These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
361 related articles for article (PubMed ID: 31981877)
21. Compressed Sensing for Breast MRI: Resolving the Trade-Off Between Spatial and Temporal Resolution. Vreemann S; Rodriguez-Ruiz A; Nickel D; Heacock L; Appelman L; van Zelst J; Karssemeijer N; Weiland E; Maas M; Moy L; Kiefer B; Mann RM Invest Radiol; 2017 Oct; 52(10):574-582. PubMed ID: 28463932 [TBL] [Abstract][Full Text] [Related]
22. Diffusion-Weighted Imaging With Apparent Diffusion Coefficient Mapping for Breast Cancer Detection as a Stand-Alone Parameter: Comparison With Dynamic Contrast-Enhanced and Multiparametric Magnetic Resonance Imaging. Pinker K; Moy L; Sutton EJ; Mann RM; Weber M; Thakur SB; Jochelson MS; Bago-Horvath Z; Morris EA; Baltzer PA; Helbich TH Invest Radiol; 2018 Oct; 53(10):587-595. PubMed ID: 29620604 [TBL] [Abstract][Full Text] [Related]
23. Ultrafast Dynamic Contrast-Enhanced MRI Using Compressed Sensing: Associations of Early Kinetic Parameters With Prognostic Factors of Breast Cancer. Kim JJ; Kim JY; Hwangbo L; Suh HB; Son Y; Nickel MD; Grimm R AJR Am J Roentgenol; 2021 Jul; 217(1):56-63. PubMed ID: 33909465 [No Abstract] [Full Text] [Related]
24. Kinetic Analysis of Benign and Malignant Breast Lesions With Ultrafast Dynamic Contrast-Enhanced MRI: Comparison With Standard Kinetic Assessment. Abe H; Mori N; Tsuchiya K; Schacht DV; Pineda FD; Jiang Y; Karczmar GS AJR Am J Roentgenol; 2016 Nov; 207(5):1159-1166. PubMed ID: 27532897 [TBL] [Abstract][Full Text] [Related]
25. Diffusion tensor imaging for characterizing tumor microstructure and improving diagnostic performance on breast MRI: a prospective observational study. Luo J; Hippe DS; Rahbar H; Parsian S; Rendi MH; Partridge SC Breast Cancer Res; 2019 Sep; 21(1):102. PubMed ID: 31484577 [TBL] [Abstract][Full Text] [Related]
26. Comparison of conventional DCE-MRI and a novel golden-angle radial multicoil compressed sensing method for the evaluation of breast lesion conspicuity. Heacock L; Gao Y; Heller SL; Melsaether AN; Babb JS; Block TK; Otazo R; Kim SG; Moy L J Magn Reson Imaging; 2017 Jun; 45(6):1746-1752. PubMed ID: 27859874 [TBL] [Abstract][Full Text] [Related]
27. Differentiation between malignant and benign breast masses: combination of semi-quantitative analysis on DCE-MRI and histogram analysis of ADC maps. Liu HL; Zong M; Wei H; Lou JJ; Wang SQ; Zou QG; Shi HB; Jiang YN Clin Radiol; 2018 May; 73(5):460-466. PubMed ID: 29295753 [TBL] [Abstract][Full Text] [Related]
28. Ultrafast Dynamic Contrast-Enhanced Breast MRI: Lesion Conspicuity and Size Assessment according to Background Parenchymal Enhancement. Kim SY; Cho N; Choi Y; Shin SU; Kim ES; Lee SH; Chang JM; Moon WK Korean J Radiol; 2020 May; 21(5):561-571. PubMed ID: 32323501 [TBL] [Abstract][Full Text] [Related]
29. Potential of Noncontrast Magnetic Resonance Imaging With Diffusion-Weighted Imaging in Characterization of Breast Lesions: Intraindividual Comparison With Dynamic Contrast-Enhanced Magnetic Resonance Imaging. Baltzer PAT; Bickel H; Spick C; Wengert G; Woitek R; Kapetas P; Clauser P; Helbich TH; Pinker K Invest Radiol; 2018 Apr; 53(4):229-235. PubMed ID: 29190227 [TBL] [Abstract][Full Text] [Related]
30. Ultrafast Dynamic Contrast-enhanced MRI of the Breast: How Is It Used? Kataoka M; Honda M; Ohashi A; Yamaguchi K; Mori N; Goto M; Fujioka T; Mori M; Kato Y; Satake H; Iima M; Kubota K Magn Reson Med Sci; 2022 Mar; 21(1):83-94. PubMed ID: 35228489 [TBL] [Abstract][Full Text] [Related]
31. Ultrafast Dynamic Contrast-Enhanced MRI of the Breast: From Theory to Practice. Kataoka M; Honda M; Sagawa H; Ohashi A; Sakaguchi R; Hashimoto H; Iima M; Takada M; Nakamoto Y J Magn Reson Imaging; 2024 Aug; 60(2):401-416. PubMed ID: 38085134 [TBL] [Abstract][Full Text] [Related]
32. Impact of the Number of Iterations in Compressed Sensing Reconstruction on Ultrafast Dynamic Contrast-enhanced Breast MR Imaging. Sagawa H; Kataoka M; Kanao S; Onishi N; Nickel MD; Toi M; Togashi K Magn Reson Med Sci; 2019 Jul; 18(3):200-207. PubMed ID: 30416179 [TBL] [Abstract][Full Text] [Related]
33. Abbreviated breast MRI combining FAST protocol and high temporal resolution (HTR) dynamic contrast enhanced (DCE) sequence. Milon A; Vande Perre S; Poujol J; Trop I; Kermarrec E; Bekhouche A; Thomassin-Naggara I Eur J Radiol; 2019 Aug; 117():199-208. PubMed ID: 31307648 [TBL] [Abstract][Full Text] [Related]
34. Differentiation of Benign from Malignant Adnexal Masses by Dynamic Contrast-Enhanced MRI (DCE-MRI): Quantitative and Semi-quantitative analysis at 3-Tesla MRI. Gity M; Parviz S; Saligheh Rad H; Fathi Kazerooni A; Shirali E; Shakiba M; Baikpour M Asian Pac J Cancer Prev; 2019 Apr; 20(4):1073-1079. PubMed ID: 31030476 [TBL] [Abstract][Full Text] [Related]
35. The utility of ultrafast MRI and conventional DCE-MRI for predicting histologic aggressiveness in patients with breast cancer. Kim SG; Park AY; Jung HK; Ko KH; Kim Y Acta Radiol; 2024 Oct; 65(10):1186-1195. PubMed ID: 39295306 [TBL] [Abstract][Full Text] [Related]
36. Artificial Intelligence-Based Classification of Breast Lesions Imaged With a Multiparametric Breast MRI Protocol With Ultrafast DCE-MRI, T2, and DWI. Dalmiş MU; Gubern-Mérida A; Vreemann S; Bult P; Karssemeijer N; Mann R; Teuwen J Invest Radiol; 2019 Jun; 54(6):325-332. PubMed ID: 30652985 [TBL] [Abstract][Full Text] [Related]
37. Performance evaluation of texture analysis based on kinetic parametric maps from breast DCE-MRI in classifying benign from malignant lesions. Jiang Z; Yin J J Surg Oncol; 2020 Jun; 121(8):1181-1190. PubMed ID: 32167588 [TBL] [Abstract][Full Text] [Related]
38. Assessing the performance of benign and malignant breast lesion classification with bilateral TIC differentiation and other effective features in DCE-MRI. Li H; Sun H; Liu S; Zhang W; Arukalam FM; Ma H; Qian W J Magn Reson Imaging; 2019 Aug; 50(2):465-473. PubMed ID: 30688398 [TBL] [Abstract][Full Text] [Related]
39. Ultrafast Bilateral DCE-MRI of the Breast with Conventional Fourier Sampling: Preliminary Evaluation of Semi-quantitative Analysis. Pineda FD; Medved M; Wang S; Fan X; Schacht DV; Sennett C; Oto A; Newstead GM; Abe H; Karczmar GS Acad Radiol; 2016 Sep; 23(9):1137-44. PubMed ID: 27283068 [TBL] [Abstract][Full Text] [Related]
40. Maximum slope using ultrafast breast DCE-MRI at 1.5 Tesla: a potential tool for predicting breast lesion aggressiveness. Pelissier M; Ambarki K; Salleron J; Henrot P Eur Radiol; 2021 Dec; 31(12):9556-9566. PubMed ID: 34117556 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]