These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

208 related articles for article (PubMed ID: 31910084)

  • 1. Assessment of time to completion, number of errors, and knot-holding capacity of square knots and Aberdeen knots tied by veterinary students and student perceptions of knot security and knot-tying difficulty.
    Upchurch DA; Wang Y; Chen S; Roccabianca S; Roush JK
    J Am Vet Med Assoc; 2020 Jan; 256(2):230-238. PubMed ID: 31910084
    [TBL] [Abstract][Full Text] [Related]  

  • 2. In Vitro Evaluation of the Aberdeen Knot for Continuous Suture Patterns with Large Gauge Suture.
    Gillen AM; Munsterman AS; Farag R; Coleridge MO; Reid Hanson R
    Vet Surg; 2016 Oct; 45(7):955-961. PubMed ID: 27604910
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of fluid media on the mechanical properties of continuous pattern-ending surgeon's, square, and Aberdeen knots in vitro.
    Coleridge M; Gillen AM; Farag R; Hanson RR; Munsterman AS
    Vet Surg; 2017 Feb; 46(2):306-315. PubMed ID: 28146293
    [TBL] [Abstract][Full Text] [Related]  

  • 4. In vitro evaluation of the modified forwarder knot used to end a continuous suture pattern in large-gauge suture.
    Gillen A; Munsterman A; Barrett E; Caston S; Kersh K; Tatarniuk D; Swor T; Hanson RR
    Vet Surg; 2020 Dec; 49(8):1555-1562. PubMed ID: 32959894
    [TBL] [Abstract][Full Text] [Related]  

  • 5. In Vitro Evaluation of the Size, Knot Holding Capacity, and Knot Security of the Forwarder Knot Compared to Square and Surgeon's Knots Using Large Gauge Suture.
    Gillen AM; Munsterman AS; Hanson RR
    Vet Surg; 2016 Nov; 45(8):1034-1040. PubMed ID: 27685840
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of volume, security, and biomechanical strength of square and Aberdeen termination knots tied with 4-0 polyglyconate and used for termination of intradermal closures in canine cadavers.
    Regier PJ; Smeak DD; Coleman K; McGilvray KC
    J Am Vet Med Assoc; 2015 Aug; 247(3):260-6. PubMed ID: 26176725
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Arthroscopic knots: determining the optimal balance of loop security and knot security.
    Lo IK; Burkhart SS; Chan KC; Athanasiou K
    Arthroscopy; 2004 May; 20(5):489-502. PubMed ID: 15122139
    [TBL] [Abstract][Full Text] [Related]  

  • 8. In vitro evaluation of square and surgeon's knots in large gauge suture.
    Gillen AM; Munsterman AS; Farag R; Coleridge MO; Hanson RR
    Vet Surg; 2017 Feb; 46(2):297-305. PubMed ID: 28146289
    [TBL] [Abstract][Full Text] [Related]  

  • 9. In vitro holding security of four friction knots of monofilament or multifilament suture used as a first throw for vascular ligation.
    Tremolada G; Hazenfield KM; Smeak DD
    Am J Vet Res; 2020 Oct; 81(10):821-826. PubMed ID: 32969726
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Assessment of surgical trainees' quality of knot-tying.
    Ching SS; Mok CW; Koh YX; Tan SM; Tan YK
    J Surg Educ; 2013; 70(1):48-54. PubMed ID: 23337670
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of knot-tying proficiency and knot characteristics for square and reversing half hitch alternating-post surgical knots in a simulated deep body cavity among notice medical students.
    Wu V; Yeung C; Sykes EA; Zevin B
    Can J Surg; 2018 Dec; 61(6):385-391. PubMed ID: 30265640
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Knot security and tensile strength of suture materials.
    Marturello DM; McFadden MS; Bennett RA; Ragetly GR; Horn G
    Vet Surg; 2014 Jan; 43(1):73-9. PubMed ID: 24383708
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Security of knots tied with ethibond, fiberwire, orthocord, or ultrabraid.
    Ilahi OA; Younas SA; Ho DM; Noble PC
    Am J Sports Med; 2008 Dec; 36(12):2407-14. PubMed ID: 18827068
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Tensile strength of surgical knots in abdominal wound closure.
    Fong ED; Bartlett AS; Malak S; Anderson IA
    ANZ J Surg; 2008 Mar; 78(3):164-6. PubMed ID: 18269480
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The effect of number of throws on knot security with nonidentical sliding knots.
    Ivy JJ; Unger JB; Hurt J; Mukherjee D
    Am J Obstet Gynecol; 2004 Nov; 191(5):1618-20. PubMed ID: 15547532
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Differences of tensile strength in knot tying technique between orthopaedic surgical instructors and trainees.
    Harato K; Yagi M; Kaneda K; Iwama Y; Masuda A; Kaneko Y; Oya A; Matsumura N; Suzuki T; Nakayama R; Kobayashi S
    BMC Surg; 2021 Feb; 21(1):75. PubMed ID: 33549063
    [TBL] [Abstract][Full Text] [Related]  

  • 17. In vitro security of 3 surgical knots placed by novice veterinary students.
    Shaver SL; Yamada N; Hofmeister EH
    Vet Surg; 2019 Feb; 48(2):209-215. PubMed ID: 30570156
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Operating room fatigue: is your twentieth surgical knot as strong as your first?
    Muffly TM; Espaillat-Rijo LM; Edwards AM; Horton A
    J Surg Educ; 2012; 69(2):215-7. PubMed ID: 22365868
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Real-time objective assessment of knot quality with a portable tensiometer is superior to execution time for assessment of laparoscopic knot-tying performance.
    Ritter EM; McClusky DA; Gallagher AG; Smith CD
    Surg Innov; 2005 Sep; 12(3):233-7. PubMed ID: 16224644
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A secure Aberdeen knot: in vitro assessment of knot security in plasma and fat.
    Schaaf O; Glyde M; Day RE
    J Small Anim Pract; 2009 Aug; 50(8):415-21. PubMed ID: 19689669
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.