BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

267 related articles for article (PubMed ID: 31976797)

  • 1. Impact of nuchal cord on antenatal and intrapartum foetal heart rate surveillance and perinatal outcome.
    Tagliaferri S; Esposito FG; Esposito G; Saccone G; Signorini MG; Magenes G; Campanile M; Guida M; Zullo F
    J Obstet Gynaecol; 2020 Apr; 40(3):316-323. PubMed ID: 31976797
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Prevention of cerebral palsy during labour: role of foetal lactate.
    Borruto F; Comparetto C; Treisser A
    Arch Gynecol Obstet; 2008 Jul; 278(1):17-22. PubMed ID: 18071726
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Screening of foetal distress by assessment of umbilical cord lactate.
    Borruto F; Comparetto C; Wegher E; Treisser A
    Clin Exp Obstet Gynecol; 2006; 33(4):219-22. PubMed ID: 17211969
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Is nuchal cord justified as a cause of obstetrician anxiety?
    Narang Y; Vaid NB; Jain S; Suneja A; Guleria K; Faridi MM; Gupta B
    Arch Gynecol Obstet; 2014 Apr; 289(4):795-801. PubMed ID: 24190695
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Cardiotocography and perinatal outcome in women with and without meconium stained liquor.
    Odongo BE; Ndavi PM; Gachuno OW; Sequeira E
    East Afr Med J; 2010 May; 87(5):199-204. PubMed ID: 23057282
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Neonatal outcome and mode of delivery in the presence of nuchal cord loops: implications on patient counselling and the mode of delivery.
    Kong CW; Chan LW; To WW
    Arch Gynecol Obstet; 2015 Aug; 292(2):283-9. PubMed ID: 25631343
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Incidence of nuchal cord, mode of delivery and perinatal outcome: a notable experience in Dhulikhel Hospital - Kathmandu University Hospital.
    Tamrakar SR
    Nepal Med Coll J; 2013 Mar; 15(1):40-5. PubMed ID: 24592793
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Computerised analysis of antepartum foetal heart parameters: New reference ranges.
    Giuliano N; Annunziata ML; Esposito FG; Tagliaferri S; Di Lieto A; Magenes G; Signorini MG; Campanile M; Arduini D
    J Obstet Gynaecol; 2017 Apr; 37(3):296-304. PubMed ID: 27923290
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Cardiotocography in breech versus vertex delivery: an examiner-blinded, cross-sectional nested case-control study.
    Toivonen E; Palomäki O; Huhtala H; Uotila J
    BMC Pregnancy Childbirth; 2016 Oct; 16(1):319. PubMed ID: 27769196
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Relationship between computerized cardiotocography and perinatal outcomes].
    Liu W; Li X; Tang D
    Zhonghua Fu Chan Ke Za Zhi; 2001 Oct; 36(10):581-4. PubMed ID: 16134517
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Is short-term-variation of fetal-heart-rate a better predictor of fetal acidaemia in labour? A feasibility study.
    Kapaya H; Jacques R; Almond T; Rosser MH; Anumba D
    PLoS One; 2020; 15(8):e0236982. PubMed ID: 32745099
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Fetal heart rate parameters and perinatal outcomes in fetuses with nuchal cords.
    Hoh JK; Sung YM; Park MI
    J Obstet Gynaecol Res; 2012 Feb; 38(2):358-63. PubMed ID: 22176493
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Manual fetal stimulation during intrapartum fetal surveillance: a randomized controlled trial.
    Tahmina S; Daniel M; Krishnan L
    Am J Obstet Gynecol MFM; 2022 Mar; 4(2):100574. PubMed ID: 35051669
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Placental dysfunction in uncomplicated and complicated intrauterine growth restriction by preeclampsia and neonatal outcome.
    Tagliaferri S; Travaglino A; Raffone A; Saccone G; Campanino MR; Zara G; Ammendola A; Pini N; Maruotti GM; Magenes G; Signorini MG; Guida M; Zullo F; D'Armiento M; Campanile M
    J Matern Fetal Neonatal Med; 2022 Dec; 35(25):8169-8175. PubMed ID: 34470111
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Physiological CTG interpretation: the significance of baseline fetal heart rate changes after the onset of decelerations and associated perinatal outcomes.
    Jia YJ; Chen X; Cui HY; Whelehan V; Archer A; Chandraharan E
    J Matern Fetal Neonatal Med; 2021 Jul; 34(14):2349-2354. PubMed ID: 31533502
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Foetal compromise by spontaneous foetal heart rate deceleration in reactive non-stress test and decreased amniotic fluid index.
    Begum F; Buckshee K
    Bangladesh Med Res Counc Bull; 1998 Dec; 24(3):60-6. PubMed ID: 10874369
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The development and validation of an algorithm for real-time computerised fetal heart rate monitoring in labour.
    Taylor GM; Mires GJ; Abel EW; Tsantis S; Farrell T; Chien PF; Liu Y
    BJOG; 2000 Sep; 107(9):1130-7. PubMed ID: 11002957
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Birth asphyxia and hypoxic ischemic encephalopathy, incidence and obstetric risk factors].
    Palsdottir K; Dagbjartsson A; Thorkelsson T; Hardardottir H
    Laeknabladid; 2007 Sep; 93(9):595-601. PubMed ID: 17823499
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Fetal heart rate monitoring and neonatal outcome in a population of early- and late-onset intrauterine growth restriction.
    Esposito FG; Tagliaferri S; Giudicepietro A; Giuliano N; Maruotti GM; Saccone G; Signorini MG; Magenes G; Campanile M; Zullo F
    J Obstet Gynaecol Res; 2019 Jul; 45(7):1343-1351. PubMed ID: 31099119
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Basic principles of the foetal heart rate during delivery without hypoxia and acidosis.
    Roemer VM; Walden R
    Z Geburtshilfe Neonatol; 2012 Feb; 216(1):11-21. PubMed ID: 22331523
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.