These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

198 related articles for article (PubMed ID: 31899542)

  • 1. Ventricular tachycardia oversensing in S-ICD patients: Case-based brief review.
    Zoppo F; Mangiameli D; Perazza L; Lardieri G
    Pacing Clin Electrophysiol; 2020 Feb; 43(2):261-265. PubMed ID: 31899542
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Reduction of ICD shock burden by eliminating back-up pacing induced ventricular tachyarrhythmias.
    Theis C; Mollnau H; Sonnenschein S; Konrad T; Himmrich E; Bock K; Schulz E; Kämpfner D; Gerhardt S; Quesada Ocete B; Münzel T; Rostock T
    J Cardiovasc Electrophysiol; 2014 Aug; 25(8):889-895. PubMed ID: 24654876
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Implantable defibrillator event rates in patients with idiopathic dilated cardiomyopathy, nonsustained ventricular tachycardia on Holter and a left ventricular ejection fraction below 30%.
    Grimm W; Hoffmann J Jü; Müller HH; Maisch B
    J Am Coll Cardiol; 2002 Mar; 39(5):780-7. PubMed ID: 11869841
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Association left ventricular lead and ventricular arrhythmias after upgrade to cardiac resynchronization therapy in patients with implantable cardioverter defibrillators.
    Kawamura M; Arai S; Yoshikawa K; Gokan T; Ogawa K; Ochi A; Onishi Y; Munetsugu Y; Ito H; Onuki T; Kobayashi Y; Shinke T
    Clin Cardiol; 2019 Jul; 42(7):670-677. PubMed ID: 31056759
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Multicenter investigation of an implantable cardioverter-defibrillator algorithm to detect oversensing.
    Welte N; Strik M; Eschalier R; Mondoly P; Defaye P; Frontera A; Ritter P; Haïssaguerre M; Ploux S; Koneru J; Ellenbogen KA; Bordachar P
    Heart Rhythm; 2017 Jul; 14(7):1008-1015. PubMed ID: 28323174
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Efficacy of implantable cardioverter defibrillators in young patients with catecholaminergic polymorphic ventricular tachycardia: success depends on substrate.
    Miyake CY; Webster G; Czosek RJ; Kantoch MJ; Dubin AM; Avasarala K; Atallah J
    Circ Arrhythm Electrophysiol; 2013 Jun; 6(3):579-87. PubMed ID: 23667268
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Isoelectric PVCs diagnosed with a monitor with simultaneous ECG, and ICD intracardiac electrogram and marker channels.
    Scher DL; Man DC; Edery T; Lu S
    Pacing Clin Electrophysiol; 2009 Jan; 32(1):137-9. PubMed ID: 19140925
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Two Limitations of Subcutaneous Implantable Cardioverter Defibrillator in the Same Patient Warranting Its Explant.
    Dhawan R; Ahmad M; Jhand A; Kanwal S; Jamil A; Khan F
    Am J Case Rep; 2021 Apr; 22():e928983. PubMed ID: 33911064
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Combined third-generation implantable cardioverter defibrillator with permanent unipolar pacemakers: preliminary observations.
    Haffajee C; Casavant D; Desai P; Moon R; Voukydis P; Pacetti P
    Pacing Clin Electrophysiol; 1996 Feb; 19(2):136-42. PubMed ID: 8834682
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Implantable cardioverter-defibrillator therapy in the absence of significant symptoms. Rhythm diagnosis and management aided by stored electrogram analysis.
    Hook BG; Callans DJ; Kleiman RB; Flores BT; Marchlinski FE
    Circulation; 1993 Jun; 87(6):1897-906. PubMed ID: 8504502
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Inappropriate shock delivery by implantable defibrillators with dual chamber pacing during nonsustained ventricular tachycardia in patients with heart block.
    Sra J; Akhtar M
    Pacing Clin Electrophysiol; 2000 Jun; 23(6):1054-6. PubMed ID: 10879396
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Acute and 3-Month Performance of a Communicating Leadless Antitachycardia Pacemaker and Subcutaneous Implantable Defibrillator.
    Tjong FVY; Brouwer TF; Koop B; Soltis B; Shuros A; Schmidt B; Swackhamer B; Quast AEB; Wilde AAM; Burke MC; Knops RE
    JACC Clin Electrophysiol; 2017 Dec; 3(13):1487-1498. PubMed ID: 29759829
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Significance of supraventricular tachyarrhythmias in patients with implanted pacing cardioverter defibrillators.
    Schmitt C; Montero M; Melichercik J
    Pacing Clin Electrophysiol; 1994 Mar; 17(3 Pt 1):295-302. PubMed ID: 7513854
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Outcomes of defibrillator therapy in catecholaminergic polymorphic ventricular tachycardia.
    Roses-Noguer F; Jarman JW; Clague JR; Till J
    Heart Rhythm; 2014 Jan; 11(1):58-66. PubMed ID: 24120999
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Dofetilide reduces the frequency of ventricular arrhythmias and implantable cardioverter defibrillator therapies.
    Baquero GA; Banchs JE; Depalma S; Young SK; Penny-Peterson ED; Samii SM; Wolbrette DL; Naccarelli GV; Gonzalez MD
    J Cardiovasc Electrophysiol; 2012 Mar; 23(3):296-301. PubMed ID: 21955243
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Strategic programming of detection and therapy parameters in implantable cardioverter-defibrillators reduces shocks in primary prevention patients: results from the PREPARE (Primary Prevention Parameters Evaluation) study.
    Wilkoff BL; Williamson BD; Stern RS; Moore SL; Lu F; Lee SW; Birgersdotter-Green UM; Wathen MS; Van Gelder IC; Heubner BM; Brown ML; Holloman KK;
    J Am Coll Cardiol; 2008 Aug; 52(7):541-50. PubMed ID: 18687248
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An "inappropriately appropriate" shock in a subcutaneous implantable cardioverter-defibrillator: The importance of the SMART pass algorithm.
    Rubio Campal JM; Benezet-Mazuecos J; Sánchez-Borque P; Blanco ÁM; Crosa J; Arias MA
    J Electrocardiol; 2018; 51(6):941-944. PubMed ID: 30497752
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Inappropriate shock for myopotential over-sensing in a patient with subcutaneous ICD.
    Corzani A; Ziacchi M; Biffi M; Diemberger I; Martignani C; Boriani G
    Indian Heart J; 2015; 67(1):56-9. PubMed ID: 25820052
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Prospective randomized multicenter trial of empirical antitachycardia pacing versus shocks for spontaneous rapid ventricular tachycardia in patients with implantable cardioverter-defibrillators: Pacing Fast Ventricular Tachycardia Reduces Shock Therapies (PainFREE Rx II) trial results.
    Wathen MS; DeGroot PJ; Sweeney MO; Stark AJ; Otterness MF; Adkisson WO; Canby RC; Khalighi K; Machado C; Rubenstein DS; Volosin KJ;
    Circulation; 2004 Oct; 110(17):2591-6. PubMed ID: 15492306
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Subcutaneous Implantable Cardioverter Defibrillator Lead Repositioning for Preventing Inappropriate Shocks Due to Myopotential Oversensing in a Post-Fulminant Myocarditis Patient.
    Sasaki T; Nakamura K; Naito S
    Int Heart J; 2019 Mar; 60(2):466-469. PubMed ID: 30745542
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.