These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
115 related articles for article (PubMed ID: 3195438)
1. The effect of ionic contrast medium on the movement of acutely ischemic and nonischemic canine myocardium. Noma S; Askenase AD; Agarwal JB; Helfant RH Am Heart J; 1988 Dec; 116(6 Pt 1):1536-41. PubMed ID: 3195438 [TBL] [Abstract][Full Text] [Related]
2. Augmentation of contraction in remote nonischemic zone during acute ischemia. Noma S; Askenase AD; Weintraub WS; Klein LW; Agarwal JB; Helfant RH Am J Physiol; 1988 Aug; 255(2 Pt 2):H301-10. PubMed ID: 3407791 [TBL] [Abstract][Full Text] [Related]
3. The effect of changes in afterload on systolic bulging. Noma S; Askenase AD; Agarwal JB; Helfant RH Circulation; 1988 Jan; 77(1):221-6. PubMed ID: 3335069 [TBL] [Abstract][Full Text] [Related]
4. Differential effects of Renografin-76 on the ischemic and nonischemic myocardium. Yamazaki H; Banka VS; Bodenheimer MM; Hattori S; Agarwal JB; Helfant RH Am J Cardiol; 1981 Mar; 47(3):597-602. PubMed ID: 6781323 [TBL] [Abstract][Full Text] [Related]
5. Differential hemodynamic effects of Hypaque-76 and Renografin-76 during coronary angiography: the role of calcium-binding additives. Hwang MH; Murdock DK; Piao ZE; Gries WJ; Scanlon PJ Cathet Cardiovasc Diagn; 1988; 15(1):5-10. PubMed ID: 3136927 [TBL] [Abstract][Full Text] [Related]
6. The effects of high (sodium meglumine diatrizoate, Renografin-76) and low osmolar (sodium meglumine ioxaglate, Hexabrix) radiographic contrast media on diastolic function during left ventriculography in patients. Aguirre FV; Pedersen W; Castello R; Deligonul U; Gudipati C; Serota H; Labovitz AJ; Kern MJ Am Heart J; 1991 Mar; 121(3 Pt 1):848-57. PubMed ID: 2000752 [TBL] [Abstract][Full Text] [Related]
7. Regional myocardial hemodynamic and metabolic effects of ionic and nonionic contrast media in normal and ischemic states. Gerber KH; Higgins CB; Yuh YS; Koziol JA Circulation; 1982 Jun; 65(7):1307-14. PubMed ID: 7074792 [TBL] [Abstract][Full Text] [Related]
8. Effects of low osmolality contrast materials on coronary hemodynamics, myocardial function, and coronary sinus osmolality in normal and ischemic states. Deutsch AL; Gerber KH; Haigler FH; Higgins CB Invest Radiol; 1982; 17(3):284-91. PubMed ID: 7118517 [TBL] [Abstract][Full Text] [Related]
9. Effects of intracoronary administration of contrast materials on left ventricular function in the presence of severe coronary artery stenosis. Green CE; Higgins CB; Kelley MJ; Newell JD; Schmidt WS; Haigler F Cardiovasc Intervent Radiol; 1981; 4(2):110-6. PubMed ID: 7249015 [TBL] [Abstract][Full Text] [Related]
10. Effect of intracoronary injections of sonicated microbubbles on left ventricular contractility. Lang RM; Borow KM; Neumann A; Al-Sadir J; Feinstein SB Am J Cardiol; 1987 Jul; 60(1):166-71. PubMed ID: 3604933 [TBL] [Abstract][Full Text] [Related]
12. Hemodynamic abnormalities during coronary angiography: comparison of Hypaque-76, Hexabrix, and Omnipaque-350. Piao ZE; Murdock DK; Hwang MH; Raymond RM; Scanlon PJ Cathet Cardiovasc Diagn; 1989 Mar; 16(3):149-54. PubMed ID: 2920387 [TBL] [Abstract][Full Text] [Related]
13. Effects of a new nonionic and a conventional ionic contrast agent on coronary sinus ionized calcium and left ventricular hemodynamics in dogs. Bourdillon PD; Bettmann MA; McCracken S; Poole-Wilson PA; Grossman W J Am Coll Cardiol; 1985 Oct; 6(4):845-53. PubMed ID: 4031299 [TBL] [Abstract][Full Text] [Related]
14. Mechanisms of improving regional and global ventricular function by preload alterations during acute ischemia in the canine left ventricle. Lew WY; Ban-Hayashi E Circulation; 1985 Nov; 72(5):1125-34. PubMed ID: 4042300 [TBL] [Abstract][Full Text] [Related]
16. Inotropic effects of ionic contrast media: the role of calcium binding additives. Murdock DK; Walsh J; Euler DE; Kozeny G; Scanlon PJ Cathet Cardiovasc Diagn; 1984; 10(5):455-63. PubMed ID: 6440712 [TBL] [Abstract][Full Text] [Related]
17. Comparative hemodynamic effects of coronary vasodilators and contrast material on the normal and ischemic canine myocardium: determination of the optimal agent for clinical augmentation of coronary blood flow. Higgins CB; Bookstein JJ Invest Radiol; 1977; 12(4):299-306. PubMed ID: 407173 [TBL] [Abstract][Full Text] [Related]
18. Echocardiographic contrast agents: effect of microbubbles and carrier solutions on left ventricular contractility. Lang RM; Borow KM; Neumann A; Feinstein SB J Am Coll Cardiol; 1987 Apr; 9(4):910-9. PubMed ID: 3558990 [TBL] [Abstract][Full Text] [Related]
19. Coronary angiography during acute myocardial infarction in dogs. A comparison of the hemodynamic effects of ionic and nonionic contrast media. Piao ZE; Murdock DK; Hwang MH; Gries W; Raymond RM; Scanlon PJ Chin Med J (Engl); 1988 Nov; 101(11):828-32. PubMed ID: 3150724 [No Abstract] [Full Text] [Related]
20. The haemodynamic effects of left ventriculography in coronary artery disease and mitral valve disease: a comparison of high and low osmolality contrast media. Fraser AG; Culling W; Singh H; Ruttley MS; Newcombe RG Eur Heart J; 1984 Sep; 5(9):727-34. PubMed ID: 6389137 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]