These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
262 related articles for article (PubMed ID: 31899806)
1. Comprehensive radiation and imaging isocenter verification using NIPAM kV-CBCT dosimetry. Pant K; Umeh C; Oldham M; Floyd S; Giles W; Adamson J Med Phys; 2020 Mar; 47(3):927-936. PubMed ID: 31899806 [TBL] [Abstract][Full Text] [Related]
2. Technical Notes: Robustness of three-dimensional treatment and imaging isocenter testing using a new gel dosimeter and kilovoltage CBCT. Oshika R; Tachibana H; Seki K; Tachibana R; Moriya S; Sakae T J Appl Clin Med Phys; 2024 Sep; 25(9):e14439. PubMed ID: 39031633 [TBL] [Abstract][Full Text] [Related]
3. Efficient quality assurance method with automated data acquisition of a single phantom setup to determine radiation and imaging isocenter congruence. Kang H; Patel R; Roeske JC J Appl Clin Med Phys; 2019 Oct; 20(10):127-133. PubMed ID: 31535781 [TBL] [Abstract][Full Text] [Related]
4. A novel phantom and procedure providing submillimeter accuracy in daily QA tests of accelerators used for stereotactic radiosurgery*. Brezovich IA; Popple RA; Duan J; Shen S; Wu X; Benhabib S; Huang M; Cardan RA J Appl Clin Med Phys; 2016 Jul; 17(4):246-253. PubMed ID: 27455506 [TBL] [Abstract][Full Text] [Related]
5. Delivered Dose Distribution Visualized Directly With Onboard kV-CBCT: Proof of Principle. Adamson J; Carroll J; Trager M; Yoon SW; Kodra J; Maynard E; Hilts M; Oldham M; Jirasek A Int J Radiat Oncol Biol Phys; 2019 Apr; 103(5):1271-1279. PubMed ID: 30578910 [TBL] [Abstract][Full Text] [Related]
6. A novel verification method using a plastic scintillator imagining system for assessment of gantry sag in radiotherapy. Tsuneda M; Nishio T; Saito A; Tanaka S; Suzuki T; Kawahara D; Matsushita K; Nishio A; Ozawa S; Karasawa K; Nagata Y Med Phys; 2018 Jun; 45(6):2411-2424. PubMed ID: 29663431 [TBL] [Abstract][Full Text] [Related]
7. A positioning QA procedure for 2D/2D (kV/MV) and 3D/3D (CT/CBCT) image matching for radiotherapy patient setup. Guan H; Hammoud R; Yin FF J Appl Clin Med Phys; 2009 Oct; 10(4):273-280. PubMed ID: 19918223 [TBL] [Abstract][Full Text] [Related]
8. Dosimetric and geometric characteristics of a small animal image-guided irradiator using 3D dosimetry/optical CT scanner. Na YH; Wang YF; Black PJ; Velten C; Qian X; Lin SC; Adamovics J; Wuu CS Med Phys; 2018 Jul; 45(7):3330-3339. PubMed ID: 29746014 [TBL] [Abstract][Full Text] [Related]
9. Estimation of CT cone-beam geometry using a novel method insensitive to phantom fabrication inaccuracy: implications for isocenter localization accuracy. Ford JC; Zheng D; Williamson JF Med Phys; 2011 Jun; 38(6):2829-40. PubMed ID: 21815358 [TBL] [Abstract][Full Text] [Related]
10. Technical note: Comprehensive evaluations of gantry and couch rotation isocentricities for implementing proton stereotactic radiosurgery. Shen J; Robertson DG; Bues M; Shipulin K; Liu W; Stoker J; Ashman JB; Lara P; Keole SR; Wong W; Vora SA Med Phys; 2023 Jun; 50(6):3359-3367. PubMed ID: 36959772 [TBL] [Abstract][Full Text] [Related]
11. Off-iso Winston-Lutz test on seven linear accelerators. Gao J; Anand D J Appl Clin Med Phys; 2024 Oct; 25(10):e14470. PubMed ID: 39042435 [TBL] [Abstract][Full Text] [Related]
12. A quality assurance procedure to evaluate cone-beam CT image center congruence with the radiation isocenter of a linear accelerator. Du W; Yang JN; Chang EL; Luo D; McAleer MF; Shiu A; Martel MK J Appl Clin Med Phys; 2010 Jul; 11(4):3297. PubMed ID: 21081890 [TBL] [Abstract][Full Text] [Related]
13. SU-E-T-133: Isocenter Measurements with the Winston-Lutz Test: Impact on Treatment Planning. Templeton A; Chu J; Turian J Med Phys; 2012 Jun; 39(6Part11):3733-3734. PubMed ID: 28517166 [TBL] [Abstract][Full Text] [Related]
14. Investigating the accuracy of microstereotactic-body-radiotherapy utilizing anatomically accurate 3D printed rodent-morphic dosimeters. Bache ST; Juang T; Belley MD; Koontz BF; Adamovics J; Yoshizumi TT; Kirsch DG; Oldham M Med Phys; 2015 Feb; 42(2):846-55. PubMed ID: 25652497 [TBL] [Abstract][Full Text] [Related]
15. Cone-beam CT dosimetry for the positional variation in isocenter: a Monte Carlo study. Chow JC Med Phys; 2009 Aug; 36(8):3512-20. PubMed ID: 19746785 [TBL] [Abstract][Full Text] [Related]
16. Mobile C-arm cone-beam CT for guidance of spine surgery: image quality, radiation dose, and integration with interventional guidance. Schafer S; Nithiananthan S; Mirota DJ; Uneri A; Stayman JW; Zbijewski W; Schmidgunst C; Kleinszig G; Khanna AJ; Siewerdsena JH Med Phys; 2011 Aug; 38(8):4563-74. PubMed ID: 21928628 [TBL] [Abstract][Full Text] [Related]
17. Evaluation of the Machine Performance Check application for TrueBeam Linac. Clivio A; Vanetti E; Rose S; Nicolini G; Belosi MF; Cozzi L; Baltes C; Fogliata A Radiat Oncol; 2015 Apr; 10():97. PubMed ID: 25896341 [TBL] [Abstract][Full Text] [Related]
18. Feasibility of virtual starshot analysis providing submillimeter radiation isocenter accuracy: A long-term multi-institutional analysis. Akino Y; Fujiwara M; Mizuno H; Shiomi H; Kaneko A; Isohashi F; Seo Y; Suzuki O; Otani K; Tamari K; Ogawa K J Appl Clin Med Phys; 2019 Oct; 20(10):74-83. PubMed ID: 31502408 [TBL] [Abstract][Full Text] [Related]
19. Gantry and isocenter displacements of a linear accelerator caused by an add-on micromultileaf collimator. Riis HL; Zimmermann SJ; Hjelm-Hansen M Med Phys; 2013 Mar; 40(3):031707. PubMed ID: 23464302 [TBL] [Abstract][Full Text] [Related]
20. Intraoperative cone-beam CT for guidance of head and neck surgery: Assessment of dose and image quality using a C-arm prototype. Daly MJ; Siewerdsen JH; Moseley DJ; Jaffray DA; Irish JC Med Phys; 2006 Oct; 33(10):3767-80. PubMed ID: 17089842 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]