These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
183 related articles for article (PubMed ID: 31972382)
1. Outcomes of cochlear implantation in patients with incomplete partition type III. Sun J; Sun J Int J Pediatr Otorhinolaryngol; 2020 Apr; 131():109890. PubMed ID: 31972382 [TBL] [Abstract][Full Text] [Related]
2. Incomplete partition type III: A rare and difficult cochlear implant surgical indication. Sennaroğlu L; Bajin MD Auris Nasus Larynx; 2018 Feb; 45(1):26-32. PubMed ID: 28318810 [TBL] [Abstract][Full Text] [Related]
3. Cochlear implantation with round window insertion in children with otitis media with effusion. Sun JQ; Sun JW; Hou XY ORL J Otorhinolaryngol Relat Spec; 2014; 76(1):13-8. PubMed ID: 24577319 [TBL] [Abstract][Full Text] [Related]
4. Cochlear implantation requiring a retrofacial approach to the round window. Allen KP; Bartels LJ; Isaacson B Otol Neurotol; 2015 Mar; 36(3):e84-6. PubMed ID: 25502454 [TBL] [Abstract][Full Text] [Related]
5. Retrofacial approach to access the round window for cochlear implantation of malformed ears. Rizk H; O'Connell B; Stevens S; Meyer T Otol Neurotol; 2015 Mar; 36(3):e79-83. PubMed ID: 25594386 [TBL] [Abstract][Full Text] [Related]
6. Cochlear implantation outcomes with round window electrode insertion versus cochleostomy insertion. Elafandi H; Khalifa MA; Elguindy AS Int J Pediatr Otorhinolaryngol; 2020 Nov; 138():110272. PubMed ID: 32798831 [TBL] [Abstract][Full Text] [Related]
7. [Minimally invasive surgical techniques of cochlear implantation withround window pathways in young children]. Ma J; Ruan B; Mao ZY; Li SL; Gao YQ; Lin K; Zhang TS Lin Chuang Er Bi Yan Hou Tou Jing Wai Ke Za Zhi; 2016 Jun; 30(12):978-981. PubMed ID: 29771067 [No Abstract] [Full Text] [Related]
8. Radiologic Results and Hearing Preservation With a Straight Narrow Electrode via Round Window Versus Cochleostomy Approach at Initial Activation. Hassepass F; Aschendorff A; Bulla S; Arndt S; Maier W; Laszig R; Beck R Otol Neurotol; 2015 Jul; 36(6):993-1000. PubMed ID: 25675315 [TBL] [Abstract][Full Text] [Related]
9. Cochlear Implantation in Otosclerosis: Surgical and Auditory Outcomes With a Brief on Facial Nerve Stimulation. Vashishth A; Fulcheri A; Rossi G; Prasad SC; Caruso A; Sanna M Otol Neurotol; 2017 Oct; 38(9):e345-e353. PubMed ID: 28902803 [TBL] [Abstract][Full Text] [Related]
10. Round window membrane visibility related to success of hearing preservation in cochlear implantation. Jang JH; Choo OS; Kim H; Yi Park H; Choung YH Acta Otolaryngol; 2019 Jul; 139(7):618-624. PubMed ID: 31066597 [No Abstract] [Full Text] [Related]
11. Variations in electrode impedance during and after cochlear implantation: Round window versus extended round window insertions. Wang J; Sun J; Sun J; Chen J Int J Pediatr Otorhinolaryngol; 2017 Nov; 102():44-48. PubMed ID: 29106874 [TBL] [Abstract][Full Text] [Related]
12. A cool approach to reducing electrode-induced trauma: Localized therapeutic hypothermia conserves residual hearing in cochlear implantation. Tamames I; King C; Bas E; Dietrich WD; Telischi F; Rajguru SM Hear Res; 2016 Sep; 339():32-9. PubMed ID: 27260269 [TBL] [Abstract][Full Text] [Related]
13. Comparison of electrode position between round window and cochleostomy inserting approaches among young children: a cone-beam computed tomography study. Fan X; Xia M; Wang Z; Zhang H; Liu C; Wang N; Hou L; Li C; Xu A Acta Otolaryngol; 2018 Sep; 138(9):815-821. PubMed ID: 29936898 [TBL] [Abstract][Full Text] [Related]
14. Cochlear implantation and hearing preservation: Results in 21 consecutively operated patients using the round window approach. Erixon E; Köbler S; Rask-Andersen H Acta Otolaryngol; 2012 Sep; 132(9):923-31. PubMed ID: 22667762 [TBL] [Abstract][Full Text] [Related]
15. Cochlear Implantation Following Explorative Tympanotomy in Patients With Sudden Sensorineural Hearing Loss: Surgical Features and Audiological Outcomes. Rupp R; Hornung J; Balk M; Sievert M; Müller S; Hoppe U; Iro H; Gostian AO Ear Nose Throat J; 2023 Jun; 102(6):NP277-NP283. PubMed ID: 33848205 [TBL] [Abstract][Full Text] [Related]
16. Identification and revision of a displaced cochlear implant electrode in the internal auditory canal. Todt I; Rademacher G; Ernst A Cochlear Implants Int; 2013 Sep; 14(4):236-9. PubMed ID: 23510683 [TBL] [Abstract][Full Text] [Related]
17. Surgical techniques and outcomes of cochlear implantation in patients with radiographic findings consistent with X-linked deafness. Cosetti MK; Friedmann DR; Heman-Ackah SE; Perez R; Waltzman SB; Roland JT Int J Pediatr Otorhinolaryngol; 2015 Oct; 79(10):1689-93. PubMed ID: 26250436 [TBL] [Abstract][Full Text] [Related]
18. Landmarks for Proper Round Window Electrode Insertion in Cochlear Implantation. Fiky LE; Mostafa BE; Ibrahim SA; Teaima AA J Int Adv Otol; 2022 May; 18(3):210-213. PubMed ID: 35608488 [TBL] [Abstract][Full Text] [Related]
19. Cochlear implantation using a custom guide catheter in 14 patients with incomplete partition type III. Tian H; Wang L; Gao F; Liang W; Peng KA Clin Otolaryngol; 2018 Oct; 43(5):1379-1383. PubMed ID: 29788544 [No Abstract] [Full Text] [Related]
20. Congenital aplasia of the semicircular canals. Satar B; Mukherji SK; Telian SA Otol Neurotol; 2003 May; 24(3):437-46. PubMed ID: 12806296 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]