These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

176 related articles for article (PubMed ID: 31936657)

  • 21. Investigation of a CPG-array CdZnTe γ-ray imaging detector with single collecting electrodes readout.
    Ma Y; Xiao S; Yang G; Zhang L
    J Synchrotron Radiat; 2015 Nov; 22(6):1403-9. PubMed ID: 26524305
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Modeling the frequency-dependent detective quantum efficiency of photon-counting x-ray detectors.
    Stierstorfer K
    Med Phys; 2018 Jan; 45(1):156-166. PubMed ID: 29131361
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Tutorial on X-ray photon counting detector characterization.
    Ren L; Zheng B; Liu H
    J Xray Sci Technol; 2018; 26(1):1-28. PubMed ID: 29154310
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Experimental and simulation research on the screening effect of the pixelated CZT imaging detector.
    Li M; Zha G; Zhou B; Ma Y; Xiao S; Zhao M; Ding K; Zhou S
    Appl Radiat Isot; 2018 Jul; 137():91-101. PubMed ID: 29597105
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Photon counting multienergy x-ray imaging: effect of the characteristic x rays on detector performance.
    Shikhaliev PM; Fritz SG; Chapman JW
    Med Phys; 2009 Nov; 36(11):5107-19. PubMed ID: 19994521
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Theoretical investigation of the count rate capabilities of in-pixel amplifiers for photon counting arrays based on polycrystalline silicon TFTs.
    Liang AK; Koniczek M; Antonuk LE; El-Mohri Y; Zhao Q
    Med Phys; 2018 Oct; 45(10):4418-4429. PubMed ID: 30106180
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Count statistics of nonparalyzable photon-counting detectors with nonzero pulse length.
    Grönberg F; Danielsson M; Sjölin M
    Med Phys; 2018 Jun; ():. PubMed ID: 29939402
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Spatio-energetic cross-talk in photon counting detectors: N × N binning and sub-pixel masking.
    Taguchi K; Stierstorfer K; Polster C; Lee O; Kappler S
    Med Phys; 2018 Nov; 45(11):4822-4843. PubMed ID: 30136278
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Tilted angle CZT detector for photon counting/energy weighting x-ray and CT imaging.
    Shikhaliev PM
    Phys Med Biol; 2006 Sep; 51(17):4267-87. PubMed ID: 16912381
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A framework for performance characterization of energy-resolving photon-counting detectors.
    Persson M; Rajbhandary PL; Pelc NJ
    Med Phys; 2018 Nov; 45(11):4897-4915. PubMed ID: 30191571
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Progress in the Development of CdTe and CdZnTe Semiconductor Radiation Detectors for Astrophysical and Medical Applications.
    Sordo SD; Abbene L; Caroli E; Mancini AM; Zappettini A; Ubertini P
    Sensors (Basel); 2009; 9(5):3491-526. PubMed ID: 22412323
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Direct measurement of mammographic x-ray spectra using a CdZnTe detector.
    Matsumoto M; Yamamoto A; Honda I; Taniguchi A; Kanamori H
    Med Phys; 2000 Jul; 27(7):1490-502. PubMed ID: 10947252
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Room-temperature performance of 3 mm-thick cadmium-zinc-telluride pixel detectors with sub-millimetre pixelization.
    Buttacavoli A; Principato F; Gerardi G; Bettelli M; Sarzi Amadè N; Zappettini A; Seller P; Veale MC; Fox O; Sawhney K; Abbene L
    J Synchrotron Radiat; 2020 Sep; 27(Pt 5):1180-1189. PubMed ID: 32876592
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Spectral resolution and high-flux capability tradeoffs in CdTe detectors for clinical CT.
    Hsieh SS; Rajbhandary PL; Pelc NJ
    Med Phys; 2018 Apr; 45(4):1433-1443. PubMed ID: 29418004
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Characterization of energy response for photon-counting detectors using x-ray fluorescence.
    Ding H; Cho HM; Barber WC; Iwanczyk JS; Molloi S
    Med Phys; 2014 Dec; 41(12):121902. PubMed ID: 25471962
    [TBL] [Abstract][Full Text] [Related]  

  • 36. SemiSPECT: A Small-animal Imaging System Based on Eight CdZnTe Pixel Detectors.
    Peterson TE; Kim H; Crawford MJ; Gershman BM; Hunter WC; Barber HB; Furenlid LR; Wilson DW; Woolfenden JM; Barrett HH
    IEEE Nucl Sci Symp Conf Rec (1997); 2002; 3():1844-1847. PubMed ID: 26568674
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Design and study of a coplanar grid array CdZnTe detector for improved spatial resolution.
    Ma Y; Xiao S; Yang G; Zhang L
    Appl Radiat Isot; 2014 Dec; 94():314-318. PubMed ID: 25305523
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Photon counting computed tomography: concept and initial results.
    Shikhaliev PM; Xu T; Molloi S
    Med Phys; 2005 Feb; 32(2):427-36. PubMed ID: 15789589
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Role of the Metal-Semiconductor Interface in Halide Perovskite Devices for Radiation Photon Counting.
    Shrestha S; Tsai H; Yoho M; Ghosh D; Liu F; Lei Y; Tisdale J; Baldwin J; Xu S; Neukirch AJ; Tretiak S; Vo D; Nie W
    ACS Appl Mater Interfaces; 2020 Oct; 12(40):45533-45540. PubMed ID: 32886475
    [TBL] [Abstract][Full Text] [Related]  

  • 40. 3-D Spatial Resolution of 350
    Yin Y; Chen X; Wu H; Komarov S; Garson A; Li Q; Guo Q; Krawczynski H; Meng LJ; Tai YC
    IEEE Trans Nucl Sci; 2013 Feb; 60(1):9-15. PubMed ID: 28250476
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.