BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

205 related articles for article (PubMed ID: 31888751)

  • 41. Endoscopic ultrasound-guided pancreatic fluid collections' transmural drainage outcomes in 100 consecutive cases of pseudocysts and walled off necrosis: a single-centre experience from the United Kingdom.
    Shekhar C; Maher B; Forde C; Mahon BS
    Scand J Gastroenterol; 2018 May; 53(5):611-615. PubMed ID: 29117722
    [TBL] [Abstract][Full Text] [Related]  

  • 42. The safety and efficacy of a new 20-mm lumen apposing metal stent (lams) for the endoscopic treatment of pancreatic and peripancreatic fluid collections: a large international, multicenter study.
    Anderloni A; Fabbri C; Nieto J; Uwe W; Dollhopf M; Aparicio JR; Perez-Miranda M; Tarantino I; Arlt A; Vleggaar F; Vanbiervliet G; Hampe J; Kahaleh M; Vila JJ; Dayyeh BKA; Storm AC; Fugazza A; Binda C; Charachon A; Sevilla-Ribota S; Tyberg A; Robert M; Wani S; Repici A; Sethi A; Khashab MA; Kunda R
    Surg Endosc; 2021 Apr; 35(4):1741-1748. PubMed ID: 32323015
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Lumen-apposing-metal stent misdeployment in endoscopic ultrasound-guided drainages: A systematic review focusing on issues and rescue management.
    Armellini E; Metelli F; Anderloni A; Cominardi A; Aragona G; Marini M; Pace F
    World J Gastroenterol; 2023 Jun; 29(21):3341-3361. PubMed ID: 37377584
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Lumen-apposing metal stents in management of pancreatic fluid collections: The nobody's land of removal timing.
    De Angelis CG; Venezia L; Cortegoso Valdivia P; Rizza S; Bruno M; Pellicano R
    Saudi J Gastroenterol; 2019; 25(6):335-340. PubMed ID: 31823862
    [TBL] [Abstract][Full Text] [Related]  

  • 45. EUS-guided drainage of pancreatic fluid collections using lumen apposing metal stents: An international, multicenter experience.
    Kumta NA; Tyberg A; Bhagat VH; Siddiqui AA; Kowalski TE; Loren DE; Desai AP; Sarkisian AM; Brown EG; Karia K; Gaidhane M; Kedia P; Tarnasky PR; Patel U; Adler D; Taylor LJ; Petrone M; Arcidiacono P; Yachimski PS; Weine D; Sundararajan S; Deprez PH; Mouradides C; Ho S; Javed S; Easler JJ; Raijman I; Vazquez-Sequeiros E; Sawhney M; Berzin TM; Kahaleh M
    Dig Liver Dis; 2019 Nov; 51(11):1557-1561. PubMed ID: 31272934
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Short- and long-term results of endoscopic ultrasound-guided transmural drainage for pancreatic pseudocysts and walled-off necrosis.
    Watanabe Y; Mikata R; Yasui S; Ohyama H; Sugiyama H; Sakai Y; Tsuyuguchi T; Kato N
    World J Gastroenterol; 2017 Oct; 23(39):7110-7118. PubMed ID: 29093619
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Lumen-apposing metal stents versus traditional self-expanding metal stents for endoscopic ultrasound-guided drainage of pancreatic fluid collections: a systematic review and meta-analysis.
    Tian Y; Yin C; Ma Y; Fu G; Liu R; Ran H; Pan T; Xiao Y; Wen X
    Surg Endosc; 2024 Feb; 38(2):586-596. PubMed ID: 38151677
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Prospective multicenter international study on the outcomes of a newly developed self-approximating lumen-apposing metallic stent for drainage of pancreatic fluid collections and endoscopic necrosectomy.
    Teoh AYB; Bapaye A; Lakhtakia S; Ratanachu T; Reknimitr R; Chan SM; Choi HJ; Gadhikar HP; Kongkam P; Korrapati SK; Lee YN; Medarapalem J; Ridtitid W; Moon JH
    Dig Endosc; 2020 Mar; 32(3):391-398. PubMed ID: 31343773
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Comparison of three different stents for endoscopic ultrasound-guided drainage of pancreatic fluid collection: A large retrospective study.
    Wang Z; Zhao S; Meng Q; Wang S; Chen Y; Wang F; Li Q; Yao J; Du Y; Jin Z; Bai Y; Li Z; Wang D
    J Gastroenterol Hepatol; 2019 Apr; 34(4):791-798. PubMed ID: 30475420
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Comparative outcomes of endoscopic ultrasound-guided lumen-apposing mental stents drainage for pancreatic pseudocysts and walled-off necrosis: Case series and meta-analysis.
    Li J; Zhang Q; Zhou A; Zhao G; Li P
    Chronic Dis Transl Med; 2021 Sep; 7(3):157-168. PubMed ID: 34505016
    [TBL] [Abstract][Full Text] [Related]  

  • 51. EUS-Guided Gallbladder Drainage Using an Improved Self-Expandable Covered Metal Stent with Anti-Stent Migration System (with Video).
    Ogura T; Nishioka N; Yamada M; Yamada T; Higuchi K
    Dig Dis; 2021; 39(2):150-155. PubMed ID: 32512575
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Three-way comparative study of endoscopic ultrasound-guided transmural gallbladder drainage using lumen-apposing metal stents versus endoscopic transpapillary drainage versus percutaneous cholecystostomy for gallbladder drainage in high-risk surgical patients with acute cholecystitis: clinical outcomes and success in an International, Multicenter Study.
    Siddiqui A; Kunda R; Tyberg A; Arain MA; Noor A; Mumtaz T; Iqbal U; Loren DE; Kowalski TE; Adler DG; Saumoy M; Gaidhane M; Mallery S; Christiansen EM; Nieto J; Kahaleh M
    Surg Endosc; 2019 Apr; 33(4):1260-1270. PubMed ID: 30209610
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Safety and Efficacy of Long-Term Transmural Plastic Stent Placement After Removal of Lumen Apposing Metal Stent in Resolved Pancreatic Fluid Collections with Duct Disconnection at Head/Neck of Pancreas.
    Rana SS; Sharma R; Sharma G; Gupta R
    Dig Dis Sci; 2023 Aug; 68(8):3436-3441. PubMed ID: 37269369
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Equivalent efficacy and safety of plastic stents and lumen-apposing metal stents in the treatment of peripancreatic fluid collections: a prospective cohort study.
    Khodakaram K; Bratlie SO; Hedenström P; Sadik R
    Ann Gastroenterol; 2024; 37(3):362-370. PubMed ID: 38779636
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Endoscopic ultrasound-guided transmural drainage of walled-off pancreatic necrosis in patients with portal hypertension and intra-abdominal collaterals.
    Rana SS; Sharma R; Ahmed SU; Gupta R
    Indian J Gastroenterol; 2017 Sep; 36(5):400-404. PubMed ID: 28971378
    [TBL] [Abstract][Full Text] [Related]  

  • 56. What is the Impact of the Proportion of Solid Necrotic Content on the Number of Necrosectomies during EUS-Guided Drainage using Lumen-Apposing Metallic Stents of Pancreatic Walled-off Necrosis ?
    Seicean A; Pojoga C; Mostean O; Bolboaca S; Ilie M; Rimbas M; Gheorghiu M; Lucaciu L; Bartos A; Al Hajjar N; Sandru V; Constantinescu G; Seicean R
    J Gastrointestin Liver Dis; 2020 Dec; 29(4):623-628. PubMed ID: 33331355
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Comparative Effectiveness of Lumen-Apposing Metal Stents and Plastic Stents for the Treatment of Pancreatic Walled-Off Necrosis: A Meta-analysis.
    Calo NC; Bishay K; Yaghoobi M; Yuan Y; Mosko J; May G; Chen YI; Teshima C
    J Can Assoc Gastroenterol; 2022 Apr; 5(2):68-78. PubMed ID: 35368320
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Comparison Between Lumen-Apposing Metal Stents and Plastic Stents in Endoscopic Ultrasound-Guided Drainage of Pancreatic Fluid Collection: A Meta-analysis and Systematic Review.
    Lyu Y; Li T; Wang B; Cheng Y; Chen L; Zhao S
    Pancreas; 2021 Apr; 50(4):571-578. PubMed ID: 33939671
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Endoscopic ultrasound-guided drainage of pancreatic walled-off necrosis using 20-mm versus 15-mm lumen-apposing metal stents: an international, multicenter, case-matched study.
    Parsa N; Nieto JM; Powers P; Mitsuhashi S; Abdelqader A; Hadzinakos G; Anderloni AA; Fugazza A; James TW; Arlt A; Ellrichmann M; Aparicio JR; Trindade AJ; Stevens TK; Chahal P; Shah SL; Messallam AA; Lang G; Fejleh MP; Benias PC; Sejpal DV; Jones J; Mir FF; Aghaie Meybodi M; Ichkhanian Y; Vosoughi K; Novikov AA; Irani SS; Pawa R; Ahmed AM; Sedarat A; Hsueh W; Hampe J; Sharaiha RZ; Berzin TM; Willingham FF; Kushnir VM; Brewer Gutierrez OI; Ngamruengphong S; Huggett MT; Baron TH; Repici A; Adler DG; Nasr JT; Kowalski TE; Kumbhari V; Singh VK; Khashab MA
    Endoscopy; 2020 Mar; 52(3):211-219. PubMed ID: 32000275
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Protocol of early lumen apposing metal stent removal for pseudocysts and walled off necrosis avoids bleeding complications.
    Ahmad W; Fehmi SA; Savides TJ; Anand G; Chang MA; Kwong WT
    Scand J Gastroenterol; 2020 Feb; 55(2):242-247. PubMed ID: 31942808
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.