These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

161 related articles for article (PubMed ID: 31952802)

  • 21. Real-Time Measurement of the Liquid Amount in Cryo-Electron Microscopy Grids Using Laser Diffraction of Regular 2-D Holes of the Grids.
    Ahn J; Lee D; Jo I; Jeong H; Hyun JK; Woo JS; Choi SH; Ha NC
    Mol Cells; 2020 Mar; 43(3):298-303. PubMed ID: 32150795
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Bioactive Functionalized Monolayer Graphene for High-Resolution Cryo-Electron Microscopy.
    Liu N; Zhang J; Chen Y; Liu C; Zhang X; Xu K; Wen J; Luo Z; Chen S; Gao P; Jia K; Liu Z; Peng H; Wang HW
    J Am Chem Soc; 2019 Mar; 141(9):4016-4025. PubMed ID: 30724081
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Preparation of High-Temperature Sample Grids for Cryo-EM.
    Chang YC; Chen CY; Tsai MD
    J Vis Exp; 2021 Jul; (173):. PubMed ID: 34369929
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Cryo Electron Microscopy of TRP Channels.
    Samanta A; Hughes TET; Moiseenkova-Bell VY
    Methods Mol Biol; 2019; 1987():39-50. PubMed ID: 31028672
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Improved sample dispersion in cryo-EM using "perpetually-hydrated" graphene oxide flakes.
    Cheung M; Adaniya H; Cassidy C; Yamashita M; Li KL; Taba S; Shintake T
    J Struct Biol; 2018 Oct; 204(1):75-79. PubMed ID: 30030043
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Routine determination of ice thickness for cryo-EM grids.
    Rice WJ; Cheng A; Noble AJ; Eng ET; Kim LY; Carragher B; Potter CS
    J Struct Biol; 2018 Oct; 204(1):38-44. PubMed ID: 29981485
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Polyelectrolyte coating of cryo-EM grids improves lateral distribution and prevents aggregation of macromolecules.
    Hrebík D; Gondová M; Valentová L; Füzik T; Přidal A; Nováček J; Plevka P
    Acta Crystallogr D Struct Biol; 2022 Nov; 78(Pt 11):1337-1346. PubMed ID: 36322417
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Low-cost cryo-light microscopy stage fabrication for correlated light/electron microscopy.
    Carlson DB; Evans JE
    J Vis Exp; 2011 Jun; (52):. PubMed ID: 21673645
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Uniform thin ice on ultraflat graphene for high-resolution cryo-EM.
    Zheng L; Liu N; Gao X; Zhu W; Liu K; Wu C; Yan R; Zhang J; Gao X; Yao Y; Deng B; Xu J; Lu Y; Liu Z; Li M; Wei X; Wang HW; Peng H
    Nat Methods; 2023 Jan; 20(1):123-130. PubMed ID: 36522503
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A simple and robust procedure for preparing graphene-oxide cryo-EM grids.
    Palovcak E; Wang F; Zheng SQ; Yu Z; Li S; Betegon M; Bulkley D; Agard DA; Cheng Y
    J Struct Biol; 2018 Oct; 204(1):80-84. PubMed ID: 30017701
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Sample deposition onto cryo-EM grids: from sprays to jets and back.
    Klebl DP; Monteiro DCF; Kontziampasis D; Kopf F; Sobott F; White HD; Trebbin M; Muench SP
    Acta Crystallogr D Struct Biol; 2020 Apr; 76(Pt 4):340-349. PubMed ID: 32254058
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Toward Compositional Contrast by Cryo-STEM.
    Elbaum M; Seifer S; Houben L; Wolf SG; Rez P
    Acc Chem Res; 2021 Oct; 54(19):3621-3631. PubMed ID: 34491730
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Specimen Preparation for High-Resolution Cryo-EM.
    Passmore LA; Russo CJ
    Methods Enzymol; 2016; 579():51-86. PubMed ID: 27572723
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Biological Applications at the Cutting Edge of Cryo-Electron Microscopy.
    Dillard RS; Hampton CM; Strauss JD; Ke Z; Altomara D; Guerrero-Ferreira RC; Kiss G; Wright ER
    Microsc Microanal; 2018 Aug; 24(4):406-419. PubMed ID: 30175702
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A Fast and Effective Microfluidic Spraying-Plunging Method for High-Resolution Single-Particle Cryo-EM.
    Feng X; Fu Z; Kaledhonkar S; Jia Y; Shah B; Jin A; Liu Z; Sun M; Chen B; Grassucci RA; Ren Y; Jiang H; Frank J; Lin Q
    Structure; 2017 Apr; 25(4):663-670.e3. PubMed ID: 28286002
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Light 'Em up: Efficient Screening of Gold Foil Grids in Cryo-EM.
    Hagen WJH
    Front Mol Biosci; 2022; 9():912363. PubMed ID: 35693551
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Deformed grids for single-particle cryo-electron microscopy of specimens exhibiting a preferred orientation.
    Liu Y; Meng X; Liu Z
    J Struct Biol; 2013 Jun; 182(3):255-8. PubMed ID: 23537848
    [TBL] [Abstract][Full Text] [Related]  

  • 38. A cryo-electron microscopy support film formed by 2D crystals of hydrophobin HFBI.
    Fan H; Wang B; Zhang Y; Zhu Y; Song B; Xu H; Zhai Y; Qiao M; Sun F
    Nat Commun; 2021 Dec; 12(1):7257. PubMed ID: 34907237
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Thicker Ice Improves the Integrity and Angular Distribution of CDC48A Hexamers on Cryo-EM Grids.
    Huntington B; Zhao L; Bron P; Shahul Hameed UF; Arold ST; Qureshi BM
    Front Mol Biosci; 2022; 9():890390. PubMed ID: 35782862
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Maintaining Context in Ice: Cryo-EM/ET Workflow Optimizations.
    Elad N; Wolf SG
    Structure; 2020 Nov; 28(11):1179-1181. PubMed ID: 33147474
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.