These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
183 related articles for article (PubMed ID: 3194446)
1. Influence of the variation of energy spectra with depth in the dosimetry of 192Ir using LiF TLD. Meigooni AS; Meli JA; Nath R Phys Med Biol; 1988 Oct; 33(10):1159-70. PubMed ID: 3194446 [TBL] [Abstract][Full Text] [Related]
2. In-phantom response of LiF TLD-100 for dosimetry of 192Ir HDR source. Pradhan AS; Quast U Med Phys; 2000 May; 27(5):1025-9. PubMed ID: 10841406 [TBL] [Abstract][Full Text] [Related]
3. Using LiF:Mg,Cu,P TLDs to estimate the absorbed dose to water in liquid water around an 192Ir brachytherapy source. Lucas PA; Aubineau-Lanièce I; Lourenço V; Vermesse D; Cutarella D Med Phys; 2014 Jan; 41(1):011711. PubMed ID: 24387503 [TBL] [Abstract][Full Text] [Related]
4. Response of LiF:Mg,Ti thermoluminescent dosimeters at photon energies relevant to the dosimetry of brachytherapy (<1 MeV). Tedgren AC; Hedman A; Grindborg JE; Carlsson GA Med Phys; 2011 Oct; 38(10):5539-50. PubMed ID: 21992372 [TBL] [Abstract][Full Text] [Related]
5. Determination of the intrinsic energy dependence of LiF:Mg,Ti thermoluminescent dosimeters for 125I and 103Pd brachytherapy sources relative to 60Co. Reed JL; Rasmussen BE; Davis SD; Micka JA; Culberson WS; DeWerd LA Med Phys; 2014 Dec; 41(12):122103. PubMed ID: 25471976 [TBL] [Abstract][Full Text] [Related]
6. Whole-body dose and energy measurements in radiotherapy by a combination of LiF:Mg,Cu,P and LiF:Mg,Ti. Hauri P; Schneider U Z Med Phys; 2018 Apr; 28(2):96-109. PubMed ID: 28807441 [TBL] [Abstract][Full Text] [Related]
7. LiF:Mg,Ti TLD response as a function of photon energy for moderately filtered x-ray spectra in the range of 20-250 kVp relative to 60Co. Nunn AA; Davis SD; Micka JA; DeWerd LA Med Phys; 2008 May; 35(5):1859-69. PubMed ID: 18561661 [TBL] [Abstract][Full Text] [Related]
8. TLD, diode and Monte Carlo dosimetry of an 192Ir source for high dose-rate brachytherapy. Kirov As; Williamson JF; Meigooni AS; Zhu Y Phys Med Biol; 1995 Dec; 40(12):2015-36. PubMed ID: 8719942 [TBL] [Abstract][Full Text] [Related]
9. Monte Carlo and TLD dosimetry of an 192Ir high dose-rate brachytherapy source. Karaiskos P; Angelopoulos A; Sakelliou L; Sandilos P; Antypas C; Vlachos L; Koutsouveli E Med Phys; 1998 Oct; 25(10):1975-84. PubMed ID: 9800706 [TBL] [Abstract][Full Text] [Related]
10. Variations in dose response with x-ray energy of LiF:Mg,Cu,P thermoluminescence dosimeters: implications for clinical dosimetry. Duggan L; Hood C; Warren-Forward H; Haque M; Kron T Phys Med Biol; 2004 Sep; 49(17):3831-45. PubMed ID: 15470908 [TBL] [Abstract][Full Text] [Related]
11. Response of LiF-TLD micro-rods around 125I radioactive seed. Mobit P; Badragan I Phys Med Biol; 2003 Oct; 48(19):3129-42. PubMed ID: 14579856 [TBL] [Abstract][Full Text] [Related]
13. Miniature LiF:Mg,Cu,P TLDs to study the effect of applicator material in 192-Ir brachytherapy. Hood C; Duggan L; Bazley S; Denham J; Kron T Australas Phys Eng Sci Med; 2006 Dec; 29(4):300-2. PubMed ID: 17260583 [TBL] [Abstract][Full Text] [Related]
14. Determination of absorbed dose to water around a clinical HDR (192)Ir source using LiF:Mg,Ti TLDs demonstrates an LET dependence of detector response. Carlsson Tedgren A; Elia R; Hedtjarn H; Olsson S; Alm Carlsson G Med Phys; 2012 Feb; 39(2):1133-40. PubMed ID: 22320824 [TBL] [Abstract][Full Text] [Related]
15. Radial dose distribution of 192Ir and 137Cs seed sources. Thomason C; Higgins P Med Phys; 1989; 16(2):254-7. PubMed ID: 2716705 [TBL] [Abstract][Full Text] [Related]
16. Angular and radial dependence of the energy response factor for LIF-TLD micro-rods in 125L permanent implant source. Mobit P; Badragan I Radiat Prot Dosimetry; 2006; 120(1-4):70-3. PubMed ID: 16782977 [TBL] [Abstract][Full Text] [Related]
17. Calculation of the TLD700:LiF energy response from Ir-192 using novel Monte Carlo and empirical methods. Rijken JD; Harris-Phillips W; Lawson JM Australas Phys Eng Sci Med; 2015 Mar; 38(1):129-38. PubMed ID: 25663432 [TBL] [Abstract][Full Text] [Related]
18. Evaluation of a lithium formate EPR dosimetry system for dose measurements around 192Ir brachytherapy sources. Antonovic L; Gustafsson H; Carlsson GA; Carlsson Tedgren A Med Phys; 2009 Jun; 36(6):2236-47. PubMed ID: 19610313 [TBL] [Abstract][Full Text] [Related]
19. The dose distribution surrounding 192Ir and 137Cs seed sources. Thomason C; Mackie TR; Lindstrom MJ; Higgins PD Phys Med Biol; 1991 Apr; 36(4):475-93. PubMed ID: 2047397 [TBL] [Abstract][Full Text] [Related]
20. Accuracy of Monte Carlo photon transport simulation in characterizing brachytherapy dosimeter energy-response artefacts. Das RK; Li Z; Perera H; Williamson JF Phys Med Biol; 1996 Jun; 41(6):995-1006. PubMed ID: 8794480 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]