BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

374 related articles for article (PubMed ID: 31892319)

  • 21. Clinical evaluation of internal hemodiafiltration (iHDF): a diffusive-convective technique performed with internal filtration enhanced high-flux dialyzers.
    Lucchi L; Fiore GB; Guadagni G; Perrone S; Malaguti V; Caruso F; Fumero R; Albertazzi A
    Int J Artif Organs; 2004 May; 27(5):414-9. PubMed ID: 15202820
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Effectiveness of Haemodiafiltration with Heat Sterilized High-Flux Polyphenylene HF Dialyzer in Reducing Free Light Chains in Patients with Myeloma Cast Nephropathy.
    Rousseau-Gagnon M; Agharazii M; De Serres SA; Desmeules S
    PLoS One; 2015; 10(10):e0140463. PubMed ID: 26466100
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Efficacy of medium cut-off dialyzers and comparison with high-flux dialyzers in patients on maintenance hemodialysis: A systematic review and meta-analysis.
    Yang J; Ke G; Liao Y; Guo Y; Gao X
    Ther Apher Dial; 2022 Aug; 26(4):756-768. PubMed ID: 34773675
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Removal of the protein-bound solute p-cresol by convective transport: a randomized crossover study.
    Bammens B; Evenepoel P; Verbeke K; Vanrenterghem Y
    Am J Kidney Dis; 2004 Aug; 44(2):278-85. PubMed ID: 15264186
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Comparison between on-line high-efficiency hemodiafiltration and conventional high-flux hemodialysis for polyclonal free light chain removal.
    Lamy T; Henri P; Lobbedez T; Comby E; Ryckelynck JP; Ficheux M
    Blood Purif; 2014; 37(2):93-8. PubMed ID: 24603634
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Comparison of the medium cutoff dialyzer and postdilution hemodiafiltration on the removal of small and middle molecule uremic toxins.
    Kim CS; Joo SY; Choi HS; Bae EH; Ma SK; Kim SW
    Kidney Res Clin Pract; 2023 Nov; 42(6):712-722. PubMed ID: 37448285
    [TBL] [Abstract][Full Text] [Related]  

  • 27. The effect of high-volume online haemodiafiltration on nutritional status and body composition: the ProtEin Stores prEservaTion (PESET) study.
    Molina P; Vizcaíno B; Molina MD; Beltrán S; González-Moya M; Mora A; Castro-Alonso C; Kanter J; Ávila AI; Górriz JL; Estañ N; Pallardó LM; Fouque D; Carrero JJ
    Nephrol Dial Transplant; 2018 Jul; 33(7):1223-1235. PubMed ID: 29370428
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Retention of beneficial molecules and coagulation factors during haemodialysis and haemodiafiltration.
    Voigt M; Gebert M; Haug U; Hulko M; Storr M; Boschetti-de-Fierro A; Beck W; Krause B
    Sci Rep; 2019 Apr; 9(1):6370. PubMed ID: 31015539
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Comparative Effectiveness between Expanded Hemodialysis (Hemodialysis Using a Medium Cut-Off Dialyzer) and Mixed-Dilution Online Hemodiafiltration Using a High-Flux Dialyzer in Removing Middle-Molecule Uremic Toxins.
    Eiamcharoenying J; Takkavatakarn K; Chariyavilaskul P; Susantitaphong P; Eiam-Ong S; Tiranathanagul K
    Blood Purif; 2022; 51(11):923-931. PubMed ID: 35279655
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Comparison of four medium cut-off dialyzers.
    Maduell F; Broseta JJ; Rodríguez-Espinosa D; Del Risco J; Rodas LM; Arias-Guillén M; Vera M; Fontseré N; Salgado MDC; Rico N
    Clin Kidney J; 2022 Dec; 15(12):2292-2299. PubMed ID: 36381368
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Mid-dilution on-line haemodiafiltration in a standard dialyser configuration.
    Krieter DH; Collins G; Summerton J; Spence E; Moragues HL; Canaud B
    Nephrol Dial Transplant; 2005 Jan; 20(1):155-60. PubMed ID: 15522903
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Comparative analysis of procoagulatory activity of haemodialysis, haemofiltration and haemodiafiltration with a polysulfone membrane (APS) and with different modes of enoxaparin anticoagulation.
    Klingel R; Schaefer M; Schwarting A; Himmelsbach F; Altes U; Uhlenbusch-Körwer I; Hafner G
    Nephrol Dial Transplant; 2004 Jan; 19(1):164-70. PubMed ID: 14671052
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Improved β2-Microglobulin and Phosphorous Removal with Expanded Hemodialysis and Online Hemodiafiltration versus High-Flux Hemodialysis: A Cross-Over Randomized Clinical Trial.
    Vega-Vega O; Caballero-Islas AE; Del Toro-Cisneros N; Hernandez-Ordoñez SÓ; Arvizu-Hernández M; Martínez-Rueda A; Camacho-Colin D; Gómez-Correa LL; Correa-Rotter R
    Blood Purif; 2023; 52(7-8):712-720. PubMed ID: 37473747
    [TBL] [Abstract][Full Text] [Related]  

  • 34. High-volume online haemodiafiltration improves erythropoiesis-stimulating agent (ESA) resistance in comparison with low-flux bicarbonate dialysis: results of the REDERT study.
    Panichi V; Scatena A; Rosati A; Giusti R; Ferro G; Malagnino E; Capitanini A; Piluso A; Conti P; Bernabini G; Migliori M; Caiani D; Tetta C; Casani A; Betti G; Pizzarelli F
    Nephrol Dial Transplant; 2015 Apr; 30(4):682-9. PubMed ID: 25385719
    [TBL] [Abstract][Full Text] [Related]  

  • 35. On-line haemodiafiltration. Remarkable removal of beta2-microglobulin. Long-term clinical observations.
    Lornoy W; Becaus I; Billiouw JM; Sierens L; Van Malderen P; D'Haenens P
    Nephrol Dial Transplant; 2000; 15 Suppl 1():49-54. PubMed ID: 10737167
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Clinical Performance Assessment of CorDiax Filters in Hemodialysis and Hemodiafiltration.
    Potier J; Bowry S; Canaud B
    Contrib Nephrol; 2017; 189():237-245. PubMed ID: 27951574
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Cost comparison of online haemodiafiltration with high-flux haemodialysis.
    Oates T; Cross J; Davenport A
    J Nephrol; 2012; 25(2):192-7. PubMed ID: 22038334
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Effect of haemodiafiltration vs conventional haemodialysis on growth and cardiovascular outcomes in children - the HDF, heart and height (3H) study.
    Shroff R; Bayazit A; Stefanidis CJ; Askiti V; Azukaitis K; Canpolat N; Agbas A; Anarat A; Aoun B; Bakkaloglu S; Bhowruth D; Borzych-Dużałka D; Bulut IK; Büscher R; Dempster C; Duzova A; Habbig S; Hayes W; Hegde S; Krid S; Licht C; Litwin M; Mayes M; Mir S; Nemec R; Obrycki L; Paglialonga F; Picca S; Ranchin B; Samaille C; Shenoy M; Sinha M; Smith C; Spasojevic B; Vidal E; Vondrák K; Yilmaz A; Zaloszyc A; Fischbach M; Schaefer F; Schmitt CP
    BMC Nephrol; 2018 Aug; 19(1):199. PubMed ID: 30097064
    [TBL] [Abstract][Full Text] [Related]  

  • 39. A Pharmacokinetic Study Comparing the Clearance of Vancomycin during Haemodialysis Using Medium Cut-Off Membrane (Theranova) and High-Flux Membranes (Revaclear).
    Allawati H; Dallas L; Nair S; Palmer J; Thaikandy S; Hutchison C
    Toxins (Basel); 2020 May; 12(5):. PubMed ID: 32408589
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Albumin losses during hemodiafiltration: all dialyzers are not created equal - a case report.
    Cuvelier C; Tintillier M; Migali G; Van Ende C; Pochet JM
    BMC Nephrol; 2019 Oct; 20(1):392. PubMed ID: 31660886
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 19.