BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

442 related articles for article (PubMed ID: 31937063)

  • 1. [Comparison of keratometric measurements obtained by the Verion image guided system with the IOLMaster and the Pentacam before cataract extraction surgery].
    Wu J; Gao P; Fan JW; Li TT; Liu F
    Zhonghua Yan Ke Za Zhi; 2020 Jan; 56(1):47-52. PubMed ID: 31937063
    [No Abstract]   [Full Text] [Related]  

  • 2. Assessment of Corneal Keratometric and Astigmatism Measurements Using Verion System and Other Instruments in Cataract Patient.
    Fu Y; Yu X; Savini G; Huang J; Lian H; Song B; Wang Q; Zhao Y
    Curr Eye Res; 2018 Oct; 43(10):1205-1214. PubMed ID: 29890084
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Assessment of corneal curvature using verion optical imaging system: a comparative study.
    Lauschke JL; Lawless M; Sutton G; Roberts TV; Hodge C
    Clin Exp Ophthalmol; 2016 Jul; 44(5):369-76. PubMed ID: 27381574
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of keratometric measurements obtained by the Verion Image Guided System with optical biometry and auto-keratorefractometer.
    Asena L; Güngör SG; Akman A
    Int Ophthalmol; 2017 Apr; 37(2):391-399. PubMed ID: 27271763
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Comparison of corneal refractive power and astigmatism measured by the new anterior segment optical coherence tomographic device and Scheimpflug imaging device in age-related cataract patients].
    Gao YC; Jiang YF; Lin S; Tian F
    Zhonghua Yan Ke Za Zhi; 2021 Jan; 57(1):48-55. PubMed ID: 33412642
    [No Abstract]   [Full Text] [Related]  

  • 6. Comparison of Keratometry Obtained by a Swept Source OCT-Based Biometer with a Standard Optical Biometer and Scheimpflug Imaging.
    Asena L; Akman A; Güngör SG; Dursun Altınörs D
    Curr Eye Res; 2018 Jul; 43(7):882-888. PubMed ID: 29630418
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Influence factors of estimation errors for total corneal astigmatism using keratometric astigmatism in patients before cataract surgery.
    Zheng T; Chen Z; Lu Y
    J Cataract Refract Surg; 2016 Jan; 42(1):84-94. PubMed ID: 26948782
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of keratometric measurements between color light-emitting diode topography and Scheimpflug camera.
    Cui XH; Yoo YS; An Y; Joo CK
    BMC Ophthalmol; 2019 Apr; 19(1):98. PubMed ID: 31027491
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of the Astigmatic Power of Toric Intraocular Lenses Using Three Toric Calculators.
    Park HJ; Lee H; Woo YJ; Kim EK; Seo KY; Kim HY; Kim TI
    Yonsei Med J; 2015 Jul; 56(4):1097-105. PubMed ID: 26069135
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of the accuracy of four Pentacam corneal astigmatism values in non-toric pseudophakic eyes.
    Zheng T; Xu J; Lu Y
    Graefes Arch Clin Exp Ophthalmol; 2020 Apr; 258(4):795-803. PubMed ID: 31900645
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Validation of keratometric measurements obtained with an intraoperative image-guided system: intra-session repeatability and interchangeability with an optical biometer.
    Ruiz-Belda C; Rodrigo F; Piñero DP
    Clin Exp Optom; 2018 Mar; 101(2):200-205. PubMed ID: 29090488
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of corneal power obtained from VERION image-guided surgery system and four other devices.
    Lin HY; Chen HY; Fam HB; Chuang YJ; Yeoh R; Lin PJ
    Clin Ophthalmol; 2017; 11():1291-1299. PubMed ID: 28744097
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Posterior Corneal Characteristics of Cataract Patients with High Myopia.
    Jing Q; Tang Y; Qian D; Lu Y; Jiang Y
    PLoS One; 2016; 11(9):e0162012. PubMed ID: 27603713
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Prevalence of corneal astigmatism before cataract surgery.
    Mohammadi M; Naderan M; Pahlevani R; Jahanrad A
    Int Ophthalmol; 2016 Dec; 36(6):807-817. PubMed ID: 26909501
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparability of an image-guided system with other instruments in measuring corneal keratometry and astigmatism.
    Schultz M; Oberheide U; Kermani O
    J Cataract Refract Surg; 2016 Jun; 42(6):904-12. PubMed ID: 27373398
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Univariate and bivariate polar value analysis of corneal astigmatism measurements obtained with 6 instruments.
    Lee H; Chung JL; Kim EK; Sgrignoli B; Kim TI
    J Cataract Refract Surg; 2012 Sep; 38(9):1608-15. PubMed ID: 22795977
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of biometric measurements obtained by the Verion Image-Guided System versus the auto-refracto-keratometer.
    Velasco-Barona C; Cervantes-Coste G; Mendoza-Schuster E; Corredor-Ortega C; Casillas-Chavarín NL; Silva-Moreno A; Garza-León M; Gonzalez-Salinas R
    Int Ophthalmol; 2018 Jun; 38(3):951-957. PubMed ID: 28444525
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Characteristics and analysis of corneal astigmatism in age-related cataract patients over 50 years old].
    Pang YL; Yuan L; Cao XG; Hou XR; Bao YZ
    Zhonghua Yan Ke Za Zhi; 2020 May; 56(5):349-355. PubMed ID: 32450667
    [No Abstract]   [Full Text] [Related]  

  • 19. Repeatability and agreement of Scheimpflug-based and swept-source optical biometry measurements.
    Sel S; Stange J; Kaiser D; Kiraly L
    Cont Lens Anterior Eye; 2017 Oct; 40(5):318-322. PubMed ID: 28342729
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Agreement between Keratometric readings by VERION image guided System, Galilei G4 and Pentacam.
    Habib A; Khan MS; Ishaq M; Yaqub MA
    Pak J Med Sci; 2018; 34(3):740-743. PubMed ID: 30034450
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 23.