These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

162 related articles for article (PubMed ID: 31948588)

  • 1. Online coupling of an electrochemically fabricated solid-phase microextraction probe and a miniature mass spectrometer for enrichment and analysis of chemical contaminants in infant drinks.
    Guo X; Bai H; Ma X; Li J; Ren Y; Ouyang Z; Ma Q
    Anal Chim Acta; 2020 Feb; 1098():66-74. PubMed ID: 31948588
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Sensitive analysis of trace macrolide antibiotics in complex food samples by ambient mass spectrometry with molecularly imprinted polymer-coated wooden tips.
    Liu Y; Yang Q; Chen X; Song Y; Wu Q; Yang Y; He L
    Talanta; 2019 Nov; 204():238-247. PubMed ID: 31357288
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Online hyphenation of in-capillary aptamer-functionalized solid-phase microextraction and extraction nanoelectrospray ionization for miniature mass spectrometry analysis.
    Lv Y; Shang Y; Li L; Zhang Y; Ma Q
    Analyst; 2023 Apr; 148(8):1815-1823. PubMed ID: 36939082
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Coupling solid-phase microextraction with ambient mass spectrometry using surface coated wooden-tip probe for rapid analysis of ultra trace perfluorinated compounds in complex samples.
    Deng J; Yang Y; Fang L; Lin L; Zhou H; Luan T
    Anal Chem; 2014 Nov; 86(22):11159-66. PubMed ID: 25354323
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Direct coupling of solid phase microextraction with electrospray ionization mass spectrometry: A Case study for detection of ketamine in urine.
    Hu B; Zheng B; Rickert D; Gómez-Ríos GA; Bojko B; Pawliszyn J; Yao ZP
    Anal Chim Acta; 2019 Oct; 1075():112-119. PubMed ID: 31196416
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A comparison study on a sulfonated graphene-polyaniline nanocomposite coated fiber for analysis of nicotine in solid samples through the traditional and vacuum-assisted HS-SPME.
    Ghiasvand A; Koonani S; Yazdankhah F; Farhadi S
    J Pharm Biomed Anal; 2018 Feb; 149():271-277. PubMed ID: 29128827
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A nanocomposite prepared from a polypyrrole deep eutectic solvent and coated onto the inner surface of a steel capillary for electrochemically controlled microextraction of acidic drugs such as losartan.
    Asiabi H; Yamini Y; Shamsayei M; Mehraban JA
    Mikrochim Acta; 2018 Feb; 185(3):169. PubMed ID: 29594451
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Direct identification of prohibited substances in cosmetics and foodstuffs using ambient ionization on a miniature mass spectrometry system.
    Ma Q; Bai H; Li W; Wang C; Li X; Cooks RG; Ouyang Z
    Anal Chim Acta; 2016 Mar; 912():65-73. PubMed ID: 26920774
    [TBL] [Abstract][Full Text] [Related]  

  • 9. An electrochemically enhanced solid-phase microextraction approach based on molecularly imprinted polypyrrole/multi-walled carbon nanotubes composite coating for selective extraction of fluoroquinolones in aqueous samples.
    Liu X; Wang X; Tan F; Zhao H; Quan X; Chen J; Li L
    Anal Chim Acta; 2012 May; 727():26-33. PubMed ID: 22541819
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Sensitive determination of bisphenol A and bisphenol F in canned food using a solid-phase microextraction fibre coated with single-walled carbon nanotubes before GC/MS.
    Rastkari N; Ahmadkhaniha R; Yunesian M; Baleh LJ; Mesdaghinia A
    Food Addit Contam Part A Chem Anal Control Expo Risk Assess; 2010 Oct; 27(10):1460-8. PubMed ID: 20658403
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Aptamer-functionalized solid phase microextraction-liquid chromatography/tandem mass spectrometry for selective enrichment and determination of thrombin.
    Du F; Alam MN; Pawliszyn J
    Anal Chim Acta; 2014 Oct; 845():45-52. PubMed ID: 25201271
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Surface-coated wooden-tip electrospray ionization mass spectrometry for determination of trace fluoroquinolone and macrolide antibiotics in water.
    Deng J; Yu T; Yao Y; Peng Q; Luo L; Chen B; Wang X; Yang Y; Luan T
    Anal Chim Acta; 2017 Feb; 954():52-59. PubMed ID: 28081814
    [TBL] [Abstract][Full Text] [Related]  

  • 13. In-situ growth of covalent organic framework on stainless steel needles as solid-phase microextraction probe coupled with electrospray ionization mass spectrometry for rapid and sensitive determination of tricyclic antidepressants in biosamples.
    Yuan J; Huang W; Tong W; Chen Z; Li H; Chen J; Lin Z
    J Chromatogr A; 2023 Apr; 1695():463955. PubMed ID: 37004299
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Direct coupling in-tube solid-phase microextraction with mass spectrometry using polymer coated open-tubular column for rapid analysis of antiepileptic drugs in biofluids.
    Hu W; Zhou W; Wang C; Liu Z; Chen Z
    Anal Chim Acta; 2023 Feb; 1240():340775. PubMed ID: 36641145
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Analysis of food samples made easy by microextraction technologies directly coupled to mass spectrometry.
    Gionfriddo E; Gómez-Ríos GA
    J Mass Spectrom; 2021 Jan; 56(1):e4665. PubMed ID: 33098354
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A solid-phase microextraction platinized stainless steel fiber coated with a multiwalled carbon nanotube-polyaniline nanocomposite film for the extraction of thymol and carvacrol in medicinal plants and honey.
    Ghiasvand A; Dowlatshah S; Nouraei N; Heidari N; Yazdankhah F
    J Chromatogr A; 2015 Aug; 1406():87-93. PubMed ID: 26138604
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Solid-phase microextraction- probe electrospray ionization devices for screening and quantitating drugs of abuse in small amounts of biofluids.
    Thirukumaran M; Singh V; Arao Y; Fujito Y; Nishimura M; Ogura T; Pawliszyn J
    Talanta; 2021 Aug; 231():122317. PubMed ID: 33965011
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Online coupling of matrix solid-phase dispersion to direct analysis in real time mass spectrometry for high-throughput analysis of regulated chemicals in consumer products.
    Meng X; Sun S; Bai H; Ma Q
    Anal Chim Acta; 2023 Jan; 1239():340677. PubMed ID: 36628757
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A novel Schiff base network-1 nanocomposite coated fiber for solid-phase microextraction of phenols from honey samples.
    Wang W; Wang J; Zhang S; Cui P; Wang C; Wang Z
    Talanta; 2016 Dec; 161():22-30. PubMed ID: 27769400
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Carbon fiber ionization mass spectrometry coupled with solid phase microextraction for analysis of Benzo[a]pyrene.
    Wu ML; Chen TY; Chen WJ; Fahad Baig MM; Wu YC; Chen YC
    Anal Chim Acta; 2019 Feb; 1049():133-140. PubMed ID: 30612644
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.