129 related articles for article (PubMed ID: 31943379)
1. A sensitive amperometric detection of neurotransmitter acetylcholine using carbon dot-modified carbon paste electrode.
Bodur OC; Dinç S; Özmen M; Arslan F
Biotechnol Appl Biochem; 2021 Feb; 68(1):20-29. PubMed ID: 31943379
[TBL] [Abstract][Full Text] [Related]
2. Development of an acetylcholinesterase-choline oxidase based biosensor for acetylcholine determination.
Tunç AT; Aynacı Koyuncu E; Arslan F
Artif Cells Nanomed Biotechnol; 2016 Nov; 44(7):1659-64. PubMed ID: 26367252
[TBL] [Abstract][Full Text] [Related]
3. Amperometric determination of acetylcholine-A neurotransmitter, by chitosan/gold-coated ferric oxide nanoparticles modified gold electrode.
Chauhan N; Pundir CS
Biosens Bioelectron; 2014 Nov; 61():1-8. PubMed ID: 24836212
[TBL] [Abstract][Full Text] [Related]
4. Choline-sensing carbon paste electrode containing polyaniline (pani)-silicon dioxide composite-modified choline oxidase.
Özdemir M; Arslan H
Artif Cells Nanomed Biotechnol; 2014 Feb; 42(1):27-31. PubMed ID: 23432401
[TBL] [Abstract][Full Text] [Related]
5. Amperometric choline biosensor based on multiwalled carbon nanotubes/zirconium oxide nanoparticles electrodeposited on glassy carbon electrode.
Pundir S; Chauhan N; Narang J; Pundir CS
Anal Biochem; 2012 Aug; 427(1):26-32. PubMed ID: 22561918
[TBL] [Abstract][Full Text] [Related]
6. Bienzymatic amperometric biosensor for choline based on mediator thionine in situ electropolymerized within a carbon paste electrode.
Yang M; Yang Y; Yang Y; Shen G; Yu R
Anal Biochem; 2004 Nov; 334(1):127-34. PubMed ID: 15464961
[TBL] [Abstract][Full Text] [Related]
7. Detection of pesticides using an amperometric biosensor based on ferophthalocyanine chemically modified carbon paste electrode and immobilized bienzymatic system.
Ciucu AA; Negulescu C; Baldwin RP
Biosens Bioelectron; 2003 Mar; 18(2-3):303-10. PubMed ID: 12485777
[TBL] [Abstract][Full Text] [Related]
8. Amperometric acetylcholine biosensor based on self-assembly of gold nanoparticles and acetylcholinesterase on the sol-gel/multi-walled carbon nanotubes/choline oxidase composite-modified platinum electrode.
Hou S; Ou Z; Chen Q; Wu B
Biosens Bioelectron; 2012 Mar; 33(1):44-9. PubMed ID: 22230694
[TBL] [Abstract][Full Text] [Related]
9. Carbon fibre-based microbiosensors for in vivo measurements of acetylcholine and choline.
Schuvailo ON; Dzyadevych SV; El'skaya AV; Gautier-Sauvigné S; Csöregi E; Cespuglio R; Soldatkin AP
Biosens Bioelectron; 2005 Jul; 21(1):87-94. PubMed ID: 15967355
[TBL] [Abstract][Full Text] [Related]
10. Amperometric sensors for peroxide, choline, and acetylcholine based on electron transfer between horseradish peroxidase and a redox polymer.
Garguilo MG; Huynh N; Proctor A; Michael AC
Anal Chem; 1993 Mar; 65(5):523-8. PubMed ID: 8452244
[TBL] [Abstract][Full Text] [Related]
11. Glucose biosensor based on immobilization of glucose oxidase on a carbon paste electrode modified with microsphere-attached l-glycine.
Donmez S; Arslan F; Sarı N; Hasanoğlu Özkan E; Arslan H
Biotechnol Appl Biochem; 2017 Sep; 64(5):745-753. PubMed ID: 27629272
[TBL] [Abstract][Full Text] [Related]
12. Immobilization of acetylcholineesterase-choline oxidase on a gold-platinum bimetallic nanoparticles modified glassy carbon electrode for the sensitive detection of organophosphate pesticides, carbamates and nerve agents.
Upadhyay S; Rao GR; Sharma MK; Bhattacharya BK; Rao VK; Vijayaraghavan R
Biosens Bioelectron; 2009 Dec; 25(4):832-8. PubMed ID: 19762223
[TBL] [Abstract][Full Text] [Related]
13. Multienzyme microbiosensor based on electropolymerized o-phenylenediamine for simultaneous in vitro determination of acetylcholine and choline.
Khan A; Ab Ghani S
Biosens Bioelectron; 2012 Jan; 31(1):433-8. PubMed ID: 22154168
[TBL] [Abstract][Full Text] [Related]
14. A sensitive amperometric acetylcholine biosensor based on carbon nanosphere and acetylcholinesterase modified electrode for detection of pesticide residues.
Cai JR; Zhou LN; Han E
Anal Sci; 2014; 30(6):669-73. PubMed ID: 24919672
[TBL] [Abstract][Full Text] [Related]
15. Electrosynthesized poly(pyrrole)/poly(2-naphthol) bilayer membrane as an effective anti-interference layer for simultaneous determination of acethylcholine and choline by a dual electrode amperometric biosensor.
Guerrieri A; Lattanzio V; Palmisano F; Zambonin PG
Biosens Bioelectron; 2006 Mar; 21(9):1710-8. PubMed ID: 16169212
[TBL] [Abstract][Full Text] [Related]
16. A sensitive biosensor for the fluorescence detection of the acetylcholinesterase reaction system based on carbon dots.
Ren X; Wei J; Ren J; Qiang L; Tang F; Meng X
Colloids Surf B Biointerfaces; 2015 Jan; 125():90-5. PubMed ID: 25500325
[TBL] [Abstract][Full Text] [Related]
17. Preparation of carbon paste electrodes including poly(styrene) attached glycine-Pt(IV) for amperometric detection of glucose.
Dönmez S; Arslan F; Sarı N; Kurnaz Yetim N; Arslan H
Biosens Bioelectron; 2014 Apr; 54():146-50. PubMed ID: 24269757
[TBL] [Abstract][Full Text] [Related]
18. An amperometric acetylcholine biosensor based on a conducting polymer.
Kanik FE; Kolb M; Timur S; Bahadir M; Toppare L
Int J Biol Macromol; 2013 Aug; 59():111-8. PubMed ID: 23603072
[TBL] [Abstract][Full Text] [Related]
19. Electrocatalytic microelectrode detectors for choline and acetylcholine following separation by capillary electrophoresis.
Mukherjee J; Kirchhoff JR
Anal Chem; 2009 Aug; 81(16):6996-7002. PubMed ID: 20337384
[TBL] [Abstract][Full Text] [Related]
20. An acetylcholinesterase/choline oxidase-based amperometric biosensors as a liquid chromatography detector for acetylcholine and choline determination in brain tissue homogenates.
Guerrieri A; Palmisano F
Anal Chem; 2001 Jul; 73(13):2875-82. PubMed ID: 11467530
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]