These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

115 related articles for article (PubMed ID: 31951204)

  • 1. Impact of bioresorbable scaffold design characteristics on local haemodynamic forces: an ex vivo assessment with computational fluid dynamics simulations.
    Tarrahi I; Colombo M; Hartman EMJ; Tovar Forero MN; Torii R; Chiastra C; Daemen J; Gijsen FJH
    EuroIntervention; 2020 Dec; 16(11):e930-e937. PubMed ID: 31951204
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Difference in haemodynamic microenvironment in vessels scaffolded with Absorb BVS and Mirage BRMS: insights from a preclinical endothelial shear stress study.
    Tenekecioglu E; Torii R; Bourantas C; Sotomi Y; Cavalcante R; Zeng Y; Collet C; Crake T; Suwannasom P; Onuma Y; Serruys PW
    EuroIntervention; 2017 Dec; 13(11):1327-1335. PubMed ID: 28590249
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Strut protrusion and shape impact on endothelial shear stress: insights from pre-clinical study comparing Mirage and Absorb bioresorbable scaffolds.
    Tenekecioglu E; Sotomi Y; Torii R; Bourantas C; Miyazaki Y; Collet C; Crake T; Su S; Onuma Y; Serruys PW
    Int J Cardiovasc Imaging; 2017 Sep; 33(9):1313-1322. PubMed ID: 28365819
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Hemodynamic analysis of a novel bioresorbable scaffold in porcine coronary artery model.
    Tenekecioglu E; Torii R; Bourantas CV; Cavalcante R; Sotomi Y; Zeng Y; Collet C; Crake T; Abizaid A; Onuma Y; Su S; Santoso T; Serruys PW
    Catheter Cardiovasc Interv; 2018 May; 91(6):1084-1091. PubMed ID: 28843033
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Post-implantation shear stress assessment: an emerging tool for differentiation of bioresorbable scaffolds.
    Tenekecioglu E; Torii R; Katagiri Y; Chichareon P; Asano T; Miyazaki Y; Takahashi K; Modolo R; Al-Lamee R; Al-Lamee K; Colet C; Reiber JHC; Pekkan K; van Geuns R; Bourantas CV; Onuma Y; Serruys PW
    Int J Cardiovasc Imaging; 2019 Mar; 35(3):409-418. PubMed ID: 30426299
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Flow patterns at stented coronary bifurcations: computational fluid dynamics analysis.
    Katritsis DG; Theodorakakos A; Pantos I; Gavaises M; Karcanias N; Efstathopoulos EP
    Circ Cardiovasc Interv; 2012 Aug; 5(4):530-9. PubMed ID: 22763345
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Computational fluid dynamics analysis of balloon-expandable coronary stents: influence of stent and vessel deformation.
    Martin DM; Murphy EA; Boyle FJ
    Med Eng Phys; 2014 Aug; 36(8):1047-56. PubMed ID: 24953569
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Assessment of the hemodynamic characteristics of Absorb BVS in a porcine coronary artery model.
    Tenekecioglu E; Torii R; Bourantas C; Abdelghani M; Cavalcante R; Sotomi Y; Crake T; Su S; Santoso T; Onuma Y; Serruys PW
    Int J Cardiol; 2017 Jan; 227():467-473. PubMed ID: 27839816
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Hemodynamic Performance of a New Punched Stent Strut: A Numerical Study.
    Xue Y; Liu X; Sun A; Zhang P; Fan Y; Deng X
    Artif Organs; 2016 Jul; 40(7):669-77. PubMed ID: 26581476
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Haemodynamic assessment of human coronary arteries is affected by degree of freedom of artery movement.
    Javadzadegan A; Yong AS; Chang M; Ng MK; Behnia M; Kritharides L
    Comput Methods Biomech Biomed Engin; 2017 Feb; 20(3):260-272. PubMed ID: 27467730
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Hemodynamic alternations following stent deployment and post-dilation in a heavily calcified coronary artery: In silico and ex-vivo approaches.
    Gamage PT; Dong P; Lee J; Gharaibeh Y; Zimin VN; Dallan LAP; Bezerra HG; Wilson DL; Gu L
    Comput Biol Med; 2021 Dec; 139():104962. PubMed ID: 34715552
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Haemodynamic effects of incomplete stent apposition in curved coronary arteries.
    Chen WX; Poon EKW; Thondapu V; Hutchins N; Barlis P; Ooi A
    J Biomech; 2017 Oct; 63():164-173. PubMed ID: 29032800
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Local hemodynamics at the rupture point of cerebral aneurysms determined by computational fluid dynamics analysis.
    Omodaka S; Sugiyama S; Inoue T; Funamoto K; Fujimura M; Shimizu H; Hayase T; Takahashi A; Tominaga T
    Cerebrovasc Dis; 2012; 34(2):121-9. PubMed ID: 22965244
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Local Flow Patterns After Implantation of Bioresorbable Vascular Scaffold in Coronary Bifurcations - Novel Findings by Computational Fluid Dynamics.
    Li Y; Li Z; Holck EN; Xu B; Karanasos A; Fei Z; Chang Y; Chu M; Dijkstra J; Christiansen EH; Reiber JHC; Holm NR; Tu S
    Circ J; 2018 May; 82(6):1575-1583. PubMed ID: 29576586
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Magnetohydrodynamic blood flow in patients with coronary artery disease.
    Javadzadegan A; Moshfegh A; Afrouzi HH; Omidi M
    Comput Methods Programs Biomed; 2018 Sep; 163():111-122. PubMed ID: 30119846
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Local hemodynamic changes caused by main branch stent implantation and subsequent virtual side branch balloon angioplasty in a representative coronary bifurcation.
    Williams AR; Koo BK; Gundert TJ; Fitzgerald PJ; LaDisa JF
    J Appl Physiol (1985); 2010 Aug; 109(2):532-40. PubMed ID: 20507966
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Impact of bifurcation angle and other anatomical characteristics on blood flow - A computational study of non-stented and stented coronary arteries.
    Beier S; Ormiston J; Webster M; Cater J; Norris S; Medrano-Gracia P; Young A; Cowan B
    J Biomech; 2016 Jun; 49(9):1570-1582. PubMed ID: 27062590
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Endothelial shear stress 5 years after implantation of a coronary bioresorbable scaffold.
    Thondapu V; Tenekecioglu E; Poon EKW; Collet C; Torii R; Bourantas CV; Chin C; Sotomi Y; Jonker H; Dijkstra J; Revalor E; Gijsen F; Onuma Y; Ooi A; Barlis P; Serruys PW
    Eur Heart J; 2018 May; 39(18):1602-1609. PubMed ID: 29409057
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Hemodynamic and morphological characteristics of a growing cerebral aneurysm.
    Dabagh M; Nair P; Gounley J; Frakes D; Gonzalez LF; Randles A
    Neurosurg Focus; 2019 Jul; 47(1):E13. PubMed ID: 31261117
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Computational fluid dynamics characterization of pulsatile flow in central and Sano shunts connected to the pulmonary arteries: importance of graft angulation on shear stress-induced, platelet-mediated thrombosis.
    Ascuitto R; Ross-Ascuitto N; Guillot M; Celestin C
    Interact Cardiovasc Thorac Surg; 2017 Sep; 25(3):414-421. PubMed ID: 28525548
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.