These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

130 related articles for article (PubMed ID: 31964560)

  • 21. Safety and Efficacy of Reconstruction of Complex Cervical Spine Pathology Using Pedicle Screws Inserted with Stealth Navigation and 3D Image-Guided (O-Arm) Technology.
    Theologis AA; Burch S
    Spine (Phila Pa 1976); 2015 Sep; 40(18):1397-406. PubMed ID: 26426710
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Intraoperative image guidance compared with free-hand methods in adolescent idiopathic scoliosis posterior spinal surgery: a systematic review on screw-related complications and breach rates.
    Chan A; Parent E; Narvacan K; San C; Lou E
    Spine J; 2017 Sep; 17(9):1215-1229. PubMed ID: 28428081
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Early experience of placing image-guided minimally invasive pedicle screws without K-wires or bone-anchored trackers.
    Malham GM; Parker RM
    J Neurosurg Spine; 2018 Apr; 28(4):357-363. PubMed ID: 29372857
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Learning curve of 3D fluoroscopy image-guided pedicle screw placement in the thoracolumbar spine.
    Ryang YM; Villard J; Obermüller T; Friedrich B; Wolf P; Gempt J; Ringel F; Meyer B
    Spine J; 2015 Mar; 15(3):467-76. PubMed ID: 25315133
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Clinical and Radiologic Outcomes of Thoracolumbar Fusions Using Intraoperative CT Guidance and Stereotactic Navigation in a Spinal Trauma Population: An Analysis of 58 Patients.
    Domino JS; Smith KA; Arnold PM
    Clin Spine Surg; 2021 Mar; 34(2):E80-E85. PubMed ID: 33633063
    [TBL] [Abstract][Full Text] [Related]  

  • 26. A prospective multicenter registry on the accuracy of pedicle screw placement in the thoracic, lumbar, and sacral levels with the use of the O-arm imaging system and StealthStation Navigation.
    Van de Kelft E; Costa F; Van der Planken D; Schils F
    Spine (Phila Pa 1976); 2012 Dec; 37(25):E1580-7. PubMed ID: 23196967
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Percutaneous pedicle screw placement under single dimensional fluoroscopy with a designed pedicle finder-a technical note and case series.
    Tsuang FY; Chen CH; Kuo YJ; Tseng WL; Chen YS; Lin CJ; Liao CJ; Lin FH; Chiang CJ
    Spine J; 2017 Sep; 17(9):1373-1380. PubMed ID: 28645672
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Comparison of cranial facet joint violation rates between open and percutaneous pedicle screw placement using intraoperative 3-D CT (O-arm) computer navigation.
    Yson SC; Sembrano JN; Sanders PC; Santos ER; Ledonio CG; Polly DW
    Spine (Phila Pa 1976); 2013 Feb; 38(4):E251-8. PubMed ID: 23197012
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Electromyography stimulation compared with intraoperative O-arm imaging for evaluating pedicle screw breaches in lumbar spine surgery: a prospective analysis of 1006 screws in 164 patients.
    Ravindra VM; Kalra RR; Dailey AT
    Spine J; 2019 Feb; 19(2):206-211. PubMed ID: 29960110
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Development of a new technique for pedicle screw and Magerl screw insertion using a 3-dimensional image guide.
    Kawaguchi Y; Nakano M; Yasuda T; Seki S; Hori T; Kimura T
    Spine (Phila Pa 1976); 2012 Nov; 37(23):1983-8. PubMed ID: 22531473
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Surgical safety of cervical pedicle screw placement with computer navigation system.
    Shimokawa N; Takami T
    Neurosurg Rev; 2017 Apr; 40(2):251-258. PubMed ID: 27245606
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Cervical pedicle screw instrumentation is more reliable with O-arm-based 3D navigation: analysis of cervical pedicle screw placement accuracy with O-arm-based 3D navigation.
    Chachan S; Bin Abd Razak HR; Loo WL; Allen JC; Shree Kumar D
    Eur Spine J; 2018 Nov; 27(11):2729-2736. PubMed ID: 29651593
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Workflow and performance of intraoperative CT, cone-beam CT, and robotic cone-beam CT for spinal navigation in 503 consecutive patients.
    Kendlbacher P; Tkatschenko D; Czabanka M; Bayerl S; Bohner G; Woitzik J; Vajkoczy P; Hecht N
    Neurosurg Focus; 2022 Jan; 52(1):E7. PubMed ID: 34973677
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Safety and accuracy of freehand versus navigated C2 pars or pedicle screw placement.
    Hlubek RJ; Bohl MA; Cole TS; Morgan CD; Xu DS; Chang SW; Turner JD; Kakarla UK
    Spine J; 2018 Aug; 18(8):1374-1381. PubMed ID: 29253631
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Feasibility of mixed reality-based intraoperative three-dimensional image-guided navigation for atlanto-axial pedicle screw placement.
    Wu X; Liu R; Xu S; Yang C; Yang S; Shao Z; Li S; Ye Z
    Proc Inst Mech Eng H; 2019 Dec; 233(12):1310-1317. PubMed ID: 31617820
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Prospective Comparison Study Between the Fluoroscopy-guided and Navigation Coupled With O-arm-guided Pedicle Screw Placement in the Thoracic and Lumbosacral Spines.
    Shin MH; Hur JW; Ryu KS; Park CK
    J Spinal Disord Tech; 2015 Jul; 28(6):E347-51. PubMed ID: 23563342
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Percutaneous pedicle screw placements: accuracy and rates of cranial facet joint violation using conventional fluoroscopy compared with intraoperative three-dimensional computed tomography computer navigation.
    Ohba T; Ebata S; Fujita K; Sato H; Haro H
    Eur Spine J; 2016 Jun; 25(6):1775-80. PubMed ID: 26957097
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Incidence and risk factors for the misplacement of pedicle screws in scoliosis surgery assisted by O-arm navigation-analysis of a large series of one thousand, one hundred and forty five screws.
    Jin M; Liu Z; Qiu Y; Yan H; Han X; Zhu Z
    Int Orthop; 2017 Apr; 41(4):773-780. PubMed ID: 27999927
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Spinal intraoperative three-dimensional navigation: correlation between clinical and absolute engineering accuracy.
    Guha D; Jakubovic R; Gupta S; Alotaibi NM; Cadotte D; da Costa LB; George R; Heyn C; Howard P; Kapadia A; Klostranec JM; Phan N; Tan G; Mainprize TG; Yee A; Yang VX
    Spine J; 2017 Apr; 17(4):489-498. PubMed ID: 27777052
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Clinical outcomes following spinal fusion using an intraoperative computed tomographic 3D imaging system.
    Xiao R; Miller JA; Sabharwal NC; Lubelski D; Alentado VJ; Healy AT; Mroz TE; Benzel EC
    J Neurosurg Spine; 2017 May; 26(5):628-637. PubMed ID: 28291408
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.