These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

140 related articles for article (PubMed ID: 31973944)

  • 1. Comparison of the performance between Frontier ASPECTS software and different levels of radiologists on assessing CT examinations of acute ischaemic stroke patients.
    Li L; Chen Y; Bao Y; Jia X; Wang Y; Zuo T; Zhu F
    Clin Radiol; 2020 May; 75(5):358-365. PubMed ID: 31973944
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Automated ASPECT rating: comparison between the Frontier ASPECT Score software and the Brainomix software.
    Goebel J; Stenzel E; Guberina N; Wanke I; Koehrmann M; Kleinschnitz C; Umutlu L; Forsting M; Moenninghoff C; Radbruch A
    Neuroradiology; 2018 Dec; 60(12):1267-1272. PubMed ID: 30219935
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Automated ASPECT scoring in acute ischemic stroke: comparison of three software tools.
    Hoelter P; Muehlen I; Goelitz P; Beuscher V; Schwab S; Doerfler A
    Neuroradiology; 2020 Oct; 62(10):1231-1238. PubMed ID: 32382795
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Automated ASPECTS in acute ischemic stroke: comparison of the overall scores and Hounsfield unit values of two software packages and radiologists with different levels of experience.
    Li X; Zhen Y; Liu H; Zeng W; Li Y; Liu L; Yang R
    Acta Radiol; 2023 Jan; 64(1):328-335. PubMed ID: 35118879
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Performance of e-ASPECTS software in comparison to that of stroke physicians on assessing CT scans of acute ischemic stroke patients.
    Herweh C; Ringleb PA; Rauch G; Gerry S; Behrens L; Möhlenbruch M; Gottorf R; Richter D; Schieber S; Nagel S
    Int J Stroke; 2016 Jun; 11(4):438-45. PubMed ID: 26880058
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Assistance from Automated ASPECTS Software Improves Reader Performance.
    Delio PR; Wong ML; Tsai JP; Hinson HE; McMenamy J; Le TQ; Prabhu D; Mann BS; Copeland K; Kwok K; Haerian H; Lansberg MJ; Heit JJ
    J Stroke Cerebrovasc Dis; 2021 Jul; 30(7):105829. PubMed ID: 33989968
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Interobserver agreement between senior radiology resident, neuroradiology fellow, and experienced neuroradiologist in the rating of Alberta Stroke Program Early Computed Tomography Score (ASPECTS).
    Kobkitsuksakul C; Tritanon O; Suraratdecha V
    Diagn Interv Radiol; 2018; 24(2):104-107. PubMed ID: 29467112
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Detection of early infarction signs with machine learning-based diagnosis by means of the Alberta Stroke Program Early CT score (ASPECTS) in the clinical routine.
    Guberina N; Dietrich U; Radbruch A; Goebel J; Deuschl C; Ringelstein A; Köhrmann M; Kleinschnitz C; Forsting M; Mönninghoff C
    Neuroradiology; 2018 Sep; 60(9):889-901. PubMed ID: 30066278
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Agreement and Accuracy of Ischemic Core Volume Evaluated by Three CT Perfusion Software Packages in Acute Ischemic Stroke.
    Liu QC; Jia ZY; Zhao LB; Cao YZ; Ma G; Shi HB; Liu S
    J Stroke Cerebrovasc Dis; 2021 Aug; 30(8):105872. PubMed ID: 34153591
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Impact of Encephalomalacia and White Matter Hyperintensities on ASPECTS in Patients With Acute Ischemic Stroke: Comparison of Automated and Radiologist-Derived Scores.
    Huang L; Liu Q; Lu X; Liu S; Cao C; Wang Z; Zhang X; Xia S
    AJR Am J Roentgenol; 2022 May; 218(5):878-887. PubMed ID: 34910537
    [No Abstract]   [Full Text] [Related]  

  • 11. Tilt-Corrected Region Boundaries May Enhance the Alberta Stroke Program Early Computed Tomography Score for Less Experienced Raters.
    Culbertson CJ; Christensen S; Mlynash M; Heit JJ; Federau C; Sells CM; Legault C; McCaslin AFH; Werbaneth K; Albers GW; Lansberg MG
    J Stroke Cerebrovasc Dis; 2020 Jul; 29(7):104820. PubMed ID: 32307316
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Automated versus manual imaging assessment of early ischemic changes in acute stroke: comparison of two software packages and expert consensus.
    Austein F; Wodarg F; Jürgensen N; Huhndorf M; Meyne J; Lindner T; Jansen O; Larsen N; Riedel C
    Eur Radiol; 2019 Nov; 29(11):6285-6292. PubMed ID: 31076862
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of automated and manual DWI-ASPECTS in acute ischemic stroke: total and region-specific assessment.
    Cheng X; Su X; Shi J; Liu Q; Zhou C; Dong Z; Xing W; Lu H; Pan C; Li X; Yu Y; Zhang L; Lu G
    Eur Radiol; 2021 Jun; 31(6):4130-4137. PubMed ID: 33247346
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Automated Calculation of the Alberta Stroke Program Early CT Score: Feasibility and Reliability.
    Maegerlein C; Fischer J; Mönch S; Berndt M; Wunderlich S; Seifert CL; Lehm M; Boeckh-Behrens T; Zimmer C; Friedrich B
    Radiology; 2019 Apr; 291(1):141-148. PubMed ID: 30720400
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Per-region interobserver agreement of Alberta Stroke Program Early CT Scores (ASPECTS).
    Nicholson P; Hilditch CA; Neuhaus A; Seyedsaadat SM; Benson JC; Mark I; Tsang COA; Schaafsma J; Kallmes DF; Krings T; Brinjikji W
    J Neurointerv Surg; 2020 Nov; 12(11):1069-1071. PubMed ID: 32024784
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Region-specific agreement in ASPECTS estimation between neuroradiologists and e-ASPECTS software.
    Neuhaus A; Seyedsaadat SM; Mihal D; Benson JC; Mark I; Kallmes DF; Brinjikji W
    J Neurointerv Surg; 2020 Jul; 12(7):720-723. PubMed ID: 31818971
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Performance of automated CT ASPECTS in comparison to physicians at different levels on evaluating acute ischemic stroke at a single institution in China.
    Huo X; Raynald ; Jin H; Yin Y; Yang G; Miao Z
    Chin Neurosurg J; 2021 Oct; 7(1):40. PubMed ID: 34593050
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Validation of two automated ASPECTS software on non-contrast computed tomography scans of patients with acute ischemic stroke.
    Chen Z; Shi Z; Lu F; Li L; Li M; Wang S; Wang W; Li Y; Luo Y; Tong D
    Front Neurol; 2023; 14():1170955. PubMed ID: 37090971
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Validation of automated Alberta Stroke Program Early CT Score (ASPECTS) software for detection of early ischemic changes on non-contrast brain CT scans.
    Wolff L; Berkhemer OA; van Es ACGM; van Zwam WH; Dippel DWJ; Majoie CBLM; van Walsum T; van der Lugt A;
    Neuroradiology; 2021 Apr; 63(4):491-498. PubMed ID: 32857212
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Automated ASPECTS on Noncontrast CT Scans in Patients with Acute Ischemic Stroke Using Machine Learning.
    Kuang H; Najm M; Chakraborty D; Maraj N; Sohn SI; Goyal M; Hill MD; Demchuk AM; Menon BK; Qiu W
    AJNR Am J Neuroradiol; 2019 Jan; 40(1):33-38. PubMed ID: 30498017
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.