These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

175 related articles for article (PubMed ID: 3189157)

  • 1. Noninvasive, quantitative respirator fit testing through dynamic pressure measurement.
    Carpenter DR; Willeke K
    Am Ind Hyg Assoc J; 1988 Oct; 49(10):485-91. PubMed ID: 3189157
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Quantitative respirator fit testing: dynamic pressure versus aerosol measurement.
    Carpenter DR; Willeke K
    Am Ind Hyg Assoc J; 1988 Oct; 49(10):492-6. PubMed ID: 3189158
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The effect of aerosol size distribution and measurement method on respirator fit.
    Holton PM; Willeke K
    Am Ind Hyg Assoc J; 1987 Oct; 48(10):855-60. PubMed ID: 3687730
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Experiments supporting the use of ambient aerosols for quantitative respirator fit testing.
    Ernstberger HG; Gall RB; Turok CW
    Am Ind Hyg Assoc J; 1988 Dec; 49(12):613-9. PubMed ID: 3213815
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A feasibility study of quantitative respirator fit testing by controlled negative pressure.
    Crutchfield CD; Eroh MP; Van Ert MD
    Am Ind Hyg Assoc J; 1991 Apr; 52(4):172-6. PubMed ID: 2069125
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Fit-testing for firefighters.
    Brickman CP
    Occup Health Saf; 1999 Jan; 68(1):56-8. PubMed ID: 9891408
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Variation in quantitative respirator fit factors due to fluctuations in leak size during fit testing.
    Krishnan U; Willeke K; Juozaitis A; Myojo T; Talaska G; Shukla R
    Am Ind Hyg Assoc J; 1994 Apr; 55(4):309-14. PubMed ID: 8209835
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Particle size-dependent leakage and losses of aerosols in respirators.
    Holton PM; Tackett DL; Willeke K
    Am Ind Hyg Assoc J; 1987 Oct; 48(10):848-54. PubMed ID: 3687729
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Respiratory protection against Mycobacterium tuberculosis: quantitative fit test outcomes for five type N95 filtering-facepiece respirators.
    Lee K; Slavcev A; Nicas M
    J Occup Environ Hyg; 2004 Jan; 1(1):22-8. PubMed ID: 15202153
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Capability of respirator wearers to detect aerosolized qualitative fit test agents (sweetener and Bitrex) with known fixed leaks.
    McKay RT; Davies E
    Appl Occup Environ Hyg; 2000 Jun; 15(6):479-84. PubMed ID: 10853288
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A comparison of controlled negative pressure and aerosol quantitative respirator fit test systems by using fixed leaks.
    Crutchfield CD; Murphy RW; Van Ert MD
    Am Ind Hyg Assoc J; 1991 Jun; 52(6):249-51. PubMed ID: 1858667
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The effect of pressure drop on respirator faceseal leakage.
    Janssen L; Weber R
    J Occup Environ Hyg; 2005 Jul; 2(7):335-40. PubMed ID: 16020096
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Performance of dust respirators with facial seal leaks: I. Experimental.
    Hinds WC; Kraske G
    Am Ind Hyg Assoc J; 1987 Oct; 48(10):836-41. PubMed ID: 3687728
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effect of leak location on measured respirator fit.
    Crutchfield CD; Park DL
    Am Ind Hyg Assoc J; 1997 Jun; 58(6):413-7. PubMed ID: 9183835
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Simplified pressure method for respirator fit testing.
    Han D; Xu M; Foo S; Pilacinski W; Willeke K
    Am Ind Hyg Assoc J; 1991 Aug; 52(8):305-8. PubMed ID: 1927906
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Respirator protection factors: Part II-protection factors of supplied-air respirators.
    Hack AL; Bradley OD; Trujillo A
    Am Ind Hyg Assoc J; 1980 May; 41(5):376-81. PubMed ID: 7415964
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A new sampling technique that allows quantitative fit testing by using the employee's own respirator.
    Johnson BR; Bjork KA; Weed JB
    Am Ind Hyg Assoc J; 1992 Dec; 53(12):776-9. PubMed ID: 1471599
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Quantitative fit testing of personnel utilizing a mouthpiece respirator.
    Packard LH; Brady HL; Schumm OF
    Am Ind Hyg Assoc J; 1978 Sep; 39(9):723-30. PubMed ID: 727118
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Performance of dust respirators with facial seal leaks: II. Predictive model.
    Hinds WC; Bellin P
    Am Ind Hyg Assoc J; 1987 Oct; 48(10):842-7. PubMed ID: 3318364
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of saccharin qualitative fitting test for respirators.
    Marsh JL
    Am Ind Hyg Assoc J; 1984 Jun; 45(6):371-6. PubMed ID: 6741791
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.