These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

201 related articles for article (PubMed ID: 31975444)

  • 1. Clinical magnetic resonance imaging of arthroplasty at 1.5 T.
    Koff MF; Burge AJ; Potter HG
    J Orthop Res; 2020 Jul; 38(7):1455-1464. PubMed ID: 31975444
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Compressed Sensing SEMAC: 8-fold Accelerated High Resolution Metal Artifact Reduction MRI of Cobalt-Chromium Knee Arthroplasty Implants.
    Fritz J; Ahlawat S; Demehri S; Thawait GK; Raithel E; Gilson WD; Nittka M
    Invest Radiol; 2016 Oct; 51(10):666-76. PubMed ID: 27518214
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Magnetic Resonance Imaging Around Metal at 1.5 Tesla: Techniques From Basic to Advanced and Clinical Impact.
    Germann C; Nanz D; Sutter R
    Invest Radiol; 2021 Nov; 56(11):734-748. PubMed ID: 34074944
    [TBL] [Abstract][Full Text] [Related]  

  • 4. MR imaging of hip arthroplasty implants.
    Fritz J; Lurie B; Miller TT; Potter HG
    Radiographics; 2014; 34(4):E106-32. PubMed ID: 25019450
    [TBL] [Abstract][Full Text] [Related]  

  • 5. MRI after arthroplasty: comparison of MAVRIC and conventional fast spin-echo techniques.
    Hayter CL; Koff MF; Shah P; Koch KM; Miller TT; Potter HG
    AJR Am J Roentgenol; 2011 Sep; 197(3):W405-11. PubMed ID: 21862766
    [TBL] [Abstract][Full Text] [Related]  

  • 6. MRI of THA Correlates With Implant Wear and Tissue Reactions: A Cross-sectional Study.
    Koff MF; Esposito C; Shah P; Miranda M; Baral E; Fields K; Bauer T; Padgett DE; Wright T; Potter HG
    Clin Orthop Relat Res; 2019 Jan; 477(1):159-174. PubMed ID: 30499779
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Magnetic resonance imaging of joint replacements.
    Naraghi AM; White LM
    Semin Musculoskelet Radiol; 2006 Mar; 10(1):98-106. PubMed ID: 16514584
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Magnetic resonance imaging after total hip arthroplasty: evaluation of periprosthetic soft tissue.
    Potter HG; Nestor BJ; Sofka CM; Ho ST; Peters LE; Salvati EA
    J Bone Joint Surg Am; 2004 Sep; 86(9):1947-54. PubMed ID: 15342757
    [TBL] [Abstract][Full Text] [Related]  

  • 9. MR Imaging of Knee Arthroplasty Implants.
    Fritz J; Lurie B; Potter HG
    Radiographics; 2015; 35(5):1483-501. PubMed ID: 26295591
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Usefulness of slice encoding for metal artifact correction (SEMAC) technique for reducing metal artifacts after total knee arthroplasty.
    Jawhar A; Reichert M; Kostrzewa M; Nittka M; Attenberger U; Roehl H; Bludau F
    Eur J Orthop Surg Traumatol; 2019 Apr; 29(3):659-666. PubMed ID: 30310989
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Periprosthetic fractures: epidemiology and future projections.
    Della Rocca GJ; Leung KS; Pape HC
    J Orthop Trauma; 2011 Jun; 25 Suppl 2():S66-70. PubMed ID: 21566478
    [TBL] [Abstract][Full Text] [Related]  

  • 12. MR Imaging with Metal-suppression Sequences for Evaluation of Total Joint Arthroplasty.
    Talbot BS; Weinberg EP
    Radiographics; 2016; 36(1):209-25. PubMed ID: 26587889
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Advanced MR Imaging after Total Hip Arthroplasty: The Clinical Impact.
    Khodarahmi I; Fritz J
    Semin Musculoskelet Radiol; 2017 Nov; 21(5):616-629. PubMed ID: 29025190
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Metal Artifact Reduction Magnetic Resonance Imaging Around Arthroplasty Implants: The Negative Effect of Long Echo Trains on the Implant-Related Artifact.
    Kumar NM; de Cesar Netto C; Schon LC; Fritz J
    Invest Radiol; 2017 May; 52(5):310-316. PubMed ID: 28079703
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Compressed Sensing SEMAC MRI of Hip, Knee, and Ankle Arthroplasty Implants: A 1.5-T and 3-T Intrapatient Performance Comparison for Diagnosing Periprosthetic Abnormalities.
    Khodarahmi I; Khanuja HS; Stern SE; Carrino JA; Fritz J
    AJR Am J Roentgenol; 2023 Nov; 221(5):661-672. PubMed ID: 37255041
    [No Abstract]   [Full Text] [Related]  

  • 16. Adverse Events in the Treatment of Periprosthetic Fractures Around the Knee - a Clinical and Radiological Outcome Analysis.
    Schreiner AJ; Gonser C; Ihle C; Zauleck MK; Klopfer T; Stuby F; Stöckle U; Ochs BG
    Z Orthop Unfall; 2018 Jun; 156(3):287-297. PubMed ID: 29342496
    [TBL] [Abstract][Full Text] [Related]  

  • 17. MRI of total hip arthroplasty: technical aspects and imaging findings.
    Albano D; Pansa S; Messina C; Gitto S; Serpi F; Fusco S; Midiri F; Zagra L; Sconfienza LM
    Insights Imaging; 2024 Jun; 15(1):152. PubMed ID: 38900339
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Total knee arthroplasty MRI featuring slice-encoding for metal artifact correction: reduction of artifacts for STIR and proton density-weighted sequences.
    Sutter R; Hodek R; Fucentese SF; Nittka M; Pfirrmann CW
    AJR Am J Roentgenol; 2013 Dec; 201(6):1315-24. PubMed ID: 24261373
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Metal artifact reduction MRI of total ankle arthroplasty implants.
    de Cesar Netto C; Fonseca LF; Fritz B; Stern SE; Raithel E; Nittka M; Schon LC; Fritz J
    Eur Radiol; 2018 May; 28(5):2216-2227. PubMed ID: 29218618
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Advanced metal artifact reduction MRI of metal-on-metal hip resurfacing arthroplasty implants: compressed sensing acceleration enables the time-neutral use of SEMAC.
    Fritz J; Fritz B; Thawait GK; Raithel E; Gilson WD; Nittka M; Mont MA
    Skeletal Radiol; 2016 Oct; 45(10):1345-56. PubMed ID: 27497594
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.