneh SMR
    J Prosthet Dent; 2019 Dec; 122(6):550-556. PubMed ID: 31027962
    [TBL] [Abstract][Full Text] [Related]  

  • 38. The influence of interimplant distance and attachment type on the retention characteristics of mandibular overdentures on 2 implants: initial retention values.
    Michelinakis G; Barclay CW; Smith PW
    Int J Prosthodont; 2006; 19(5):507-12. PubMed ID: 17323731
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Retention of prefabricated attachments for implant stabilized overdentures in the edentulous mandible: an in vitro study.
    Setz I; Lee SH; Engel E
    J Prosthet Dent; 1998 Sep; 80(3):323-9. PubMed ID: 9760365
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Retention and Stability of Implant-Retained Mandibular Overdentures Using Different Types of Resilient Attachments: An In Vitro Study.
    ELsyad MA; Agha NN; Habib AA
    Int J Oral Maxillofac Implants; 2016; 31(5):1040-8. PubMed ID: 27632258
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.