BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

243 related articles for article (PubMed ID: 31975577)

  • 1. Investigation of light delivery geometries for photoacoustic applications using Monte Carlo simulations with multiple wavelengths, tissue types, and species characteristics.
    Sowers T; Yoon H; Emelianov S
    J Biomed Opt; 2020 Jan; 25(1):1-16. PubMed ID: 31975577
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Optimizing light delivery through fiber bundle in photoacoustic imaging with clinical ultrasound system: Monte Carlo simulation and experimental validation.
    Sivasubramanian K; Periyasamy V; Wen KK; Pramanik M
    J Biomed Opt; 2017 Apr; 22(4):41008. PubMed ID: 27997016
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Monte Carlo simulation of light transport in tissue for optimizing light delivery in photoacoustic imaging of the sentinel lymph node.
    Periyasamy V; Pramanik M
    J Biomed Opt; 2013 Oct; 18(10):106008. PubMed ID: 24108574
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Performance Characteristics of Photoacoustic Imaging Probes with Varying Frequencies and Light-delivery Schemes.
    Rich LJ; Chamberlain SR; Falcone DR; Bruce R; Heinmiller A; Xia J; Seshadri M
    Ultrason Imaging; 2019 Nov; 41(6):319-335. PubMed ID: 31570083
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Quantitative spectroscopic photoacoustic imaging: a review.
    Cox B; Laufer JG; Arridge SR; Beard PC
    J Biomed Opt; 2012 Jun; 17(6):061202. PubMed ID: 22734732
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Towards Transabdominal Functional Photoacoustic Imaging of the Placenta: Improvement in Imaging Depth Through Optimization of Light Delivery.
    Huda K; Swan KF; Gambala CT; Pridjian GC; Bayer CL
    Ann Biomed Eng; 2021 Aug; 49(8):1861-1873. PubMed ID: 33909192
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Modeling photoacoustic imaging with a scanning focused detector using Monte Carlo simulation of energy deposition.
    Paltauf G; Torke PR; Nuster R
    J Biomed Opt; 2018 Sep; 23(12):1-11. PubMed ID: 30251482
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Multidomain computational modeling of photoacoustic imaging: verification, validation, and image quality prediction.
    Akhlaghi N; Pfefer TJ; Wear KA; Garra BS; Vogt WC
    J Biomed Opt; 2019 Nov; 24(12):1-12. PubMed ID: 31705636
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Numerical study of reflectance imaging using a parallel Monte Carlo method.
    Chen C; Lu JQ; Li K; Zhao S; Brock RS; Hu XH
    Med Phys; 2007 Jul; 34(7):2939-48. PubMed ID: 17822002
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Experimental validation of Monte Carlo modeling of fluorescence in tissues in the UV-visible spectrum.
    Liu Q; Zhu C; Ramanujam N
    J Biomed Opt; 2003 Apr; 8(2):223-36. PubMed ID: 12683848
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Combination of virtual point detector concept and fluence compensation in acoustic resolution photoacoustic microscopy.
    Perekatova VV; Kirillin MY; Turchin IV; Subochev PV
    J Biomed Opt; 2018 Jul; 23(9):1-11. PubMed ID: 30066503
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Improvement of light penetration in biological tissue using an ultrasound-induced heating tunnel.
    Hsieh ZH; Fan CH; Ho YJ; Li ML; Yeh CK
    Sci Rep; 2020 Oct; 10(1):17406. PubMed ID: 33060643
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Adjustable Handheld Probe Design for Photoacoustic Imaging: Mathematical Modelling and Simulation Study.
    Zhao Y; Tao B; Yu S; Gao F
    Annu Int Conf IEEE Eng Med Biol Soc; 2019 Jul; 2019():6383-6386. PubMed ID: 31947303
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Three-dimensional quantitative photoacoustic tomography using an adjoint radiance Monte Carlo model and gradient descent.
    Buchmann J; Kaplan B; Powell S; Prohaska S; Laufer J
    J Biomed Opt; 2019 Jun; 24(6):1-13. PubMed ID: 31172727
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Compact and low-cost handheld quasibright-field linear-array probe design in photoacoustic computed tomography.
    Bai Y; Cong B; Gong X; Song L; Liu C
    J Biomed Opt; 2018 Sep; 23(12):1-10. PubMed ID: 30251485
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Acquiring photoacoustic signature of hematocrit variation from plexus layer of
    Banerjee S; Sarkar S; Karmakar S
    Biomed Phys Eng Express; 2021 Apr; 7(3):. PubMed ID: 33740772
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Monte Carlo simulation of light-tissue interaction: three-dimensional simulation for trans-illumination-based imaging of skin lesions.
    Patwardhan SV; Dhawan AP; Relue PA
    IEEE Trans Biomed Eng; 2005 Jul; 52(7):1227-36. PubMed ID: 16041986
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Tunable blood oxygenation in the vascular anatomy of a semi-anthropomorphic photoacoustic breast phantom.
    Dantuma M; Kruitwagen S; Ortega-Julia J; Pompe van Meerdervoort RP; Manohar S
    J Biomed Opt; 2021 Mar; 26(3):. PubMed ID: 33728828
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effects of skin tone on photoacoustic imaging and oximetry.
    Else TR; Hacker L; Gröhl J; Bunce EV; Tao R; Bohndiek SE
    J Biomed Opt; 2024 Jan; 29(Suppl 1):S11506. PubMed ID: 38125716
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Vascular contrast in narrow-band and white light imaging.
    Du Le VN; Wang Q; Gould T; Ramella-Roman JC; Pfefer TJ
    Appl Opt; 2014 Jun; 53(18):4061-71. PubMed ID: 24979441
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.