These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

63 related articles for article (PubMed ID: 3196528)

  • 1. Flow visualization in an artificial heart using diffuse and planar laser lighting.
    Mussivand T; Navarro R; Chen JF; Braun J; Harasaki H; Kiraly R; Batur C; McMillin C; Nosé Y
    ASAIO Trans; 1988; 34(3):317-21. PubMed ID: 3196528
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Flow visualization in the Baylor total artificial heart.
    Orime Y; Takatani S; Tasai K; Ohara Y; Naito K; Mizuguchi K; Makinouchi K; Rosenow SE; Glueck J; Noon GP
    Artif Organs; 1994 Jan; 18(1):73-9. PubMed ID: 8141661
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Flow pattern analysis of the Baylor total artificial heart.
    Meier D; Wernicke JT; Orime Y; Takatani S; Tasai K; Damm G; Naito K; Mizuguchi K; Makinouchi K; Glueck J
    Artif Organs; 1994 Dec; 18(12):923-32. PubMed ID: 7887830
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Diaphragm motion affects flow patterns in an artificial heart.
    Hochareon P; Manning KB; Fontaine AA; Deutsch S; Tarbell JM
    Artif Organs; 2003 Dec; 27(12):1102-9. PubMed ID: 14678424
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The Baylor total artificial heart. Flow visualization studies.
    Orime Y; Takatani S; Tasai K; Ohara Y; Naito K; Mizuguchi K; Meier D; Wernicke JT; Damm G; Glueck J
    ASAIO J; 1994; 40(3):M499-505. PubMed ID: 8555566
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Characterization and optimization of the flow pattern inside a diaphragm blood pump based on flow visualization techniques.
    Nakata M; Masuzawa T; Tatsumi E; Taenaka Y; Nishimura T; Tsukiya T; Takano H; Tsuchimoto K; Ohba K
    ASAIO J; 1998; 44(5):M714-8. PubMed ID: 9804529
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Improvement on the auxiliary total artificial heart (ATAH) left chamber design.
    Andrade A; Fonseca J; Legendre D; Nicolosi D; Biscegli J; Pinotti M; Ohashi Y; Nosé Y
    Artif Organs; 2003 May; 27(5):452-6. PubMed ID: 12752207
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Design of pusher-plate-type left ventricular assist device based on mechanical analyses.
    Hayashi K; Nakamura T; Takano H; Umezu M; Taenaka Y; Matsuda T
    Artif Organs; 1984 May; 8(2):204-14. PubMed ID: 6732549
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Particle-image velocimetry study of a pediatric ventricular assist device.
    Ferrara E; Muramatsu M; Christensen KT; Cestari IA
    J Biomech Eng; 2010 Jul; 132(7):071004. PubMed ID: 20590282
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Flow visualization studies to improve the spiral pump design.
    Andrade A; Biscegli J; Sousa JE; Ohashi Y; Nosé Y
    Artif Organs; 1997 Jul; 21(7):680-5. PubMed ID: 9212938
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Determination of cardiac output of the artificial heart from the drive air flow.
    Hanzelka P; Vasků J; Urbánek P; Vasků J; Urbánek E
    Artif Organs; 1979 Aug; 3(3):277-8. PubMed ID: 161167
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Fluorescent image tracking velocimetry of the Nimbus AxiPump.
    Kerrigan JP; Shaffer FD; Maher TR; Dennis TJ; Borovetz HS; Antaki JF
    ASAIO J; 1993; 39(3):M639-43. PubMed ID: 8268616
    [TBL] [Abstract][Full Text] [Related]  

  • 13. In vitro velocity and turbulence measurements in the vicinity of three new mechanical aortic heart valve prostheses: Björk-Shiley Monostrut, Omni-Carbon, and Duromedics.
    Yoganathan AP; Sung HW; Woo YR; Jones M
    J Thorac Cardiovasc Surg; 1988 May; 95(5):929-39. PubMed ID: 3361941
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Simultaneous measurement of blood and myocardial velocity in the rat heart by phase contrast MRI using sparse q-space sampling.
    Wise RG; Al-Shafei AI; Carpenter TA; Hall LD; Huang CL
    J Magn Reson Imaging; 2005 Nov; 22(5):614-27. PubMed ID: 16193471
    [TBL] [Abstract][Full Text] [Related]  

  • 15. An in vitro investigation of the retrograde flow fields of two bileaflet mechanical heart valves.
    Ellis JT; Healy TM; Fontaine AA; Weston MW; Jarret CA; Saxena R; Yoganathan AP
    J Heart Valve Dis; 1996 Nov; 5(6):600-6. PubMed ID: 8953437
    [TBL] [Abstract][Full Text] [Related]  

  • 16. In vitro pulsatile flow measurements in the vicinity of mechanical heart valves in the mitral flow chamber.
    Woo YR; Yoganathan AP
    Life Support Syst; 1986; 4(2):115-39. PubMed ID: 2943945
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Application of a new nuclear scintigraphy camera to evaluate flow and mechanical pumping of artificial hearts.
    Christensen CW; Smith LM; Gao H; Grenier RP; Schmidt DH
    ASAIO Trans; 1991; 37(3):M503-5. PubMed ID: 1751253
    [TBL] [Abstract][Full Text] [Related]  

  • 18. In vitro pulsatile flow velocity and turbulent shear stress measurements in the vicinity of mechanical aortic heart valve prostheses.
    Woo YR; Yoganathan AP
    Life Support Syst; 1985; 3(4):283-312. PubMed ID: 4068753
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Velocity measurements and flow patterns within the hinge region of a Medtronic Parallel bileaflet mechanical valve with clear housing.
    Ellis JT; Healy TM; Fontaine AA; Saxena R; Yoganathan AP
    J Heart Valve Dis; 1996 Nov; 5(6):591-9. PubMed ID: 8953436
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Flow pattern and shear stress distribution of distal end-to-side anastomoses. A comparison of the instantaneous velocity fields obtained by particle image velocimetry.
    Heise M; Schmidt S; Krüger U; Rückert R; Rösler S; Neuhaus P; Settmacher U
    J Biomech; 2004 Jul; 37(7):1043-51. PubMed ID: 15165874
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.