These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

106 related articles for article (PubMed ID: 31879966)

  • 1. Monte Carlo study for correcting the broadened line-scan profile in scanning electron microscopy.
    Zhang P
    J Microsc; 2020 Jan; 277(1):23-31. PubMed ID: 31879966
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Monte Carlo simulation of CD-SEM images for linewidth and critical dimension metrology.
    Li YG; Zhang P; Ding ZJ
    Scanning; 2013; 35(2):127-39. PubMed ID: 22887037
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Two-dimensional simulation and modeling in scanning electron microscope imaging and metrology research.
    Postek MT; Vladár AE; Lowney JR; Keery WJ
    Scanning; 2002; 24(4):179-85. PubMed ID: 12166805
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Monte Carlo simulation of scanning electron microscope image of sidewall shape for linewidth measurement.
    Xiao SM; Zhang ZM; Li HM; Ding ZJ
    J Nanosci Nanotechnol; 2009 Feb; 9(2):1655-8. PubMed ID: 19441593
    [TBL] [Abstract][Full Text] [Related]  

  • 5. X-Ray Lithography Mask Metrology: Use of Transmitted Electrons in an SEM for Linewidth Measurement.
    Postek MT; Lowney JR; Vladar AE; Keery WJ; Marx E; Larrabee RD
    J Res Natl Inst Stand Technol; 1993; 98(4):415-445. PubMed ID: 28053482
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Monte Carlo Simulation on the CD-SEM Images of SiO2/Si Systems.
    Zhang P
    Microsc Microanal; 2019 Aug; 25(4):849-858. PubMed ID: 31046846
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Determination of the initial beam parameters in Monte Carlo linac simulation.
    Aljarrah K; Sharp GC; Neicu T; Jiang SB
    Med Phys; 2006 Apr; 33(4):850-8. PubMed ID: 16696460
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Inference of the optimal pretarget electron beam parameters in a Monte Carlo virtual linac model through simulated annealing.
    Bush K; Zavgorodni S; Beckham W
    Med Phys; 2009 Jun; 36(6):2309-19. PubMed ID: 19610319
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Electron beam broadening in electron-transparent samples at low electron energies.
    Hugenschmidt M; Müller E; Gerthsen D
    J Microsc; 2019 Jun; 274(3):150-157. PubMed ID: 31001840
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Monte Carlo linear accelerator simulation of megavoltage photon beams: independent determination of initial beam parameters.
    Almberg SS; Frengen J; Kylling A; Lindmo T
    Med Phys; 2012 Jan; 39(1):40-7. PubMed ID: 22225273
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Exploring the accurate size measurement method for two typical nanostructures basing on SEM imaging.
    Zhang P
    Micron; 2019 Nov; 126():102756. PubMed ID: 31563080
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Analytical equations for CT dose profiles derived using a scatter kernel of Monte Carlo parentage with broad applicability to CT dosimetry problems.
    Dixon RL; Boone JM
    Med Phys; 2011 Jul; 38(7):4251-64. PubMed ID: 21859027
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A Monte Carlo-based dosimetric characterization of Esteya
    Valdes-Cortez C; Niatsetski Y; Perez-Calatayud J; Ballester F; Vijande J
    Med Phys; 2019 Jan; 46(1):356-369. PubMed ID: 30390317
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Scanning electron microscope measurement of width and shape of 10nm patterned lines using a JMONSEL-modeled library.
    Villarrubia JS; Vladár AE; Ming B; Kline RJ; Sunday DF; Chawla JS; List S
    Ultramicroscopy; 2015 Jul; 154():15-28. PubMed ID: 25747180
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of film measurements and Monte Carlo simulations of dose delivered with very high-energy electron beams in a polystyrene phantom.
    Bazalova-Carter M; Liu M; Palma B; Dunning M; McCormick D; Hemsing E; Nelson J; Jobe K; Colby E; Koong AC; Tantawi S; Dolgashev V; Maxim PG; Loo BW
    Med Phys; 2015 Apr; 42(4):1606-13. PubMed ID: 25832051
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Conventional vs. model-based measurement of patterned line widths from scanning electron microscopy profiles.
    Salvat-Pujol F; Villarrubia JS
    Ultramicroscopy; 2019 Nov; 206():112819. PubMed ID: 31421625
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Depth-correlated backscattered electron signal intensity for 3D-profile measurement of high aspect ratio holes.
    Sun W; Ohta H; Ninomiya T; Goto Y; Sohta Y
    Microscopy (Oxf); 2019 Oct; 68(5):385-394. PubMed ID: 31386150
    [TBL] [Abstract][Full Text] [Related]  

  • 18. An EGS Monte Carlo model for Varian TrueBEAM treatment units: Commissioning and experimental validation of source parameters.
    López-Sánchez M; Pérez-Fernández M; Fandiño JM; Teijeiro A; Luna-Vega V; Gómez-Fernández N; Gómez F; González-Castaño DM
    Phys Med; 2019 Aug; 64():81-88. PubMed ID: 31515039
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Characteristics of elliptical sources in BEAMnrc Monte Carlo system: implementation and application.
    Kim S
    Med Phys; 2009 Apr; 36(4):1046-52. PubMed ID: 19472609
    [TBL] [Abstract][Full Text] [Related]  

  • 20.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 6.