264 related articles for article (PubMed ID: 31932928)
21. Feasibility and safety of a fully covered self-expandable metal stent with antimigration properties for EUS-guided pancreatic duct drainage: early and midterm outcomes (with video).
Oh D; Park DH; Cho MK; Nam K; Song TJ; Lee SS; Seo DW; Lee SK; Kim MH
Gastrointest Endosc; 2016 Feb; 83(2):366-73.e2. PubMed ID: 26324387
[TBL] [Abstract][Full Text] [Related]
22. EUS-guided hepaticogastrostomy with a fully covered metal stent as the biliary diversion technique for an occluded biliary metal stent after a failed ERCP (with videos).
Park DH; Song TJ; Eum J; Moon SH; Lee SS; Seo DW; Lee SK; Kim MH
Gastrointest Endosc; 2010 Feb; 71(2):413-9. PubMed ID: 20152319
[TBL] [Abstract][Full Text] [Related]
23. Multicenter prospective evaluation study of endoscopic ultrasound-guided hepaticogastrostomy combined with antegrade stenting (with video).
Ogura T; Kitano M; Takenaka M; Okuda A; Minaga K; Yamao K; Yamashita Y; Hatamaru K; Noguchi C; Gotoh Y; Kuroda T; Yokota T; Nishikiori H; Sagami R; Higuchi K; Chiba Y
Dig Endosc; 2018 Mar; 30(2):252-259. PubMed ID: 29055054
[TBL] [Abstract][Full Text] [Related]
24. Single-balloon enteroscopy assisted successful removal of a migrated covered self-expandable metal stent for hepaticojejunostomy anastomotic stenosis.
Toyonaga H; Hayashi T; Katanuma A
Dig Endosc; 2021 Mar; 33(3):e36-e38. PubMed ID: 33377236
[No Abstract] [Full Text] [Related]
25. Efficacy of the 6-mm fully covered self-expandable metal stent during endoscopic ultrasound-guided hepaticogastrostomy as a primary biliary drainage for the cases estimated difficult endoscopic retrograde cholangiopancreatography: A prospective clinical study.
Okuno N; Hara K; Mizuno N; Kuwahara T; Iwaya H; Ito A; Kuraoka N; Matsumoto S; Polmanee P; Niwa Y
J Gastroenterol Hepatol; 2018 Jul; 33(7):1413-1421. PubMed ID: 29424011
[TBL] [Abstract][Full Text] [Related]
26. A prospective group sequential study evaluating a new type of fully covered self-expandable metal stent for the treatment of benign biliary strictures (with video).
Poley JW; Cahen DL; Metselaar HJ; van Buuren HR; Kazemier G; van Eijck CH; Haringsma J; Kuipers EJ; Bruno MJ
Gastrointest Endosc; 2012 Apr; 75(4):783-9. PubMed ID: 22325806
[TBL] [Abstract][Full Text] [Related]
27. Pilot Study of Dumbbell-Type Covered Self-Expandable Metal Stent Deployment for Benign Pancreatic Duct Stricture (with Videos).
Yamada T; Ogura T; Okuda A; Imanishi M; Kamiyama R; Miyano A; Nishioka N; Higuchi K
J Gastrointest Surg; 2018 Dec; 22(12):2194-2200. PubMed ID: 30084065
[TBL] [Abstract][Full Text] [Related]
28. Temporary placement of a covered duodenal stent can avoid riskier anterograde biliary drainage when ERCP for obstructive jaundice fails due to duodenal invasion.
Goutorbe F; Rouquette O; Mulliez A; Scanzi J; Goutte M; Dapoigny M; Abergel A; Poincloux L
Surg Endosc; 2017 Feb; 31(2):625-631. PubMed ID: 27324333
[TBL] [Abstract][Full Text] [Related]
29. Clinical evaluation of a novel drill dilator as the first-line tract dilation technique during EUS-guided biliary drainage by nonexpert hands (with videos).
Hattori N; Ogura T; Ueno S; Okuda A; Nishioka N; Miyano A; Yamamoto Y; Bessho K; Uba Y; Tomita M; Nakamura J; Nishikawa H
Gastrointest Endosc; 2023 Jun; 97(6):1153-1157. PubMed ID: 36773897
[TBL] [Abstract][Full Text] [Related]
30. Multicenter study on endoscopic ultrasound-guided expandable biliary metal stent placement: choice of access route, direction of stent insertion, and drainage route.
Dhir V; Artifon EL; Gupta K; Vila JJ; Maselli R; Frazao M; Maydeo A
Dig Endosc; 2014 May; 26(3):430-5. PubMed ID: 23941261
[TBL] [Abstract][Full Text] [Related]
31. Technical feasibility and safety of one-step deployment of EUS-guided hepaticogastrostomy using an 8-mm diameter metal stent with a fine-gauge stent delivery system (with video).
Ogura T; Ueno S; Okuda A; Nishioka N; Yamada M; Matsuno J; Ueshima K; Yamamoto Y; Higuchi K
Endosc Ultrasound; 2021; 10(5):355-360. PubMed ID: 34427190
[TBL] [Abstract][Full Text] [Related]
32. Endoscopic treatment of hepaticojejunostomy anastomotic strictures using fully-covered metal stents.
Sato T; Kogure H; Nakai Y; Kanai S; Ishigaki K; Hakuta R; Saito K; Saito T; Takahara N; Hamada T; Mizuno S; Yamada A; Isayama H; Koike K
Dig Endosc; 2021 Mar; 33(3):451-457. PubMed ID: 32559351
[TBL] [Abstract][Full Text] [Related]
33. Endoscopic ultrasound-guided antegrade biliary stenting for unresectable malignant biliary obstruction in patients with surgically altered anatomy: Single-center prospective pilot study.
Iwashita T; Yasuda I; Mukai T; Iwata K; Doi S; Uemura S; Mabuchi M; Okuno M; Shimizu M
Dig Endosc; 2017 May; 29(3):362-368. PubMed ID: 28066983
[TBL] [Abstract][Full Text] [Related]
34. Fully covered self-expanding metal stents for refractory anastomotic colorectal strictures.
Caruso A; Conigliaro R; Manta R; Manno M; Bertani H; Barbera C; Mirante VG; Frazzoni M
Surg Endosc; 2015 May; 29(5):1175-8. PubMed ID: 25149637
[TBL] [Abstract][Full Text] [Related]
35. A New Fully Covered Self-Expandable Metal Stent for the Treatment of Postsurgical Benign Biliary Strictures.
Wu J; Zhou DX; Wang TT; Gao DJ; Hu B
Dig Dis Sci; 2017 Sep; 62(9):2550-2557. PubMed ID: 28776138
[TBL] [Abstract][Full Text] [Related]
36. Efficacy of double-balloon enteroscopy-assisted endoscopic balloon dilatation combined with stent deployment for hepaticojejunostomy anastomotic stricture.
Tomoda T; Kato H; Ueki T; Ogawa T; Hirao K; Akimoto Y; Matsumoto K; Horiguchi S; Tsutsumi K; Okada H
Dig Endosc; 2022 Mar; 34(3):604-611. PubMed ID: 34324732
[TBL] [Abstract][Full Text] [Related]
37. One-step deployment for EUS-guided gallbladder drainage using a novel fully covered metal stent (with video).
Ogura T; Ueno S; Okuda A; Nishioka N; Higuchi K
J Hepatobiliary Pancreat Sci; 2021 Feb; 28(2):e4-e5. PubMed ID: 33283470
[TBL] [Abstract][Full Text] [Related]
38. Novel drill dilator facilitates endoscopic ultrasound-guided hepaticogastrostomy.
Okuno N; Hara K; Haba S; Kuwahara T; Kuraishi Y; Yanaidani T; Ishikawa S; Yasuda T; Yamada M; Fukui T
Dig Endosc; 2023 Mar; 35(3):389-393. PubMed ID: 36170547
[TBL] [Abstract][Full Text] [Related]
39. Propensity score matching analysis for clinical impact of braided-type versus laser-cut-type covered self-expandable metal stents for endoscopic ultrasound-guided hepaticogastrostomy.
Tomita M; Ogura T; Hakoda A; Ueno S; Okuda A; Nishioka N; Yamamoto Y; Nishikawa H
Hepatobiliary Pancreat Dis Int; 2024 Apr; 23(2):181-185. PubMed ID: 37634988
[TBL] [Abstract][Full Text] [Related]
40. Endoscopic fully covered self-expandable metal stent and vacuum-assisted drainage to treat postoperative colorectal cancer anastomotic stenosis with fistula.
Deng S; Liu K; Gu J; Cao Y; Mao F; Xue Y; Jiang Z; Qin L; Wu K; Cai K
Surg Endosc; 2023 May; 37(5):3780-3788. PubMed ID: 36690896
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]