These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

133 related articles for article (PubMed ID: 31992671)

  • 1. The Site of Oxygen Delivery Into a Home Ventilator Affects Recorded Volumes.
    d'Aranda E; Cungi PJ; Mathais Q; Cardinal M; Esnault P; Nguyen C; Bordes J; Meaudre E; Goutorbe P
    Respir Care; 2020 Mar; 65(3):288-292. PubMed ID: 31992671
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effect of leak and breathing pattern on the accuracy of tidal volume estimation by commercial home ventilators: a bench study.
    Luján M; Sogo A; Pomares X; Monsó E; Sales B; Blanch L
    Respir Care; 2013 May; 58(5):770-7. PubMed ID: 23051878
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Effects of aerosol inhalation on respiratory mechanical parameters under different ventilation patterns and ventilator parameters].
    Wang L; Guan C; Qin X; Qu Y
    Zhonghua Wei Zhong Bing Ji Jiu Yi Xue; 2018 Nov; 30(11):1036-1040. PubMed ID: 30541641
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Maximizing oxygen delivery during mechanical ventilation with a portable oxygen concentrator.
    Rodriquez D; Blakeman TC; Dorlac W; Johannigman JA; Branson RD
    J Trauma; 2010 Jul; 69 Suppl 1():S87-93. PubMed ID: 20622626
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Monitoring of noninvasive ventilation by built-in software of home bilevel ventilators: a bench study.
    Contal O; Vignaux L; Combescure C; Pepin JL; Jolliet P; Janssens JP
    Chest; 2012 Feb; 141(2):469-476. PubMed ID: 21778253
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Reliability of Displayed Tidal Volume in Healthy and Surfactant-Depleted Piglets.
    Mendiondo Luedloff AC; Thurman TL; Holt SJ; Bai S; Heulitt MJ; Courtney SE
    Respir Care; 2016 Dec; 61(12):1605-1612. PubMed ID: 27899539
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Reliability of Tidal Volume in Average Volume Assured Pressure Support Mode.
    Stagnara A; Baboi L; Nesme P; Subtil F; Louis B; Guérin C
    Respir Care; 2018 Sep; 63(9):1139-1146. PubMed ID: 29921607
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of dynamic random leaks on the monitoring accuracy of home mechanical ventilators: a bench study.
    Sogo A; Montanyà J; Monsó E; Blanch L; Pomares X; Lujàn M
    BMC Pulm Med; 2013 Dec; 13():75. PubMed ID: 24325396
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Harms of unintentional leaks during volume targeted pressure support ventilation.
    Khirani S; Louis B; Leroux K; Delord V; Fauroux B; Lofaso F
    Respir Med; 2013 Jul; 107(7):1021-9. PubMed ID: 23643316
    [TBL] [Abstract][Full Text] [Related]  

  • 10. FLOW-i ventilator performance in the presence of a circle system leak.
    Lucangelo U; Ajčević M; Accardo A; Borelli M; Peratoner A; Comuzzi L; Zin WA
    J Clin Monit Comput; 2017 Apr; 31(2):273-280. PubMed ID: 27062381
    [TBL] [Abstract][Full Text] [Related]  

  • 11. In vivo physiologic comparison of two ventilators used for domiciliary ventilation in children with cystic fibrosis.
    Fauroux B; Pigeot J; Polkey MI; Isabey D; Clément A; Lofaso F
    Crit Care Med; 2001 Nov; 29(11):2097-105. PubMed ID: 11700403
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Accuracy of Delivery and Effects on Absolute Humidity of Low Tidal Volume by ICU Ventilators.
    Moro B; Baboi L; Yonis H; Subtil F; Louis B; Guérin C
    Respir Care; 2018 Oct; 63(10):1253-1263. PubMed ID: 29945908
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A laboratory evaluation of 2 mechanical ventilators in the presence of helium-oxygen mixtures.
    Brown MK; Willms DC
    Respir Care; 2005 Mar; 50(3):354-60. PubMed ID: 15737245
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Higher Fresh Gas Flow Rates Decrease Tidal Volume During Pressure Control Ventilation.
    Mohammad S; Gravenstein N; Gonsalves D; Vasilopoulos T; Lampotang S
    Anesth Analg; 2017 May; 124(5):1506-1511. PubMed ID: 28333703
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Performance of Leak Compensation in All-Age ICU Ventilators During Volume-Targeted Neonatal Ventilation: A Lung Model Study.
    Itagaki T; Bennett DJ; Chenelle CT; Fisher DF; Kacmarek RM
    Respir Care; 2017 Jan; 62(1):10-21. PubMed ID: 27879380
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A bench evaluation of fraction of oxygen in air delivery and tidal volume accuracy in home care ventilators available for hospital use.
    Baboi L; Subtil F; Guérin C
    J Thorac Dis; 2016 Dec; 8(12):3639-3647. PubMed ID: 28149559
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Influence of tidal volume, respiratory rate, and supplemental oxygen flow on delivered oxygen fraction using a mouth to mask ventilation device.
    Palmisano JM; Moler FW; Galura C; Gordon M; Custer JR
    J Emerg Med; 1993; 11(6):685-9. PubMed ID: 8157905
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Accuracy of tidal volume delivery by five different models of large-animal ventilators.
    Floriano D; Hopster K; Driessen B
    Am J Vet Res; 2020 Nov; 81(11):857-864. PubMed ID: 33107749
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Reduction of Endotracheal Tube Connector Dead Space Improves Ventilation: A Bench Test on a Model Lung Simulating an Extremely Low Birth Weight Neonate.
    Ivanov VA
    Respir Care; 2016 Feb; 61(2):155-61. PubMed ID: 26577200
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Do new anesthesia ventilators deliver small tidal volumes accurately during volume-controlled ventilation?
    Bachiller PR; McDonough JM; Feldman JM
    Anesth Analg; 2008 May; 106(5):1392-400, table of contents. PubMed ID: 18420850
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.