These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 3190563)

  • 1. Stapedius reflex threshold in cochlear implant patients.
    Stephan K; Welzl-Müller K; Stiglbrunner H
    Audiology; 1988; 27(4):227-33. PubMed ID: 3190563
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Dynamic range of the contralateral stapedius reflex in cochlear implant patients.
    Stephan K; Welzl-Müller K; Stiglbrunner H
    Scand Audiol; 1990; 19(2):111-5. PubMed ID: 2371534
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Correlation between electrically-induced stapedius reflex and discomfort threshold in cochlear implant patients].
    Gattaz G; Battmer RD; Lehnhardt E; Gnadeberg D
    HNO; 1992 Dec; 40(12):480-3. PubMed ID: 1493968
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Acoustic reflex in patients with cochlear implants (analog stimulation).
    Stephan K; Welzl-Müller K; Stiglbrunner H
    Am J Otol; 1991; 12 Suppl():48-51. PubMed ID: 2069188
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Prediction of dynamic range from stapedius reflex in cochlear implant patients.
    Jerger J; Oliver TA; Chmiel RA
    Ear Hear; 1988 Feb; 9(1):4-8. PubMed ID: 3342943
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Stapedius reflex growth function in cochlear implant patients.
    Stephan K; Welzl-Müller K; Stiglbrunner H
    Audiology; 1990; 29(1):46-54. PubMed ID: 2310353
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Stapedius reflex in patients with an inner ear prosthesis.
    Stephan K; Welzl-Müller K
    Int J Artif Organs; 1992 Jul; 15(7):436-9. PubMed ID: 1516996
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of stimulus duration on stapedius reflex threshold in electrical stimulation via cochlear implant.
    Stephan K; Welzl-Müller K
    Audiology; 1994; 33(3):143-51. PubMed ID: 8042935
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of Probe-Tone Frequency on Ipsilateral and Contralateral Electrical Stapedius Reflex Measurement in Children With Cochlear Implants.
    Carranco Hernandez L; Cristerna Sánchez L; Camacho Olivares M; Rodríguez C; Finley CC; Saoji AA
    Ear Hear; 2019; 40(3):732-740. PubMed ID: 30234691
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Contralateral electrically evoked reflex of the musculus stapedius in patients with cochlear implant].
    Potalova LA
    Vestn Otorinolaringol; 2003; (6):38-40. PubMed ID: 14671578
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Intraoperative recordings of electromyogenic responses from the human stapedius muscle.
    Zarowski A; Fuentes MC; Schaudel D; Leblans M; De Coninck L; Theunen T; Vermeiren A; Verschoren L; van Dinther J; Offeciers EF
    Hear Res; 2021 Sep; 408():108290. PubMed ID: 34233241
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Use of stapedius reflex in cochlear implant of congenitally deaf children.
    Ura M; Owa T; Nong D; Fusato N; Noda Y
    Adv Otorhinolaryngol; 2000; 57():165-7. PubMed ID: 11892137
    [No Abstract]   [Full Text] [Related]  

  • 13. Post-operative stapedius reflex tests with simultaneous loudness scaling in patients supplied with cochlear implants.
    Stephan K; Welzl-Müller K
    Audiology; 2000; 39(1):13-8. PubMed ID: 10749066
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effect of Number of Electrodes Used to Elicit Electrical Stapedius Reflex Thresholds in Cochlear Implants.
    Charroó LE; Bermejo S; Paz Cordovez AS; Rodríguez C; Finley CC; Saoji AA
    Audiol Neurootol; 2021; 26(3):164-172. PubMed ID: 33434909
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [The human stapedius reflex by ipsilateral electrical stimulation of the auditory meatal skin (author's transl)].
    Ono J; Nagel D; Pfalz R
    HNO; 1980 Mar; 28(3):104-7. PubMed ID: 7451253
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The Value of Electrically Evoked Stapedius Reflex in Determining the Maximum Comfort Level of a Cochlear Implant.
    de Andrade KCL; Muniz LF; Menezes PL; Neto SDSC; Carnaúba ATL; Leal MC
    J Am Acad Audiol; 2018 Apr; 29(4):292-299. PubMed ID: 29664723
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Effect of anesthesia on the intraoperative elicited stapedius reflex].
    Gnadeberg D; Battmer RD; Lüllwitz E; Laszig R; Dybus U; Lenarz T
    Laryngorhinootologie; 1994 Mar; 73(3):132-5. PubMed ID: 8172632
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Electrically elicited stapedius reflex in cochlear implant patients.
    Battmer RD; Laszig R; Lehnhardt E
    Ear Hear; 1990 Oct; 11(5):370-4. PubMed ID: 2262087
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Influence of EEG monitoring on intraoperative stapedius reflex threshold values in cochlear implantation in children.
    Schultz B; Beger FA; Weber BP; Niclaus O; Lüllwitz E; Grouven U; Schultz A
    Paediatr Anaesth; 2003 Nov; 13(9):790-6. PubMed ID: 14617120
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The Relationship between Electrical Stapedius Reflex Thresholds and Behaviorally Most Comfortable Levels in Experienced Cochlear Implant Users.
    Çiprut A; Adıgül Ç
    J Int Adv Otol; 2020 Apr; 16(1):8-12. PubMed ID: 31287433
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.