These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
120 related articles for article (PubMed ID: 31982340)
41. Accuracy of Smartphone-Based Pulse Oximetry Compared with Hospital-Grade Pulse Oximetry in Healthy Children. Tomlinson S; Behrmann S; Cranford J; Louie M; Hashikawa A Telemed J E Health; 2018 Jul; 24(7):527-535. PubMed ID: 29215972 [TBL] [Abstract][Full Text] [Related]
42. Effect of local limb temperature on pulse oximetry and the plethysmographic pulse wave. Schramm WM; Bartunek A; Gilly H Int J Clin Monit Comput; 1997 Feb; 14(1):17-22. PubMed ID: 9127780 [TBL] [Abstract][Full Text] [Related]
43. Pulse oximetry during lumbar epidural anesthesia: reliability of values measured at the hand and the foot. Peduto VA; Tani R; Pani S Anesth Analg; 1994 May; 78(5):921-4. PubMed ID: 8160991 [TBL] [Abstract][Full Text] [Related]
44. Pulse oximetry in horses. Whitehair KJ; Watney GC; Leith DE; Debowes RM Vet Surg; 1990; 19(3):243-8. PubMed ID: 2349781 [TBL] [Abstract][Full Text] [Related]
45. [Evaluation of circulatory state using pulse oximeter: 2. PI (perfusion index) x PVI (pleth variability index)]. Kaneda T; Suzuki T Masui; 2009 Jul; 58(7):860-5. PubMed ID: 19618827 [TBL] [Abstract][Full Text] [Related]
46. Accuracy of pulse oximetry in the intensive care unit. Van de Louw A; Cracco C; Cerf C; Harf A; Duvaldestin P; Lemaire F; Brochard L Intensive Care Med; 2001 Oct; 27(10):1606-13. PubMed ID: 11685301 [TBL] [Abstract][Full Text] [Related]
47. [Transesophageal arterial oxygen saturation monitoring: an experimental study]. Zhu ZQ; Wei W; Yang ZB; Liu AJ; Liu J Sichuan Da Xue Xue Bao Yi Xue Ban; 2005 Jan; 36(1):124-6. PubMed ID: 15702800 [TBL] [Abstract][Full Text] [Related]
48. Comparison of Transmittance and Reflectance Pulse Oximetry in Anesthetized Dogs. Nixdorff J; Zablotski Y; Hartmann K; Dörfelt R Front Vet Sci; 2021; 8():643966. PubMed ID: 33996971 [No Abstract] [Full Text] [Related]
49. Detection of Pulpal Blood Flow In Vivo with Pulse Oximetry in Dogs. Riehl J; Hetzel SJ; Snyder CJ; Soukup JW Front Vet Sci; 2016; 3():36. PubMed ID: 27243024 [TBL] [Abstract][Full Text] [Related]
50. Accuracy of pulse oximetry in hypothermic neonates and infants undergoing cardiac surgery. Iyer P; McDougall P; Loughnan P; Mee RB; Al-Tawil K; Carlin J Crit Care Med; 1996 Mar; 24(3):507-11. PubMed ID: 8625642 [TBL] [Abstract][Full Text] [Related]
51. [The pulmonary arterial oxygen saturation monitoring via trachea in hypoxia dogs]. Gong Q; Wang L; Wei W; Yang Z; Mou L; Liu Q Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2009 Aug; 26(4):752-6. PubMed ID: 19813603 [TBL] [Abstract][Full Text] [Related]
53. Evaluation of pulse oximetry in anesthetized dogs. Nishimura R; Kim H; Matsunaga S; Sasaki N; Takeuchi A J Vet Med Sci; 1991 Dec; 53(6):1117-8. PubMed ID: 1790228 [No Abstract] [Full Text] [Related]
54. Reference values of capillary blood saturation in neonates and its difference from pulse oximetry. Jesić MM; Jesić MD; Krstajić TD; Vujnović ZM; Cutura ND; Maglajlić SS Srp Arh Celok Lek; 2010; 138(5-6):297-9. PubMed ID: 20607971 [TBL] [Abstract][Full Text] [Related]
55. Noninvasive oximetry in the rat. Decker MJ; Conrad KP; Strohl KP Biomed Instrum Technol; 1989; 23(3):222-8. PubMed ID: 2752232 [TBL] [Abstract][Full Text] [Related]
56. Desaturation times between dogs preoxygenated via face mask or flow-by technique before induction of anesthesia. Ambros B; Carrozzo MV; Jones T Vet Anaesth Analg; 2018 Jul; 45(4):452-458. PubMed ID: 29739649 [TBL] [Abstract][Full Text] [Related]
57. Skin reflectance pulse oximetry: in vivo measurements from the forearm and calf. Mendelson Y; McGinn MJ J Clin Monit; 1991 Jan; 7(1):7-12. PubMed ID: 1999702 [TBL] [Abstract][Full Text] [Related]
58. Devepopment of an optical probe to investigate the suitability of measuring photoplethysmographs and blood oxygen saturation from the human auditory canal. Budidha K; Kyriacou PA Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():1736-9. PubMed ID: 24110042 [TBL] [Abstract][Full Text] [Related]
59. Variability in estimating shunt from single pulse oximetry measurements. Karlen W; Petersen CL; Dumont GA; Ansermino JM Physiol Meas; 2015 May; 36(5):967-81. PubMed ID: 25856630 [TBL] [Abstract][Full Text] [Related]
60. Design and evaluation of a new reflectance pulse oximeter sensor. Mendelson Y; Kent JC; Yocum BL; Birle MJ Med Instrum; 1988 Aug; 22(4):167-73. PubMed ID: 3173170 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]