790 related articles for article (PubMed ID: 31925465)
1. A novel approach to SBRT patient quality assurance using EPID-based real-time transit dosimetry : A step to QA with in vivo EPID dosimetry.
Moustakis C; Ebrahimi Tazehmahalleh F; Elsayad K; Fezeu F; Scobioala S
Strahlenther Onkol; 2020 Feb; 196(2):182-192. PubMed ID: 31925465
[TBL] [Abstract][Full Text] [Related]
2. An in vivo dose verification method for SBRT-VMAT delivery using the EPID.
McCowan PM; Van Uytven E; Van Beek T; Asuni G; McCurdy BM
Med Phys; 2015 Dec; 42(12):6955-63. PubMed ID: 26632051
[TBL] [Abstract][Full Text] [Related]
3. Clinical experience with EPID dosimetry for prostate IMRT pre-treatment dose verification.
McDermott LN; Wendling M; van Asselen B; Stroom J; Sonke JJ; van Herk M; Mijnheer BJ
Med Phys; 2006 Oct; 33(10):3921-30. PubMed ID: 17089854
[TBL] [Abstract][Full Text] [Related]
4. EPID sensitivity to delivery errors for pre-treatment verification of lung SBRT VMAT plans.
Alharthi T; Arumugam S; Vial P; Holloway L; Thwaites D
Phys Med; 2019 Mar; 59():37-46. PubMed ID: 30928064
[TBL] [Abstract][Full Text] [Related]
5. In aqua vivo EPID dosimetry.
Wendling M; McDermott LN; Mans A; Olaciregui-Ruiz Í; Pecharromán-Gallego R; Sonke JJ; Stroom J; van Herk M; Mijnheer BJ
Med Phys; 2012 Jan; 39(1):367-77. PubMed ID: 22225306
[TBL] [Abstract][Full Text] [Related]
6. A novel approach to EPID-based 3D volumetric dosimetry for IMRT and VMAT QA.
Alhazmi A; Gianoli C; Neppl S; Martins J; Veloza S; Podesta M; Verhaegen F; Reiner M; Belka C; Parodi K
Phys Med Biol; 2018 May; 63(11):115002. PubMed ID: 29714714
[TBL] [Abstract][Full Text] [Related]
7. Transit and non-transit 3D EPID dosimetry versus detector arrays for patient specific QA.
Olaciregui-Ruiz I; Vivas-Maiques B; Kaas J; Perik T; Wittkamper F; Mijnheer B; Mans A
J Appl Clin Med Phys; 2019 Jun; 20(6):79-90. PubMed ID: 31083776
[TBL] [Abstract][Full Text] [Related]
8. Sensitivity study of an automated system for daily patient QA using EPID exit dose images.
Zhuang AH; Olch AJ
J Appl Clin Med Phys; 2018 May; 19(3):114-124. PubMed ID: 29508529
[TBL] [Abstract][Full Text] [Related]
9. Development of a quasi-3D dosimeter using radiochromic plastic for patient-specific quality assurance.
Cho JD; Jin H; Jung S; Son J; Choi CH; Park JM; Kim JS; Kim JI
Med Phys; 2023 Oct; 50(10):6624-6636. PubMed ID: 37408321
[TBL] [Abstract][Full Text] [Related]
10. Validation of a method for in vivo 3D dose reconstruction for IMRT and VMAT treatments using on-treatment EPID images and a model-based forward-calculation algorithm.
Van Uytven E; Van Beek T; McCowan PM; Chytyk-Praznik K; Greer PB; McCurdy BM
Med Phys; 2015 Dec; 42(12):6945-54. PubMed ID: 26632050
[TBL] [Abstract][Full Text] [Related]
11. Toward real-time verification for MLC tracking treatments using time-resolved EPID imaging.
Zwan BJ; Caillet V; Booth JT; Colvill E; Fuangrod T; O'Brien R; Briggs A; O'Connor DJ; Keall PJ; Greer PB
Med Phys; 2021 Mar; 48(3):953-964. PubMed ID: 33354787
[TBL] [Abstract][Full Text] [Related]
12. Quantitative evaluation of 3D dosimetry for stereotactic volumetric-modulated arc delivery using COMPASS.
Vikraman S; Manigandan D; Karrthick KP; Sambasivaselli R; Senniandavar V; Ramu M; Rajesh T; Lutz M; Muthukumaran M; Karthikeyan N; Tejinder K
J Appl Clin Med Phys; 2014 Jan; 16(1):5128. PubMed ID: 25679152
[TBL] [Abstract][Full Text] [Related]
13. Practical approach for pretreatment verification of IMRT with flattening filter free(FFF) beams using Varian Portal Dosimetry.
Min S; Choi YE; Kwak J; Cho B
J Appl Clin Med Phys; 2014 Jan; 16(1):4934. PubMed ID: 25679149
[TBL] [Abstract][Full Text] [Related]
14. Epid-based in vivo dose verification for lung stereotactic treatments delivered with multiple breath-hold segmented volumetric modulated arc therapy.
Cilla S; Ianiro A; Craus M; Viola P; Deodato F; Macchia G; Buwenge M; Morganti AG; Valentini V; Piermattei A
J Appl Clin Med Phys; 2019 Mar; 20(3):37-44. PubMed ID: 30790439
[TBL] [Abstract][Full Text] [Related]
15. Deep learning-based tools to distinguish plan-specific from generic deviations in EPID-based in vivo dosimetry.
Olaciregui-Ruiz I; Simões R; Jan-Jakob S
Med Phys; 2024 Feb; 51(2):854-869. PubMed ID: 38112213
[TBL] [Abstract][Full Text] [Related]
16. Pixel response-based EPID dosimetry for patient specific QA.
Han B; Ding A; Lu M; Xing L
J Appl Clin Med Phys; 2017 Jan; 18(1):9-17. PubMed ID: 28291939
[TBL] [Abstract][Full Text] [Related]
17. A novel method for sub-arc VMAT dose delivery verification based on portal dosimetry with an EPID.
Cools RAM; Dirkx MLP; Heijmen BJM
Med Phys; 2017 Nov; 44(11):5556-5562. PubMed ID: 28815696
[TBL] [Abstract][Full Text] [Related]
18. Comparison of forward- and back-projection in vivo EPID dosimetry for VMAT treatment of the prostate.
Bedford JL; Hanson IM; Hansen VN
Phys Med Biol; 2018 Jan; 63(2):025008. PubMed ID: 29165319
[TBL] [Abstract][Full Text] [Related]
19. A Swiss cheese error detection method for real-time EPID-based quality assurance and error prevention.
Passarge M; Fix MK; Manser P; Stampanoni MF; Siebers JV
Med Phys; 2017 Apr; 44(4):1212-1223. PubMed ID: 28134989
[TBL] [Abstract][Full Text] [Related]
20. EPID-based 3D dosimetry for pre-treatment FFF VMAT stereotactic body radiotherapy plan verification using dosimetry Check
Chendi A; Botti A; Orlandi M; Sghedoni R; Iori M; Cagni E
Phys Med; 2021 Jan; 81():227-236. PubMed ID: 33485140
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]