BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

197 related articles for article (PubMed ID: 31937136)

  • 21. Two-Year Outcomes in Patients With Severe Aortic Valve Stenosis Randomized to Transcatheter Versus Surgical Aortic Valve Replacement: The All-Comers Nordic Aortic Valve Intervention Randomized Clinical Trial.
    Søndergaard L; Steinbrüchel DA; Ihlemann N; Nissen H; Kjeldsen BJ; Petursson P; Ngo AT; Olsen NT; Chang Y; Franzen OW; Engstrøm T; Clemmensen P; Olsen PS; Thyregod HG
    Circ Cardiovasc Interv; 2016 Jun; 9(6):. PubMed ID: 27296202
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Clinical and hemodynamic results after direct transcatheter aortic valve replacement versus pre-implantation balloon aortic valvuloplasty: A case-matched analysis.
    Ferrera C; Nombela-Franco L; Garcia E; Jimenez-Quevedo P; Biagioni C; Gonzalo N; Nuñez-Gil I; Viana-Tejedor A; Salinas P; Alberto de Agustin J; Almeria C; Islas F; Perez de Isla L; Fernandez-Perez C; Escaned J; Fernández-Ortiz A; Macaya C
    Catheter Cardiovasc Interv; 2017 Nov; 90(5):809-816. PubMed ID: 27515377
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Left Ventricular Hypertrophy Does Not Affect 1-Year Clinical Outcomes in Patients Undergoing Transcatheter Aortic Valve Replacement.
    Varshney AS; Manandhar P; Vemulapalli S; Kirtane AJ; Mathew V; Shah B; Lowenstern A; Kosinski AS; Kaneko T; Thourani VH; Bhatt DL
    JACC Cardiovasc Interv; 2019 Feb; 12(4):373-382. PubMed ID: 30784643
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Computed Tomography-Based Indexed Aortic Annulus Size to Predict Prosthesis-Patient Mismatch.
    Head SJ; Reardon MJ; Deeb GM; Van Mieghem NM; Popma JJ; Gleason TG; Williams MR; Radhakrishnan S; Fremes S; Oh JK; Chang Y; Boulware MJ; Kappetein AP
    Circ Cardiovasc Interv; 2019 Apr; 12(4):e007396. PubMed ID: 30929507
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Outcomes of Redo Transcatheter Aortic Valve Replacement for the Treatment of Postprocedural and Late Occurrence of Paravalvular Regurgitation and Transcatheter Valve Failure.
    Barbanti M; Webb JG; Tamburino C; Van Mieghem NM; Makkar RR; Piazza N; Latib A; Sinning JM; Won-Keun K; Bleiziffer S; Bedogni F; Kapadia S; Tchetche D; Rodés-Cabau J; Fiorina C; Nombela-Franco L; De Marco F; de Jaegere PP; Chakravarty T; Vaquerizo B; Colombo A; Svensson L; Lange R; Nickenig G; Möllmann H; Walther T; Della Rosa F; Elhmidi Y; Dvir D; Brambilla N; Immè S; Sgroi C; Gulino S; Todaro D; Pilato G; Petronio AS; Tamburino C
    Circ Cardiovasc Interv; 2016 Sep; 9(9):. PubMed ID: 27578840
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Prognostic Relevance of Left Ventricular Myocardial Performance After Transcatheter Aortic Valve Replacement.
    Asami M; Pilgrim T; Lanz J; Heg D; Franzone A; Piccolo R; Langhammer B; Praz F; Räber L; Valgimigli M; Roost E; Windecker S; Stortecky S
    Circ Cardiovasc Interv; 2019 Jan; 12(1):e006612. PubMed ID: 30626203
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Mitral Regurgitation After Transcatheter Aortic Valve Replacement: Prognosis, Imaging Predictors, and Potential Management.
    Cortés C; Amat-Santos IJ; Nombela-Franco L; Muñoz-Garcia AJ; Gutiérrez-Ibanes E; De La Torre Hernandez JM; Córdoba-Soriano JG; Jimenez-Quevedo P; Hernández-García JM; Gonzalez-Mansilla A; Ruano J; Jimenez-Mazuecos J; Castrodeza J; Tobar J; Islas F; Revilla A; Puri R; Puerto A; Gómez I; Rodés-Cabau J; San Román JA
    JACC Cardiovasc Interv; 2016 Aug; 9(15):1603-14. PubMed ID: 27491611
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Outcomes Following Urgent/Emergent Transcatheter Aortic Valve Replacement: Insights From the STS/ACC TVT Registry.
    Kolte D; Khera S; Vemulapalli S; Dai D; Heo S; Goldsweig AM; Aronow HD; Elmariah S; Inglessis I; Palacios IF; Thourani VH; Sharaf BL; Gordon PC; Abbott JD
    JACC Cardiovasc Interv; 2018 Jun; 11(12):1175-1185. PubMed ID: 29929641
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Role of contractile reserve as a predictor of mortality in low-flow, low-gradient severe aortic stenosis following transcatheter aortic valve replacement.
    Buchanan KD; Rogers T; Steinvil A; Koifman E; Xu L; Torguson R; Okubagzi PG; Shults C; Pichard AD; Ben-Dor I; Satler LF; Waksman R; Asch FM
    Catheter Cardiovasc Interv; 2019 Mar; 93(4):707-712. PubMed ID: 30280469
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Intervention Versus Observation in Symptomatic Patients With Normal Flow Low Gradient Severe Aortic Stenosis.
    Zusman O; Pressman GS; Banai S; Finkelstein A; Topilsky Y
    JACC Cardiovasc Imaging; 2018 Sep; 11(9):1225-1232. PubMed ID: 29055632
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Incidence, Predictors, and Clinical Impact of Prosthesis-Patient Mismatch Following Transcatheter Aortic Valve Replacement in Asian Patients: The OCEAN-TAVI Registry.
    Miyasaka M; Tada N; Taguri M; Kato S; Enta Y; Otomo T; Hata M; Watanabe Y; Naganuma T; Araki M; Yamanaka F; Shirai S; Ueno H; Mizutani K; Tabata M; Higashimori A; Takagi K; Yamamoto M; Hayashida K;
    JACC Cardiovasc Interv; 2018 Apr; 11(8):771-780. PubMed ID: 29673509
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Durability and Clinical Outcomes of Transcatheter Aortic Valve Replacement for Failed Surgical Bioprostheses.
    Dauerman HL; Deeb GM; O'Hair DP; Waksman R; Yakubov SJ; Kleiman NS; Chetcuti SJ; Hermiller JB; Bajwa T; Khabbaz K; de Marchena E; Salerno T; Dries-Devlin JL; Li S; Popma JJ; Reardon MJ
    Circ Cardiovasc Interv; 2019 Oct; 12(10):e008155. PubMed ID: 31607151
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Echocardiographic determinants of LV functional improvement after transcatheter aortic valve replacement.
    Chen J; Nawaz N; Fox Z; Komlo C; Anwaruddin S; Desai N; Jagasia D; Herrmann HC; Han Y
    Catheter Cardiovasc Interv; 2016 May; 87(6):1164-72. PubMed ID: 27145743
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Pulmonary Hypertension in Patients With Severe Aortic Stenosis: Prognostic Impact After Transcatheter Aortic Valve Replacement: Pulmonary Hypertension in Patients Undergoing TAVR.
    Alushi B; Beckhoff F; Leistner D; Franz M; Reinthaler M; Stähli BE; Morguet A; Figulla HR; Doenst T; Maisano F; Falk V; Landmesser U; Lauten A
    JACC Cardiovasc Imaging; 2019 Apr; 12(4):591-601. PubMed ID: 29680341
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Long-Term Health Benefit of Transcatheter Aortic Valve Replacement in Patients With Chronic Lung Disease.
    Crestanello JA; Popma JJ; Adams DH; Deeb GM; Mumtaz M; George B; Huang J; Reardon MJ
    JACC Cardiovasc Interv; 2017 Nov; 10(22):2283-2293. PubMed ID: 29102579
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Changes in quality of life in patients with low-flow aortic stenosis undergoing transcatheter aortic valve replacement.
    Ahmed A; Alsidawi S; Bae R; Cavalcante J; Fukui M; Gössl M; Sorajja P; Garcia S
    Catheter Cardiovasc Interv; 2020 Oct; 96(4):972-978. PubMed ID: 32077618
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Prognostic significance of aortic valve gradient in patients with severe aortic stenosis undergoing transcatheter aortic valve replacement.
    Witberg G; Finkelstein A; Barbash I; Assali A; Shapira Y; Segev A; Halkin A; Fefer P; Ben-Shoshan J; Konigstein M; Sagie A; Guetta V; Kornowski R; Barsheshet A
    Catheter Cardiovasc Interv; 2017 Dec; 90(7):1175-1182. PubMed ID: 28544120
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Transcatheter Aortic Valve Replacement in Oncology Patients With Severe Aortic Stenosis.
    Landes U; Iakobishvili Z; Vronsky D; Zusman O; Barsheshet A; Jaffe R; Jubran A; Yoon SH; Makkar RR; Taramasso M; Russo M; Maisano F; Sinning JM; Shamekhi J; Biasco L; Pedrazzini G; Moccetti M; Latib A; Pagnesi M; Colombo A; Tamburino C; D' Arrigo P; Windecker S; Pilgrim T; Tchetche D; De Biase C; Guerrero M; Iftikhar O; Bosmans J; Bedzra E; Dvir D; Mylotte D; Sievert H; Watanabe Y; Søndergaard L; Dagnegård H; Codner P; Kodali S; Leon M; Kornowski R
    JACC Cardiovasc Interv; 2019 Jan; 12(1):78-86. PubMed ID: 30621982
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Long-Term Outcomes in Patients With New Permanent Pacemaker Implantation Following Transcatheter Aortic Valve Replacement.
    Chamandi C; Barbanti M; Munoz-Garcia A; Latib A; Nombela-Franco L; Gutiérrez-Ibanez E; Veiga-Fernandez G; Cheema AN; Cruz-Gonzalez I; Serra V; Tamburino C; Mangieri A; Colombo A; Jiménez-Quevedo P; Elizaga J; Laughlin G; Lee DH; Garcia Del Blanco B; Rodriguez-Gabella T; Marsal JR; Côté M; Philippon F; Rodés-Cabau J
    JACC Cardiovasc Interv; 2018 Feb; 11(3):301-310. PubMed ID: 29413244
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Acute effects of transcatheter aortic valve replacement on the ventricular-aortic interaction.
    Pagoulatou S; Stergiopulos N; Bikia V; Rovas G; Licker MJ; Müller H; Noble S; Adamopoulos D
    Am J Physiol Heart Circ Physiol; 2020 Dec; 319(6):H1451-H1458. PubMed ID: 33064556
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.