These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
131 related articles for article (PubMed ID: 3196553)
1. Hemolysis. A comparative study of four nonpulsatile pumps. Oku T; Harasaki H; Smith W; Nosé Y ASAIO Trans; 1988; 34(3):500-4. PubMed ID: 3196553 [TBL] [Abstract][Full Text] [Related]
2. The effects of pressure and flow on hemolysis caused by Bio-Medicus centrifugal pumps and roller pumps. Guidelines for choosing a blood pump. Tamari Y; Lee-Sensiba K; Leonard EF; Parnell V; Tortolani AJ J Thorac Cardiovasc Surg; 1993 Dec; 106(6):997-1007. PubMed ID: 8246582 [TBL] [Abstract][Full Text] [Related]
3. Pump-induced haemolysis: a comparison of short-term ventricular assist devices. Bennett M; Horton S; Thuys C; Augustin S; Rosenberg M; Brizard C Perfusion; 2004 Mar; 19(2):107-11. PubMed ID: 15162925 [TBL] [Abstract][Full Text] [Related]
4. An under-occluded roller pump is less hemolytic than a centrifugal pump. Rawn DJ; Harris HK; Riley JB; Yoda DN; Blackwell MM J Extra Corpor Technol; 1997 Mar; 29(1):15-8. PubMed ID: 10166360 [TBL] [Abstract][Full Text] [Related]
5. Laboratory Evaluation of Hemolysis and Systemic Inflammatory Response in Neonatal Nonpulsatile and Pulsatile Extracorporeal Life Support Systems. Wang S; Krawiec C; Patel S; Kunselman AR; Song J; Lei F; Baer LD; Ündar A Artif Organs; 2015 Sep; 39(9):774-81. PubMed ID: 25940752 [TBL] [Abstract][Full Text] [Related]
6. Effects of Pulsatile Control Algorithms for Diagonal Pump on Hemodynamic Performance and Hemolysis. Wang S; Force M; Moroi MK; Patel S; Kunselman AR; Ündar A Artif Organs; 2019 Jan; 43(1):60-75. PubMed ID: 30374991 [TBL] [Abstract][Full Text] [Related]
7. Comparative hemolysis study of clinically available centrifugal pumps. Naito K; Suenaga E; Cao ZL; Suda H; Ueno T; Natsuaki M; Itoh T Artif Organs; 1996 Jun; 20(6):560-3. PubMed ID: 8817955 [TBL] [Abstract][Full Text] [Related]
8. Experience in reducing the hemolysis of an impeller assist heart. Qian KX ASAIO Trans; 1989; 35(1):46-53. PubMed ID: 2730808 [TBL] [Abstract][Full Text] [Related]
9. Hemodialysis using a valveless pulsatile blood pump. Lee K; Mun CH; Lee SR; Min BG; Yoo KJ; Park YW; Won YS ASAIO J; 2008; 54(2):191-6. PubMed ID: 18356654 [TBL] [Abstract][Full Text] [Related]
10. The need for standardizing the index of hemolysis. Naito K; Mizuguchi K; Nosé Y Artif Organs; 1994 Jan; 18(1):7-10. PubMed ID: 8141660 [TBL] [Abstract][Full Text] [Related]
11. Hemolytic characteristics of three commercially available centrifugal blood pumps. Lawson DS; Ing R; Cheifetz IM; Walczak R; Craig D; Schulman S; Kern F; Shearer IR; Lodge A; Jaggers J Pediatr Crit Care Med; 2005 Sep; 6(5):573-7. PubMed ID: 16148820 [TBL] [Abstract][Full Text] [Related]
12. Comparison of centrifugal and roller pump hemolysis rates at low flow. Moon YS; Ohtsubo S; Gomez MR; Moon JK; Nosé Y Artif Organs; 1996 Jun; 20(6):579-81. PubMed ID: 8817960 [TBL] [Abstract][Full Text] [Related]
13. Nonlinear Flow Rate Response to Pumping Frequency and Reduced Hemolysis in the Drastically Under-Occluded Pulsatile Roller Pump. Yap CH; Lai CQ; Loh IG; Ong TZ Artif Organs; 2017 Feb; 41(2):178-185. PubMed ID: 27653754 [TBL] [Abstract][Full Text] [Related]
14. Comparative Hemolysis Study of Clinically Available Centrifugal Pumps. Naito K; Suenaga E; Cao ZL; Suda H; Ueno T; Natsuaki M; Itoh T Artif Organs; 1996 May; 20(5):560-563. PubMed ID: 28868706 [TBL] [Abstract][Full Text] [Related]
15. An approach to reducing hemolysis in an axial-flow blood pump. Anai H; Nakatani T; Wakisaka Y; Araki K; Taenaka Y; Tatsumi E; Masuzawa T; Baba Y; Eya K; Toda K ASAIO J; 1995; 41(3):M771-4. PubMed ID: 8573911 [TBL] [Abstract][Full Text] [Related]
16. Blood trauma testing of CentriMag and RotaFlow centrifugal flow devices: a pilot study. Sobieski MA; Giridharan GA; Ising M; Koenig SC; Slaughter MS Artif Organs; 2012 Aug; 36(8):677-82. PubMed ID: 22882437 [TBL] [Abstract][Full Text] [Related]
18. A hemodynamic evaluation of the Levitronix Pedivas centrifugal pump and Jostra Hl-20 roller pump under pulsatile and nonpulsatile perfusion in an infant CPB model. Ressler N; Rider AR; Kunselman AR; Richardson JS; Dasse KA; Wang S; Undar A ASAIO J; 2009; 55(1):106-10. PubMed ID: 19092661 [TBL] [Abstract][Full Text] [Related]
19. The spindle pump. Development of a nonpulsatile blood pump for assisted circulation. Hager J; Brandstaetter F; Koller I; Unger F ASAIO Trans; 1989; 35(3):471-4. PubMed ID: 2597510 [TBL] [Abstract][Full Text] [Related]
20. The effect on hemolysis of the raceway profile of roller pumps used in cardiopulmonary bypass. Vieira FU; Costa ET; Vieira RW; Antunes N; Petrucci O; de Oliveira PP ASAIO J; 2012; 58(1):40-5. PubMed ID: 21266907 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]