These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

130 related articles for article (PubMed ID: 31964560)

  • 1. Image-guided pedicle screws using intraoperative cone-beam CT and navigation. A cost-effectiveness study.
    Lee YC; Lee R
    J Clin Neurosci; 2020 Feb; 72():68-71. PubMed ID: 31964560
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Economic evaluation comparing intraoperative cone beam CT-based navigation and conventional fluoroscopy for the placement of spinal pedicle screws: a patient-level data cost-effectiveness analysis.
    Dea N; Fisher CG; Batke J; Strelzow J; Mendelsohn D; Paquette SJ; Kwon BK; Boyd MD; Dvorak MF; Street JT
    Spine J; 2016 Jan; 16(1):23-31. PubMed ID: 26456854
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Intraoperative Computed Tomography-Guided Navigation for Pediatric Spine Patients Reduced Return to Operating Room for Screw Malposition Compared With Freehand/Fluoroscopic Techniques.
    Baky FJ; Milbrandt T; Echternacht S; Stans AA; Shaughnessy WJ; Larson AN
    Spine Deform; 2019 Jul; 7(4):577-581. PubMed ID: 31202374
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A novel technique of cervical pedicle screw placement with a pilot screw under the guidance of intraoperative 3D imaging from C-arm cone-beam CT without navigation for safe and accurate insertion.
    Takahata M; Yamada K; Akira I; Endo T; Sudo H; Yokoyama H; Iwasaki N
    Eur Spine J; 2018 Nov; 27(11):2754-2762. PubMed ID: 30039255
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Economic study: a cost-effectiveness analysis of an intraoperative compared with a preoperative image-guided system in lumbar pedicle screw fixation in patients with degenerative spondylolisthesis.
    Costa F; Porazzi E; Restelli U; Foglia E; Cardia A; Ortolina A; Tomei M; Fornari M; Banfi G
    Spine J; 2014 Aug; 14(8):1790-6. PubMed ID: 24184651
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Retrospective Review of Revision Surgery After Image-guided Instrumented Spinal Surgery Compared With Traditional Instrumented Spinal Surgery.
    Towner JE; Li YI; Singla A; Moquin R; Li YM
    Clin Spine Surg; 2020 Aug; 33(7):E317-E321. PubMed ID: 32049676
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of open and percutaneous lumbar pedicle screw revision rate using 3-D image guidance and intraoperative CT.
    Santos ER; Sembrano JN; Yson SC; Polly DW
    Orthopedics; 2015 Feb; 38(2):e129-34. PubMed ID: 25665118
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Pediatric pedicle screw placement using intraoperative computed tomography and 3-dimensional image-guided navigation.
    Larson AN; Santos ER; Polly DW; Ledonio CG; Sembrano JN; Mielke CH; Guidera KJ
    Spine (Phila Pa 1976); 2012 Feb; 37(3):E188-94. PubMed ID: 21738101
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Intraoperative CT Scan Verification of Pedicle Screw Placement in AIS to Prevent Malpositioned Screws: Safety Benefit and Cost.
    Bauer JM; Moore JA; Rangarajan R; Gibbs BS; Yorgova PK; Neiss GI; Rogers K; Gabos PG; Shah SA
    Spine Deform; 2018; 6(6):662-668. PubMed ID: 30348341
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Risk-benefit analysis of navigation techniques for vertebral transpedicular instrumentation: a prospective study.
    Noriega DC; Hernández-Ramajo R; Rodríguez-Monsalve Milano F; Sanchez-Lite I; Toribio B; Ardura F; Torres R; Corredera R; Kruger A
    Spine J; 2017 Jan; 17(1):70-75. PubMed ID: 27503262
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Use of the Airo mobile intraoperative CT system versus the O-arm for transpedicular screw fixation in the thoracic and lumbar spine: a retrospective cohort study of 263 patients.
    Scarone P; Vincenzo G; Distefano D; Del Grande F; Cianfoni A; Presilla S; Reinert M
    J Neurosurg Spine; 2018 Oct; 29(4):397-406. PubMed ID: 29979141
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Accuracy of Pedicle Screw Placement in Children 10 Years or Younger Using Navigation and Intraoperative CT.
    Luo TD; Polly DW; Ledonio CG; Wetjen NM; Larson AN
    Clin Spine Surg; 2016 Apr; 29(3):E135-8. PubMed ID: 27007788
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The accuracy of navigation and 3D image-guided placement for the placement of pedicle screws in congenital spine deformity.
    Larson AN; Polly DW; Guidera KJ; Mielke CH; Santos ER; Ledonio CG; Sembrano JN
    J Pediatr Orthop; 2012 Sep; 32(6):e23-9. PubMed ID: 22892631
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Accuracy and revision rate of intraoperative computed tomography point-to-point navigation for lateral mass and pedicle screw placement: 11-year single-center experience in 1054 patients.
    Ishak B; Younsi A; Wieckhusen C; Slonczewski P; Unterberg AW; Kiening KL
    Neurosurg Rev; 2019 Dec; 42(4):895-905. PubMed ID: 30569212
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Intraoperative computed tomography image-guided navigation for posterior thoracolumbar spinal instrumentation in spinal deformity surgery.
    Tormenti MJ; Kostov DB; Gardner PA; Kanter AS; Spiro RM; Okonkwo DO
    Neurosurg Focus; 2010 Mar; 28(3):E11. PubMed ID: 20192656
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Navigated percutaneous versus open pedicle screw implantation using intraoperative CT and robotic cone-beam CT imaging.
    Tkatschenko D; Kendlbacher P; Czabanka M; Bohner G; Vajkoczy P; Hecht N
    Eur Spine J; 2020 Apr; 29(4):803-812. PubMed ID: 31820094
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Revision Rate of Misplaced Pedicle Screws of the Thoracolumbar Spine-Comparison of Three-Dimensional Fluoroscopy Navigation with Freehand Placement: A Systematic Analysis and Review of the Literature.
    Fichtner J; Hofmann N; Rienmüller A; Buchmann N; Gempt J; Kirschke JS; Ringel F; Meyer B; Ryang YM
    World Neurosurg; 2018 Jan; 109():e24-e32. PubMed ID: 28951183
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Increased Radiation but No Benefits in Pedicle Screw Accuracy With Navigation versus a Freehand Technique in Scoliosis Surgery.
    Urbanski W; Jurasz W; Wolanczyk M; Kulej M; Morasiewicz P; Dragan SL; Zaluski R; Miekisiak G; Dragan SF
    Clin Orthop Relat Res; 2018 May; 476(5):1020-1027. PubMed ID: 29432262
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Thoracolumbar instrumentation with CT-guided navigation (O-arm) in 270 consecutive patients: accuracy rates and lessons learned.
    Rivkin MA; Yocom SS
    Neurosurg Focus; 2014 Mar; 36(3):E7. PubMed ID: 24580008
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Safety and Accuracy of Freehand Pedicle Screw Placement and the Role of Intraoperative O-Arm: A Single-Institution Experience.
    Alomari S; Lubelski D; Lehner K; Tang A; Wolinsky JP; Theodore N; Sciubba DM; Larry Lo SF; Belzberg A; Weingart J; Witham T; Gokaslan ZL; Bydon A
    Spine (Phila Pa 1976); 2023 Feb; 48(3):180-188. PubMed ID: 36190990
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.