These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

274 related articles for article (PubMed ID: 31881914)

  • 1. Tape suture for stabilization of incomplete posterior pelvic ring fractures-biomechanical analysis of a new minimally invasive treatment for incomplete lateral compression pelvic ring fractures.
    Becker CA; Kussmaul AC; Suero EM; Regauer M; Woiczinski M; Braun C; Flatz W; Pieske O; Kammerlander C; Boecker W; Greiner A
    J Orthop Surg Res; 2019 Dec; 14(1):465. PubMed ID: 31881914
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Biomechanical comparison of minimally invasive treatment options for Type C unstable fractures of the pelvic ring.
    Cavalcanti Kußmaul A; Greiner A; Kammerlander C; Zeckey C; Woiczinski M; Thorwächter C; Gennen C; Kleber C; Böcker W; Becker CA
    Orthop Traumatol Surg Res; 2020 Feb; 106(1):127-133. PubMed ID: 31864961
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Minimally invasive screw fixation is as stable as anterior plating in acetabular T-Type fractures - a biomechanical study.
    Becker CA; Kammerlander C; Cavalcanti Kußmaul A; Dotzauer F; Woiczinski M; Rubenbauer B; Sommer F; Linhart C; Weidert S; Zeckey C; Greiner A
    Orthop Traumatol Surg Res; 2018 Nov; 104(7):1055-1061. PubMed ID: 30179721
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Minimal-invasive stabilization of anterior pelvic ring fractures with retrograde transpubic screws.
    Rommens PM; Graafen M; Arand C; Mehling I; Hofmann A; Wagner D
    Injury; 2020 Feb; 51(2):340-346. PubMed ID: 31879175
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Sacroiliac versus transiliac-transsacral screw osteosynthesis in osteoporotic pelvic fractures: a biomechanical comparison.
    Cintean R; Fritzsche C; Zderic I; Gueorguiev-Rüegg B; Gebhard F; Schütze K
    Eur J Trauma Emerg Surg; 2023 Dec; 49(6):2553-2560. PubMed ID: 37535095
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Posterior screw fixation in rotationally unstable pelvic ring injuries.
    Osterhoff G; Ossendorf C; Wanner GA; Simmen HP; Werner CM
    Injury; 2011 Oct; 42(10):992-6. PubMed ID: 21529802
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Minimally invasive stabilisation of posterior pelvic ring instabilities with pedicle screws connected to a transverse rod.
    Wang H; Fu YH; Ke C; Zhuang Y; Zhang K; Wei X; Li Z; Lei JL; Zhang BF; Liu P
    Int Orthop; 2018 Mar; 42(3):681-686. PubMed ID: 29238871
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Modified less invasive anterior subcutaneous fixator for unstable Tile-C-pelvic ring fractures: a biomechanical study.
    Becker CA; Kammerlander C; Kußmaul AC; Woiczinski M; Thorwächter C; Zeckey C; Sommer F; Linhart C; Weidert S; Suero EM; Böcker W; Greiner A
    Biomed Eng Online; 2019 Mar; 18(1):38. PubMed ID: 30925898
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Does Cement Augmentation of the Sacroiliac Screw Lead to Superior Biomechanical Results for Fixation of the Posterior Pelvic Ring? A Biomechanical Study.
    Lodde MF; Katthagen JC; Schopper CO; Zderic I; Richards RG; Gueorguiev B; Raschke MJ; Hartensuer R
    Medicina (Kaunas); 2021 Dec; 57(12):. PubMed ID: 34946313
    [No Abstract]   [Full Text] [Related]  

  • 10. Biomechanical stability of sacroiliac screw osteosynthesis with and without cement augmentation.
    Suero EM; Greiner A; Becker CA; Cavalcanti Kußmaul A; Weidert S; Pfeufer D; Woiczinski M; Braun C; Flatz W; Böcker W; Kammerlander C
    Injury; 2021 Oct; 52(10):2707-2711. PubMed ID: 32033807
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Contributions of Pubic Rami Fracture Morphology and Fixation to Pelvic Ring Stability in Type 1 Lateral Compression Injuries: A Biomechanical Cadaveric Study.
    Marenghi N; Bang KE; Danelson K; Hasty E; Snoap T; Taylor L; Okundia S; Kelly E; Teater R; Halvorson J; Carroll E
    J Orthop Trauma; 2022 Feb; 36(Suppl 2):S7-S11. PubMed ID: 35061644
    [TBL] [Abstract][Full Text] [Related]  

  • 12. 2D versus 3D fluoroscopy-based navigation in posterior pelvic fixation: review of the literature on current technology.
    Thakkar SC; Thakkar RS; Sirisreetreerux N; Carrino JA; Shafiq B; Hasenboehler EA
    Int J Comput Assist Radiol Surg; 2017 Jan; 12(1):69-76. PubMed ID: 27503119
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Biomechanical comparative study on external fixators of new configurations in the treatment of Tile C pelvic injury.
    Zhao Y; Ma Y; Wu H; Lian W; Li W; Jiang W
    Sci Rep; 2024 Apr; 14(1):9544. PubMed ID: 38664538
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Biomechanical comparison of posterior pelvic ring fixation.
    Yinger K; Scalise J; Olson SA; Bay BK; Finkemeier CG
    J Orthop Trauma; 2003 Aug; 17(7):481-7. PubMed ID: 12902785
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Biomechanical comparison of posterior internal fixation techniques for unstable pelvic fractures.
    Comstock CP; van der Meulen MC; Goodman SB
    J Orthop Trauma; 1996; 10(8):517-22. PubMed ID: 8915911
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A biomechanical comparison of superior ramus plating versus intramedullary screw fixation for unstable lateral compression pelvic ring injuries
    Hempen EC; Wheatley BM; Schimoler PJ; Kharlamov A; Melvin PR; Miller MC; Altman GT; Altman DT; Westrick ER
    Injury; 2022 Dec; 53(12):3899-3903. PubMed ID: 36182593
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Does Posterior Fixation of Partially Unstable Open-Book Pelvic Ring Injuries Decrease Symphyseal Plate Failure? A Biomechanical Study.
    Metz RM; Bledsoe JG; Moed BR
    J Orthop Trauma; 2018 Feb; 32 Suppl 1():S18-S24. PubMed ID: 29373447
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of cannulated compression headless screws as an alternative implant for superior pubic ramus fracture fixation: a biomechanical study.
    Berk T; Zderic I; Schwarzenberg P; Pastor T; Lesche F; Halvachizadeh S; Richards RG; Gueorguiev B; Pape HC
    Int Orthop; 2023 Apr; 47(4):1079-1087. PubMed ID: 36749374
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Minimally invasive transiliac plate osteosynthesis for type C injuries of the pelvic ring: a clinical and radiological follow-up.
    Krappinger D; Larndorfer R; Struve P; Rosenberger R; Arora R; Blauth M
    J Orthop Trauma; 2007 Oct; 21(9):595-602. PubMed ID: 17921833
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Iliosacral screw fixation of the unstable pelvic ring injuries.
    Rysavý M; Pavelka T; Khayarin M; Dzupa V
    Acta Chir Orthop Traumatol Cech; 2010 Jun; 77(3):209-14. PubMed ID: 20619112
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.