These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

357 related articles for article (PubMed ID: 31877989)

  • 1. Loop-Mediated Isothermal Amplification (LAMP) for the Diagnosis of Zika Virus: A Review.
    Silva SJRD; Pardee K; Pena L
    Viruses; 2019 Dec; 12(1):. PubMed ID: 31877989
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Development and validation of a one-step reverse transcription loop-mediated isothermal amplification (RT-LAMP) for rapid detection of ZIKV in patient samples from Brazil.
    da Silva SJR; Pardee K; Balasuriya UBR; Pena L
    Sci Rep; 2021 Feb; 11(1):4111. PubMed ID: 33602985
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Development and Validation of Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) for Rapid Detection of ZIKV in Mosquito Samples from Brazil.
    Silva SJRD; Paiva MHS; Guedes DRD; Krokovsky L; Melo FL; Silva MALD; Silva AD; Ayres CFJ; Pena LJ
    Sci Rep; 2019 Mar; 9(1):4494. PubMed ID: 30872672
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A reverse transcription loop-mediated isothermal amplification for broad coverage detection of Asian and African Zika virus lineages.
    Teoh BT; Chin KL; Samsudin NI; Loong SK; Sam SS; Tan KK; Khor CS; Abd-Jamil J; Zainal N; Wilder-Smith A; Zandi K; AbuBakar S
    BMC Infect Dis; 2020 Dec; 20(1):947. PubMed ID: 33308203
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Development of Universal and Lineage-Specific Primer Sets for Rapid Detection of the Zika Virus (ZIKV) in Blood and Urine Samples Using One-Step Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP).
    Bui TT; Moi ML; Morita K; Hasebe F
    Jpn J Infect Dis; 2020 Mar; 73(2):153-156. PubMed ID: 31666491
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Development and Validation of Real-Time RT-LAMP Assays for the Specific Detection of Zika Virus.
    Lopez-Jimena B; Bakheit M; Bekaert M; Harold G; Frischmann S; Fall C; Diagne CT; Faye O; Faye O; Sall AA; Weidmann M
    Methods Mol Biol; 2020; 2142():147-164. PubMed ID: 32367366
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Detection of Zika Virus Using Reverse Transcription-Loop-Mediated Isothermal Amplification (RT-LAMP).
    Lamb LE; Bartolone SN; Chancellor MB
    Methods Mol Biol; 2020; 2142():137-146. PubMed ID: 32367365
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Development and evaluation of a visible reverse transcription-loop-mediated isothermal amplification (RT-LAMP) for the detection of Asian lineage ZIKV in field-caught mosquitoes.
    Siriyasatien P; Wacharapluesadee S; Kraivichian K; Suwanbamrung C; Sutthanont N; Cantos-Barreda A; Phumee A
    Acta Trop; 2022 Dec; 236():106691. PubMed ID: 36103950
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of a field-deployable reverse transcription-insulated isothermal PCR for rapid and sensitive on-site detection of Zika virus.
    Carossino M; Li Y; Lee PA; Tsai CF; Chou PH; Williams D; Skillman A; Frank Cook R; Brown G; Chang HG; Wang HT; Balasuriya UBR
    BMC Infect Dis; 2017 Dec; 17(1):778. PubMed ID: 29258444
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Lab-on-a-Chip Zika Detection With Reverse Transcription Loop-Mediated Isothermal Amplification-Based Assay for Point-of-Care Settings.
    Sharma S; Kabir MA; Asghar W
    Arch Pathol Lab Med; 2020 Nov; 144(11):1335-1343. PubMed ID: 32886758
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Sensitive and rapid detection of Zika virus by loop-mediated isothermal amplification.
    Zhao J; Feng R
    Virus Genes; 2019 Feb; 55(1):43-50. PubMed ID: 30426316
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparative Analysis of Zika Virus Detection by RT-qPCR, RT-LAMP, and RT-RPA.
    Diagne CT; Faye M; Lopez-Jimena B; Abd El Wahed A; Loucoubar C; Fall C; Mencatelli G; Faye O; Faye O; Weidmann M; Sall AA
    Methods Mol Biol; 2020; 2142():165-179. PubMed ID: 32367367
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Ten-minute direct detection of Zika virus in serum samples by RT-LAMP.
    Estrela PFN; Mendes GM; de Oliveira KG; Bailão AM; Soares CMA; Assunção NA; Duarte GRM
    J Virol Methods; 2019 Sep; 271():113675. PubMed ID: 31170469
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Reverse Transcription-Loop-mediated Isothermal Amplification (RT-LAMP) Assay for Zika Virus and Housekeeping Genes in Urine, Serum, and Mosquito Samples.
    Bartolone SN; Tree MO; Conway MJ; Chancellor MB; Lamb LE
    J Vis Exp; 2018 Sep; (139):. PubMed ID: 30272674
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Simpler, Faster, and Sensitive Zika Virus Assay Using Smartphone Detection of Loop-mediated Isothermal Amplification on Paper Microfluidic Chips.
    Kaarj K; Akarapipad P; Yoon JY
    Sci Rep; 2018 Aug; 8(1):12438. PubMed ID: 30127503
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Simple and Highly Sensitive Molecular Diagnosis of Zika Virus by Lateral Flow Assays.
    Lee D; Shin Y; Chung S; Hwang KS; Yoon DS; Lee JH
    Anal Chem; 2016 Dec; 88(24):12272-12278. PubMed ID: 28193014
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Instrument-Free Point-of-Care Molecular Detection of Zika Virus.
    Song J; Mauk MG; Hackett BA; Cherry S; Bau HH; Liu C
    Anal Chem; 2016 Jul; 88(14):7289-94. PubMed ID: 27306491
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Rapid colorimetric detection of Zika virus from serum and urine specimens by reverse transcription loop-mediated isothermal amplification (RT-LAMP).
    Calvert AE; Biggerstaff BJ; Tanner NA; Lauterbach M; Lanciotti RS
    PLoS One; 2017; 12(9):e0185340. PubMed ID: 28945787
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Point of sampling detection of Zika virus within a multiplexed kit capable of detecting dengue and chikungunya.
    Yaren O; Alto BW; Gangodkar PV; Ranade SR; Patil KN; Bradley KM; Yang Z; Phadke N; Benner SA
    BMC Infect Dis; 2017 Apr; 17(1):293. PubMed ID: 28427352
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Development and validation of loop-mediated isothermal amplification for the detection of the Zika virus].
    Escalante-Maldonado O; Gavilán RG; García MP; Marcelo A; Pacheco E; Cabezas C; Yamazaki W
    Rev Peru Med Exp Salud Publica; 2019; 36(3):442-447. PubMed ID: 31800936
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 18.