These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

145 related articles for article (PubMed ID: 31957636)

  • 1. Methods for Calibration of Specimen Temperature During
    Gaulandris F; Simonsen SB; Wagner JB; Mølhave K; Muto S; Kuhn LT
    Microsc Microanal; 2020 Feb; 26(1):3-17. PubMed ID: 31957636
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A MEMS-based heating holder for the direct imaging of simultaneous in-situ heating and biasing experiments in scanning/transmission electron microscopes.
    Mele L; Konings S; Dona P; Evertz F; Mitterbauer C; Faber P; Schampers R; Jinschek JR
    Microsc Res Tech; 2016 Apr; 79(4):239-50. PubMed ID: 26818213
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Temperature Calibration for In Situ Environmental Transmission Electron Microscopy Experiments.
    Winterstein JP; Lin PA; Sharma R
    Microsc Microanal; 2015 Dec; 21(6):1622-1628. PubMed ID: 26441334
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Temperature calibration of TEM specimen heating holders by isothermal sublimation of silver nanocubes.
    Vijayan S; Aindow M
    Ultramicroscopy; 2019 Jan; 196():142-153. PubMed ID: 30391803
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Focused Ion Beam Preparation of Specimens for Micro-Electro-Mechanical System-based Transmission Electron Microscopy Heating Experiments.
    Vijayan S; Jinschek JR; Kujawa S; Greiser J; Aindow M
    Microsc Microanal; 2017 Aug; 23(4):708-716. PubMed ID: 28578727
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Novel MEMS-based gas-cell/heating specimen holder provides advanced imaging capabilities for in situ reaction studies.
    Allard LF; Overbury SH; Bigelow WC; Katz MB; Nackashi DP; Damiano J
    Microsc Microanal; 2012 Aug; 18(4):656-66. PubMed ID: 22835379
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Quantification of extreme thermal gradients during in situ transmission electron microscope heating experiments.
    Vijayan S; Wang R; Kong Z; Jinschek JR
    Microsc Res Tech; 2022 Apr; 85(4):1527-1537. PubMed ID: 34897877
    [TBL] [Abstract][Full Text] [Related]  

  • 8. In-situ TEM study from the perspective of holders.
    Yaguchi T; Gabriel MLS; Hashimoto A; Howe JY
    Microscopy (Oxf); 2024 Apr; 73(2):117-132. PubMed ID: 37986584
    [TBL] [Abstract][Full Text] [Related]  

  • 9. An apparatus for plasma cleaning and storage of transmission electron microscopy specimens and specimen holders.
    Tang X; Gu LX; Li QL; Du ZM; Yang SH; Feng LJ; Li JH
    Microsc Res Tech; 2023 Feb; 86(2):198-207. PubMed ID: 36278407
    [TBL] [Abstract][Full Text] [Related]  

  • 10. An in situ heating TEM analysis method for an interface reaction.
    Tanigaki T; Ito K; Nagakubo Y; Asakawa T; Kanemura T
    J Electron Microsc (Tokyo); 2009 Oct; 58(5):281-7. PubMed ID: 19376815
    [TBL] [Abstract][Full Text] [Related]  

  • 11. In-situ heating-and-electron tomography for materials research: from 3D (in-situ 2D) to 4D (in-situ 3D).
    Hata S; Ihara S; Saito H; Murayama M
    Microscopy (Oxf); 2024 Apr; 73(2):133-144. PubMed ID: 38462986
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Local temperature measurement in TEM by parallel beam electron diffraction.
    Niekiel F; Kraschewski SM; Müller J; Butz B; Spiecker E
    Ultramicroscopy; 2017 May; 176():161-169. PubMed ID: 28049586
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Direct in situ thermometry: Variations in reciprocal-lattice vectors and challenges with the Debye-Waller effect.
    Cremons DR; Flannigan DJ
    Ultramicroscopy; 2016 Feb; 161():10-16. PubMed ID: 26624511
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Experimental set up for in situ transmission electron microscopy observations of chemical processes.
    Sharma R
    Micron; 2012 Nov; 43(11):1147-55. PubMed ID: 22622161
    [TBL] [Abstract][Full Text] [Related]  

  • 15. An in situ nanoindentation specimen holder for a high voltage transmission electron microscope.
    Wall MA; Dahmen U
    Microsc Res Tech; 1998 Aug; 42(4):248-54. PubMed ID: 9779829
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Development of a gas environmental heating specimen holder system using differential pumping.
    Hashimoto A; Han Y; Akimoto H; Hozumi R; Takeguchi M
    Microscopy (Oxf); 2021 Nov; 70(6):545-549. PubMed ID: 34046671
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Development of 2000 K Class High Temperature In Situ Transmission Electron Microscopy of Nanostructured Materials via Resistive Heating.
    Terasawa TO; Kikuchi S; Tezura M; Kizuka T
    J Nanosci Nanotechnol; 2017 Apr; 17(4):2848-851. PubMed ID: 29668196
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Quantifying Real-Time Sample Temperature Under the Gas Environment in the Transmission Electron Microscope Using a Novel MEMS Heater.
    Li M; Xie DG; Zhang XX; Yang JC; Shan ZW
    Microsc Microanal; 2021 Aug; 27(4):758-766. PubMed ID: 34018478
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Perspective and prospects of in situ transmission/scanning transmission electron microscopy.
    Sharma R; Yang WD
    Microscopy (Oxf); 2024 Apr; 73(2):79-100. PubMed ID: 38006307
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Importance and Challenges of Electrochemical in Situ Liquid Cell Electron Microscopy for Energy Conversion Research.
    Hodnik N; Dehm G; Mayrhofer KJ
    Acc Chem Res; 2016 Sep; 49(9):2015-22. PubMed ID: 27541965
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.