These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

123 related articles for article (PubMed ID: 31983793)

  • 1. In Situ Chemically-Selective Monitoring of Multiphase Displacement Processes in a Carbonate Rock Using 3D Magnetic Resonance Imaging.
    Ramskill NP; Sederman AJ; Mantle MD; Appel M; de Jong H; Gladden LF
    Transp Porous Media; 2018; 121(1):15-35. PubMed ID: 31983793
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Identification of sampling patterns for high-resolution compressed sensing MRI of porous materials: 'learning' from X-ray microcomputed tomography data.
    Karlsons K; DE Kort DW; Sederman AJ; Mantle MD; DE Jong H; Appel M; Gladden LF
    J Microsc; 2019 Nov; 276(2):63-81. PubMed ID: 31587277
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Fast imaging of laboratory core floods using 3D compressed sensing RARE MRI.
    Ramskill NP; Bush I; Sederman AJ; Mantle MD; Benning M; Anger BC; Appel M; Gladden LF
    J Magn Reson; 2016 Sep; 270():187-197. PubMed ID: 27500742
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Mapping three-dimensional oil distribution with π-EPI MRI measurements at low magnetic field.
    Li M; Xiao D; Romero-Zerón L; Marica F; MacMillan B; Balcom BJ
    J Magn Reson; 2016 Aug; 269():13-23. PubMed ID: 27208417
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Under-sampling and compressed sensing of 3D spatially-resolved displacement propagators in porous media using APGSTE-RARE MRI.
    de Kort DW; Hertel SA; Appel M; de Jong H; Mantle MD; Sederman AJ; Gladden LF
    Magn Reson Imaging; 2019 Feb; 56():24-31. PubMed ID: 30337126
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Quantification of oil and water in preserved reservoir rock by NMR spectroscopy and imaging.
    Davies S; Hardwick A; Roberts D; Spowage K; Packer KJ
    Magn Reson Imaging; 1994; 12(2):349-53. PubMed ID: 8170337
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Real-time oil-saturation monitoring in rock cores with low-field NMR.
    Mitchell J; Howe AM; Clarke A
    J Magn Reson; 2015 Jul; 256():34-42. PubMed ID: 25996514
    [TBL] [Abstract][Full Text] [Related]  

  • 8. NMR imaging of fluid dynamics in reservoir core.
    Baldwin BA; Yamanashi WS
    Magn Reson Imaging; 1988; 6(5):493-500. PubMed ID: 3226235
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Experimental investigation on spontaneous counter-current imbibition in water-wet natural reservoir sandstone core using MRI.
    Zhao Y; Song Y
    Magn Reson Chem; 2017 Jun; 55(6):546-552. PubMed ID: 27943423
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Imaging of multiphase fluid saturation within a porous material via sodium NMR.
    Washburn KE; Madelin G
    J Magn Reson; 2010 Jan; 202(1):122-6. PubMed ID: 19864169
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Monitoring bacterially induced calcite precipitation in porous media using magnetic resonance imaging and flow measurements.
    Sham E; Mantle MD; Mitchell J; Tobler DJ; Phoenix VR; Johns ML
    J Contam Hydrol; 2013 Sep; 152():35-43. PubMed ID: 23872026
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Quantitative NMR imaging of multiphase flow in porous media.
    Chen S; Kim KH; Qin F; Watson AT
    Magn Reson Imaging; 1992; 10(5):815-26. PubMed ID: 1461077
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Characterizing pore-scale structure-flow correlations in sedimentary rocks using magnetic resonance imaging.
    Karlsons K; de Kort DW; Sederman AJ; Mantle MD; Freeman JJ; Appel M; Gladden LF
    Phys Rev E; 2021 Feb; 103(2-1):023104. PubMed ID: 33736007
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Monitoring oil displacement processes with k-t accelerated spin echo SPI.
    Li M; Xiao D; Romero-Zerón L; Balcom BJ
    Magn Reson Chem; 2016 Mar; 54(3):197-204. PubMed ID: 26626141
    [TBL] [Abstract][Full Text] [Related]  

  • 15. k-t acceleration in pure phase encode MRI to monitor dynamic flooding processes in rock core plugs.
    Xiao D; Balcom BJ
    J Magn Reson; 2014 Jun; 243():114-21. PubMed ID: 24809307
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Study of the fluid flow characteristics in a porous medium for CO2 geological storage using MRI.
    Song Y; Jiang L; Liu Y; Yang M; Zhou X; Zhao Y; Dou B; Abudula A; Xue Z
    Magn Reson Imaging; 2014 Jun; 32(5):574-84. PubMed ID: 24674025
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Quantitative determination of porosity: a local assessment by NMR imaging techniques.
    Borgia GC; Bortolotti V; Dattilo P; Fantazzini P; Maddinelli G
    Magn Reson Imaging; 1996; 14(7-8):919-21. PubMed ID: 8970110
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Spin echo SPI methods for quantitative analysis of fluids in porous media.
    Li L; Han H; Balcom BJ
    J Magn Reson; 2009 Jun; 198(2):252-60. PubMed ID: 19307140
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Accelerating flow propagator measurements for the investigation of reactive transport in porous media.
    Colbourne AA; Sederman AJ; Mantle MD; Gladden LF
    J Magn Reson; 2016 Nov; 272():68-72. PubMed ID: 27662402
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Technical Note: Real-time 3D MRI in the presence of motion for MRI-guided radiotherapy: 3D Dynamic keyhole imaging with super-resolution.
    Kim T; Park JC; Gach HM; Chun J; Mutic S
    Med Phys; 2019 Oct; 46(10):4631-4638. PubMed ID: 31376292
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.