147 related articles for article (PubMed ID: 31967027)
1. PSEUDOHYPONATREMIA IN THE SETTING OF HYPERCHOLESTEROLEMIA.
El Hage L; Reineks E; Nasr C
AACE Clin Case Rep; 2019; 5(2):e172-e174. PubMed ID: 31967027
[TBL] [Abstract][Full Text] [Related]
2. Preventing pseudohyponatremia: Intralipid®-based lipemia cutoffs for sodium are inappropriate.
Koch CD; Vera MA; Messina J; Price N; Durant TJS; El-Khoury JM
Clin Chim Acta; 2021 Sep; 520():63-66. PubMed ID: 34077753
[TBL] [Abstract][Full Text] [Related]
3. Extreme hypercholesterolemia presenting with pseudohyponatremia - a case report and review of the literature.
Hussain I; Ahmad Z; Garg A
J Clin Lipidol; 2015; 9(2):260-4. PubMed ID: 25911084
[TBL] [Abstract][Full Text] [Related]
4. A new method for determining plasma water content: application in pseudohyponatremia.
Nguyen MK; Ornekian V; Butch AW; Kurtz I
Am J Physiol Renal Physiol; 2007 May; 292(5):F1652-6. PubMed ID: 17299138
[TBL] [Abstract][Full Text] [Related]
5. Pseudohyponatremia: Mechanism, Diagnosis, Clinical Associations and Management.
Aziz F; Sam R; Lew SQ; Massie L; Misra M; Roumelioti ME; Argyropoulos CP; Ing TS; Tzamaloukas AH
J Clin Med; 2023 Jun; 12(12):. PubMed ID: 37373769
[TBL] [Abstract][Full Text] [Related]
6. Prevalence of Clinically Significant Differences in Sodium Measurements Due to Abnormal Protein Concentrations Using an Indirect Ion-Selective Electrode Method.
Katrangi W; Baumann NA; Nett RC; Karon BS; Block DR
J Appl Lab Med; 2019 Nov; 4(3):427-432. PubMed ID: 31659081
[TBL] [Abstract][Full Text] [Related]
7. Resolving Pseudohyponatremia: Validation of Plasma Sodium on Radiometer ABL800 Blood Gas Analyzers for Immediate Reflex Testing.
Vera MA; Sutphin A; Hansen L; El-Khoury JM
Lab Med; 2022 Sep; 53(5):e105-e108. PubMed ID: 35015890
[TBL] [Abstract][Full Text] [Related]
8. Use of therapeutic plasma exchange to remove lipoprotein X in a patient with vanishing bile duct syndrome presenting with cholestasis, pseudohyponatremia, and hypercholesterolemia: A case report and review of literature.
Jung Y; Nelson HA; Lin DM
J Clin Apher; 2024 Feb; 39(1):e22105. PubMed ID: 38334173
[TBL] [Abstract][Full Text] [Related]
9. A case of pulmonary hyalinizing granuloma characterized by pseudohyponatremia due to hyperproteinemia.
Yamauchi M; Kamejima S; Yamamoto I; Ohkido I; Araya J; Yokoo T
Respir Med Case Rep; 2023; 43():101854. PubMed ID: 37124054
[TBL] [Abstract][Full Text] [Related]
10. [Direct and indirect ion selective electrodes methods: the differences specified through a case of Waldenström's macroglobulinemia].
Zelmat MS
Ann Biol Clin (Paris); 2015; 73(3):345-52. PubMed ID: 26069070
[TBL] [Abstract][Full Text] [Related]
11. Pseudohyponatremia Leading to a Fatal Outcome in a Patient With Familial Hypertriglyceridemia.
Dawson A; Kanukuntla A; Kata P; Ali R; Cheriyath P
Cureus; 2021 Aug; 13(8):e17066. PubMed ID: 34522544
[TBL] [Abstract][Full Text] [Related]
12. Evaluation of the analytical performance of a portable ion-selective electrode meter for measuring whole-blood, plasma, milk, abomasal-fluid, and urine sodium concentrations in cattle.
Megahed AA; Hiew M; Grünberg W; Trefz FM; Constable PD
J Dairy Sci; 2019 Aug; 102(8):7435-7444. PubMed ID: 31202658
[TBL] [Abstract][Full Text] [Related]
13. Pseudohyponatremia Secondary to Hypercholesterolemia in the Setting of Intrahepatic Cholestasis due to Metastatic Liver Disease: A Case Report and Review of the Literature.
Pourafkari L; Cavalieri C; Yavari SK; Nader ND
Acta Med Acad; 2022 Aug; 51(2):128-131. PubMed ID: 36318005
[TBL] [Abstract][Full Text] [Related]
14. The challenges of sodium measurements: indirect versus direct ion-selective method.
Refardt J; Sailer CO; Chifu I; Winzeler B; Schnyder I; Fassnacht M; Fenske W; Christ-Crain M
Eur J Endocrinol; 2019 Aug; 181(2):193-199. PubMed ID: 31167167
[TBL] [Abstract][Full Text] [Related]
15. Pseudohyponatremia in acute liver disease.
Vo H; Gosmanov AR; Garcia-Rosell M; Wall BM
Am J Med Sci; 2013 Jan; 345(1):62-4. PubMed ID: 23232812
[TBL] [Abstract][Full Text] [Related]
16. Effect of Hypoproteinemia on Electrolyte Measurement by Direct and Indirect Ion Selective Electrode Methods.
Gohel M; Makadia JS; Chakrabarti C
J Lab Physicians; 2021 Jun; 13(2):144-147. PubMed ID: 34483560
[No Abstract] [Full Text] [Related]
17. Plasma sodium measurements by direct ion selective methods in laboratory and point of care may not be clinically interchangeable.
Weld BA; Morgan TJ; Presneill JJ; Weier S; Cowley D
J Clin Monit Comput; 2017 Oct; 31(5):1103-1109. PubMed ID: 27683272
[TBL] [Abstract][Full Text] [Related]
18. Effects of total plasma protein concentration on plasma sodium, potassium and chloride measurements by an indirect ion selective electrode measuring system.
Dimeski G; Barnett RJ
Crit Care Resusc; 2005 Mar; 7(1):12-5. PubMed ID: 16548813
[TBL] [Abstract][Full Text] [Related]
19. Pseudohyponatremia revisited: a modern-day pitfall.
Fortgens P; Pillay TS
Arch Pathol Lab Med; 2011 Apr; 135(4):516-9. PubMed ID: 21466372
[TBL] [Abstract][Full Text] [Related]
20. Pseudohyponatremia: does it matter in current clinical practice?
Kim GH
Electrolyte Blood Press; 2006 Nov; 4(2):77-82. PubMed ID: 24459491
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]