These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

136 related articles for article (PubMed ID: 31903758)

  • 1. Point-of-Care Assessment of Hemostasis with a Love-Mode Surface Acoustic Wave Sensor.
    Chen X; Wang M; Zhao G
    ACS Sens; 2020 Jan; 5(1):282-291. PubMed ID: 31903758
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Micro-electromechanical film bulk acoustic sensor for plasma and whole blood coagulation monitoring.
    Chen D; Song S; Ma J; Zhang Z; Wang P; Liu W; Guo Q
    Biosens Bioelectron; 2017 May; 91():465-471. PubMed ID: 28068607
    [TBL] [Abstract][Full Text] [Related]  

  • 3. ZnO Film Bulk Acoustic Resonator for the Kinetics Study of Human Blood Coagulation.
    Chen D; Zhang Z; Ma J; Wang W
    Sensors (Basel); 2017 May; 17(5):. PubMed ID: 28467374
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Shear Mode Bulk Acoustic Viscosity Sensor for Blood Coagulation Monitoring in Oral Anticoagulant Therapy.
    Song S; Chen D; Wang H; Guo Q; Yu W
    J Nanosci Nanotechnol; 2018 Dec; 18(12):8099-8104. PubMed ID: 30189925
    [TBL] [Abstract][Full Text] [Related]  

  • 5. ClotChip: A Microfluidic Dielectric Sensor for Point-of-Care Assessment of Hemostasis.
    Maji D; Suster MA; Kucukal E; Sekhon UDS; Gupta AS; Gurkan UA; Stavrou EX; Mohseni P
    IEEE Trans Biomed Circuits Syst; 2017 Dec; 11(6):1459-1469. PubMed ID: 28920906
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Temperature Monitorable Kinetics Study of Human Blood Coagulation by Utilizing a Dual-Mode AlN-Based Acoustic Wave Resonator.
    Zhang F; Wang X; Chen C; Zhou H; Yang J; Bai L; Xu Y; Cheng Y; Zhang S; Mu X
    IEEE Trans Ultrason Ferroelectr Freq Control; 2020 Jan; 67(1):131-135. PubMed ID: 31494547
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A Miniaturized Hemoretractometer for Blood Clot Retraction Testing.
    Li Z; Li X; McCracken B; Shao Y; Ward K; Fu J
    Small; 2016 Aug; 12(29):3926-34. PubMed ID: 27248117
    [TBL] [Abstract][Full Text] [Related]  

  • 8. First report of the point-of-care TEG: A technical validation study of the TEG-6S system.
    Gurbel PA; Bliden KP; Tantry US; Monroe AL; Muresan AA; Brunner NE; Lopez-Espina CG; Delmenico PR; Cohen E; Raviv G; Haugen DL; Ereth MH
    Platelets; 2016 Nov; 27(7):642-649. PubMed ID: 27809712
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Stability enhanced, repeatability improved Parylene-C passivated on QCM sensor for aPTT measurement.
    Yang Y; Zhang W; Guo Z; Zhang Z; Zhu H; Yan R; Zhou L
    Biosens Bioelectron; 2017 Dec; 98():41-46. PubMed ID: 28649023
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Viscoelastic point-of-care testing to assist with the diagnosis, management and monitoring of haemostasis: a systematic review and cost-effectiveness analysis.
    Whiting P; Al M; Westwood M; Ramos IC; Ryder S; Armstrong N; Misso K; Ross J; Severens J; Kleijnen J
    Health Technol Assess; 2015 Jul; 19(58):1-228, v-vi. PubMed ID: 26215747
    [TBL] [Abstract][Full Text] [Related]  

  • 11. QCM-D providing new horizon in the domain of sensitivity range and information for haemostasis of human plasma.
    Hussain M; Northoff H; Gehring FK
    Biosens Bioelectron; 2015 Apr; 66():579-84. PubMed ID: 25530537
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Perioperative monitoring of primary and secondary hemostasis in coronary artery bypass grafting.
    Hertfelder HJ; Bös M; Weber D; Winkler K; Hanfland P; Preusse CJ
    Semin Thromb Hemost; 2005; 31(4):426-40. PubMed ID: 16149021
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Simultaneous multiparameter whole blood hemostasis assessment using a carbon nanotube-paper composite capacitance sensor.
    Sekar PK; Liang XM; Kahng SJ; Shu Z; Dichiara AB; Chung JH; Wu Y; Gao D
    Biosens Bioelectron; 2022 Feb; 197():113786. PubMed ID: 34801797
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Assessment of Hemostasis after Plasma Exchange Using Rotational Thrombelastometry (ROTEM).
    Thölking G; Mesters R; Dittrich R; Pavenstädt H; Kümpers P; Reuter S
    PLoS One; 2015; 10(6):e0130402. PubMed ID: 26121484
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Investigation of prothrombin time in human whole-blood samples with a quartz crystal biosensor.
    Müller L; Sinn S; Drechsel H; Ziegler C; Wendel HP; Northoff H; Gehring FK
    Anal Chem; 2010 Jan; 82(2):658-63. PubMed ID: 20000697
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Quartz crystal microbalance-with dissipation monitoring (QCM-D) for real time measurements of blood coagulation density and immune complement activation on artificial surfaces.
    Andersson M; Andersson J; Sellborn A; Berglin M; Nilsson B; Elwing H
    Biosens Bioelectron; 2005 Jul; 21(1):79-86. PubMed ID: 15967354
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation for effects of severe acidosis on hemostasis in trauma patients using thrombelastography analyzer.
    Lv X; Mao Y; Qin Z
    Am J Emerg Med; 2018 Aug; 36(8):1332-1340. PubMed ID: 29276028
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Shear Mode Bulk Acoustic Resonator Based on Inclined
    Song S; Chen D; Wang H; Li C; Wang W; Yu W; Wang Y; Guo Q
    Micromachines (Basel); 2018 Sep; 9(10):. PubMed ID: 30424434
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comprehensive Coagulation Profiling at the Point-of-Care Using a Novel Laser-Based Approach.
    Nadkarni SK
    Semin Thromb Hemost; 2019 Apr; 45(3):264-274. PubMed ID: 30887486
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Monitoring of blood coagulation in perioperative care].
    Ishii H
    Masui; 2012 Jan; 61(1):47-56. PubMed ID: 22338860
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.