These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 31947128)

  • 41. A Novel Sensor-Array System for Contactless Electrocardiogram Acquisition.
    Weeks J; Elsaadany M; Lessard-Tremblay M; Targino L; Liamini M; Gagnon G
    Annu Int Conf IEEE Eng Med Biol Soc; 2020 Jul; 2020():4122-4125. PubMed ID: 33018905
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Vital Sign Monitoring Using Capacitive Sensing.
    Jovanov E
    Annu Int Conf IEEE Eng Med Biol Soc; 2018 Jul; 2018():5930-5933. PubMed ID: 30441686
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Automatic detection of ECG electrode misplacement: a tale of two algorithms.
    Xia H; Garcia GA; Zhao X
    Physiol Meas; 2012 Sep; 33(9):1549-61. PubMed ID: 22903067
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Suppression of MR gradient artefacts on electrophysiological signals based on an adaptive real-time filter with LMS coefficient updates.
    Abächerli R; Pasquier C; Odille F; Kraemer M; Schmid JJ; Felblinger J
    MAGMA; 2005 Mar; 18(1):41-50. PubMed ID: 15700133
    [TBL] [Abstract][Full Text] [Related]  

  • 45. A Practical Method to Reduce Electrode Mismatch Artefacts during 4-electrode BioImpedance Spectroscopy Measurements.
    Montalibet A; McAdams E
    Annu Int Conf IEEE Eng Med Biol Soc; 2018 Jul; 2018():5775-5779. PubMed ID: 30441648
    [TBL] [Abstract][Full Text] [Related]  

  • 46. A capacitive ECG array with visual patient feedback.
    Eilebrecht B; Schommartz A; Walter M; Wartzek T; Czaplik M; Leonhardt S
    Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():6539-42. PubMed ID: 21096501
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Multichannel techniques for motion artifacts removal from electrocardiographic signals.
    Milanesi M; Martini N; Vanello N; Positano V; Santarelli MF; Paradiso R; De Rossi D; Landini L
    Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():3391-4. PubMed ID: 17946178
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Effect of adaptive motion-artifact reduction on QRS detection.
    Hamilton PS; Curley M; Aimi R
    Biomed Instrum Technol; 2000; 34(3):197-202. PubMed ID: 10868261
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Real-time Evaluation of ECG Acquisition Systems through Signal Quality Assessment in Horses during Submaximal Treadmill Test.
    Nardelli M; Lanata A; Valenza G; Sgorbini M; Baragli P; Scilingo EP
    Annu Int Conf IEEE Eng Med Biol Soc; 2018 Jul; 2018():498-501. PubMed ID: 30440443
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Correlation-based ECG Artifact Correction from Single Channel EEG using Modified Variational Mode Decomposition.
    Dora C; Biswal PK
    Comput Methods Programs Biomed; 2020 Jan; 183():105092. PubMed ID: 31600608
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Design of a novel flexible capacitive sensing mattress for monitoring sleeping respiratory.
    Chang WY; Huang CC; Chen CC; Chang CC; Yang CL
    Sensors (Basel); 2014 Nov; 14(11):22021-38. PubMed ID: 25420152
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Heart Rate Variability Monitoring during Sleep Based on Capacitively Coupled Textile Electrodes on a Bed.
    Lee HJ; Hwang SH; Yoon HN; Lee WK; Park KS
    Sensors (Basel); 2015 May; 15(5):11295-311. PubMed ID: 26007716
    [TBL] [Abstract][Full Text] [Related]  

  • 53. A simple measure to control for variations in chest electrodes placement in serial electrocardiogram recordings.
    Soliman EZ
    J Electrocardiol; 2008; 41(5):378-9. PubMed ID: 18620704
    [TBL] [Abstract][Full Text] [Related]  

  • 54. ECG-Quality Assessment of Dry-Electrode Cooperative Sensors.
    Rapin M; Wacker J; Ferrario D; Haenni E; Dasen S; Chéhelat O
    Stud Health Technol Inform; 2020 Jun; 270():751-755. PubMed ID: 32570483
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Stress Level Detection Based on the Capacitive Electrocardiogram Signals of Driving Subjects.
    Škorić T
    Sensors (Basel); 2023 Nov; 23(22):. PubMed ID: 38005545
    [TBL] [Abstract][Full Text] [Related]  

  • 56. ECG denoising based on the empirical mode decomposition.
    Weng B; Blanco-Velasco M; Barner KE
    Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():1-4. PubMed ID: 17945967
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Sensitivity of CIPS-computed PVC location to measurement errors in ECG electrode position: the need for the 3D camera.
    van Dam PM; Gordon JP; Laks M
    J Electrocardiol; 2014; 47(6):788-93. PubMed ID: 25194874
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Artefacts in continuous ECG recordings--provoking and preventing manoeuvres.
    Lönnblad J; Nilsson G; Folke M; Hök B; Lindén M; Bäcklund Y
    Scand Cardiovasc J; 2005 Jul; 39(3):167-71. PubMed ID: 16146979
    [TBL] [Abstract][Full Text] [Related]  

  • 59. [ECG artefacts after electrode misplacements].
    Thaler T; Rudiger A
    Praxis (Bern 1994); 2009 Jan; 98(1):17-21. PubMed ID: 19374204
    [TBL] [Abstract][Full Text] [Related]  

  • 60. A Novel Framework for Motion-Tolerant Instantaneous Heart Rate Estimation by Phase-Domain Multiview Dynamic Time Warping.
    Zhang Q; Zhou D; Zeng X
    IEEE Trans Biomed Eng; 2017 Nov; 64(11):2562-2574. PubMed ID: 28113198
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.