These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
5. Significant correlation between cerebral oximetry and carotid stump pressure during carotid endarterectomy. Lee TS; Hines GL; Feuerman M Ann Vasc Surg; 2008 Jan; 22(1):58-62. PubMed ID: 18023554 [TBL] [Abstract][Full Text] [Related]
6. The Diagnostic Accuracy of Intra-Operative Near Infrared Spectroscopy in Carotid Artery Endarterectomy Under Regional Anaesthesia: Systematic Review and Meta-Analysis. Duarte-Gamas L; Pereira-Neves A; Sousa J; Sousa-Pinto B; Rocha-Neves J Eur J Vasc Endovasc Surg; 2021 Oct; 62(4):522-531. PubMed ID: 34284934 [TBL] [Abstract][Full Text] [Related]
7. Good correlation between cerebral oxygenation measured using near infrared spectroscopy and stump pressure during carotid clamping. Yamamoto K; Miyata T; Nagawa H Int Angiol; 2007 Sep; 26(3):262-5. PubMed ID: 17622209 [TBL] [Abstract][Full Text] [Related]
8. Outcome of Near-Infrared Spectroscopy-Guided Selective Shunting During Carotid Endarterectomy in General Anesthesia. Kondov S; Beyersdorf F; Schöllhorn J; Benk C; Rylski B; Czerny M; Harloff A; Siepe M Ann Vasc Surg; 2019 Nov; 61():170-177. PubMed ID: 31299276 [TBL] [Abstract][Full Text] [Related]
9. Cerebral oximetry and stump pressure as indicators for shunting during carotid endarterectomy: comparative evaluation. Tambakis CL; Papadopoulos G; Sergentanis TN; Lagos N; Arnaoutoglou E; Labropoulos N; Matsagkas MI Vascular; 2011 Aug; 19(4):187-94. PubMed ID: 21764845 [TBL] [Abstract][Full Text] [Related]
10. Cerebral Neuromonitoring during Carotid Endarterectomy and Impact of Contralateral Internal Carotid Occlusion. Sef D; Skopljanac-Macina A; Milosevic M; Skrtic A; Vidjak V J Stroke Cerebrovasc Dis; 2018 May; 27(5):1395-1402. PubMed ID: 29397311 [TBL] [Abstract][Full Text] [Related]
11. Prospective single-center study on the reliability of ipsilateral cerebral oximetry using near-infrared spectroscopy as a predictor for selective shunting during carotid endarterectomy. Alhaizaey A; Yousif M; Azazy A; Saber A; Safan M; Elgamal GA; Almalki Y; Alhazmi B Vascular; 2024 Dec; 32(6):1304-1308. PubMed ID: 38281943 [TBL] [Abstract][Full Text] [Related]
12. The value of near-infrared spectroscopy measured cerebral oximetry during carotid endarterectomy in perioperative stroke prevention. A review. Pennekamp CW; Bots ML; Kappelle LJ; Moll FL; de Borst GJ Eur J Vasc Endovasc Surg; 2009 Nov; 38(5):539-45. PubMed ID: 19665397 [TBL] [Abstract][Full Text] [Related]
13. Correlation of cerebral oximetry with internal carotid artery stump pressures in carotid endarterectomy. Manwaring ML; Durham CA; McNally MM; Agle SC; Parker FM; Stoner MC Vasc Endovascular Surg; 2010 May; 44(4):252-6. PubMed ID: 20356866 [TBL] [Abstract][Full Text] [Related]
14. Prospective evaluation of electroencephalography, carotid artery stump pressure, and neurologic changes during 314 consecutive carotid endarterectomies performed in awake patients. Hans SS; Jareunpoon O J Vasc Surg; 2007 Mar; 45(3):511-5. PubMed ID: 17275248 [TBL] [Abstract][Full Text] [Related]
15. Impact of external carotid artery occlusion at declamping of the external and common carotid arteries during carotid endarterectomy on development of new postoperative ischemic cerebral lesions. Kobayashi M; Yoshida K; Kojima D; Oshida S; Fujiwara S; Kubo Y; Ogasawara K J Vasc Surg; 2019 Feb; 69(2):454-461. PubMed ID: 29960793 [TBL] [Abstract][Full Text] [Related]
16. Cerebral oximetry for the detection of cerebral ischemia during temporary carotid artery occlusion. Takeda N; Fujita K; Katayama S; Tamaki N Neurol Med Chir (Tokyo); 2000 Nov; 40(11):557-62; discussion 562-3. PubMed ID: 11109792 [TBL] [Abstract][Full Text] [Related]
17. Correlation of carotid artery stump pressure and neurologic changes during 474 carotid endarterectomies performed in awake patients. Calligaro KD; Dougherty MJ J Vasc Surg; 2005 Oct; 42(4):684-9. PubMed ID: 16242555 [TBL] [Abstract][Full Text] [Related]
18. Comparison of near-infrared spectroscopy and somatosensory evoked potentials for the detection of cerebral ischemia during carotid endarterectomy. Beese U; Langer H; Lang W; Dinkel M Stroke; 1998 Oct; 29(10):2032-7. PubMed ID: 9756577 [TBL] [Abstract][Full Text] [Related]
19. A clinical evaluation of near-infrared cerebral oximetry in the awake patient to monitor cerebral perfusion during carotid endarterectomy. Rigamonti A; Scandroglio M; Minicucci F; Magrin S; Carozzo A; Casati A J Clin Anesth; 2005 Sep; 17(6):426-30. PubMed ID: 16171662 [TBL] [Abstract][Full Text] [Related]
20. Modifications in Near Infrared Spectroscopy for Cerebral Monitoring During Carotid Endarterectomy in Asymptomatic and Symptomatic Patients. Bissacco D; Attisani L; Settembrini AM; Fossati A; Carmo M; Dallatana R; Settembrini PG Ann Vasc Surg; 2022 Feb; 79():239-246. PubMed ID: 34644636 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]